Abstract
For many cochlear implant (CI) users, frequency discrimination is still challenging. We studied the effect of frequency differences relative to the electrode frequency bands on pure tone discrimination. A single-center, prospective, controlled, psychoacoustic exploratory study was conducted in a tertiary university referral center. Thirty-four patients with Cochlear Ltd. and MED-EL CIs and 19 age-matched normal-hearing control subjects were included. Two sinusoidal tones were presented with varying frequency differences. The reference tone frequency was chosen according to the center frequency of basal or apical electrodes. Discrimination abilities were psychophysically measured in a three-interval, two-alternative, forced-choice procedure (3I-2AFC) for various CI electrodes. Hit rates were measured, particularly with respect to discrimination abilities at the corner frequency of the electrode frequency-bands. The mean rate of correct decision concerning pitch difference was about 60% for CI users and about 90% for the normal-hearing control group. In CI users, the difference limen was two semitones, while normal-hearing participants detected the difference of one semitone. No influence of the corner frequency of the CI electrodes was found. In CI users, pure tone discrimination seems to be independent of tone positions relative to the corner frequency of the electrode frequency-band. Differences of 2 semitones can be distinguished within one electrode.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Department of Otorhinolaryngology, Head and Neck Surgery, Halle (Saale), Germany (GRID:grid.461820.9) (ISNI:0000 0004 0390 1701); Universitätsklinikum Halle (Saale), HNO-Klinik, Halle (Saale), Germany (GRID:grid.461820.9) (ISNI:0000 0004 0390 1701)
2 University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Department of Otorhinolaryngology, Head and Neck Surgery, Halle (Saale), Germany (GRID:grid.461820.9) (ISNI:0000 0004 0390 1701)