1 Introduction
At a global scale, mineral dust or mineral aerosols could represent about 40 % of the total amount of particles injected into the atmosphere each year . Studying atmospheric mineral dust, which modifies atmospheric radiation and alters cloud properties, thus impacting climate, is essential to better understand the evolution of Earth's climate system
In source regions of dry erodible material, high local wind speeds can move the largest and heaviest coarse soil particles (between 50 and 200 in diameter) on the soil surface, while the smaller particles (less than 70 in diameter) move by saltation, a jumping movement near the soil surface. Collisions between these particles and aggregates of the finest particles present at the soil surface release a large spectrum of smaller particles into the air . These fine particles, particularly those smaller than 10 in diameter (), can be transported by wind at higher altitudes over long distances . These particles are also a key parameter in air quality control .
Efforts are made in atmospheric sciences to develop devices able to prevent unwanted collection of the largest particles with a 10 cut-off diameter. Commercially available standard sampling devices are commonly used to collect fine particles. One of the most popular is the sampling head, where size segregation is obtained by removal of the largest particles through impaction on an aluminium alloy plate. This process may however contaminate aerosol samples with metal particles because of friction between coarse particles and the metallic parts of the system. This is not an issue for simple aerosol mass determination but could generate problems if the objective is to define the chemical composition of airborne particles. It is well known that impactor inlet systems must be cleaned regularly: deposited particles that do not stick well on the impaction surface can bounce or can be de-agglomerated and re-entrained downstream, leading to oversampling . Among other aerosol sampling head systems is the cyclone sampling device, where particles are separated by centrifugal force. Cyclone walls may be made of glass instead of metal, thus reducing potential secondary emission effects. This system is nevertheless difficult to manage because of its sensitivity to air pump flow rate . Impinger systems present a liquid impaction surface and are well adapted for bio-aerosols but not for mineral particles. In this study, the potential of a new sampling head is evaluated in terms of mass collection efficiency and chemical composition accuracy. This new inlet uses the decantation principle; it can be built at low cost, using local materials because of its simple design and the broad availability of its components. Particle separation in this 125 diameter vertical tube decanter (VTD) system is based on gravitational settling counteracted by upward airflow. This system prevents collision between airborne particles and aerosol collector surfaces, so that sample contamination by metallic surface abrasion is minimized.
Source regions are good places to test possible biases introduced by the sampling head device in fine aerosol sampling because coarse aerosols larger than 10 are often present. Differences in cut-off diameter tuning will lead to differences in aerosol sample mass and chemical composition, as different amounts of the coarse particles present in the source zone will be collected. It is for this reason that we decided to compare the performance of two different sampling heads in a dry region of Tunisia. Aerosol chemical composition, including rare earth elements (REEs), and mass concentration of aerosols were measured at the same time using two sampling devices: a newly designed stainless steel decanter, VTD, and a brand-new aluminium alloy commercial sampling head (hereafter PM10), both operating at a flow rate of about 1 . The chosen sampling station is part of the International Network to study Deposition and Atmospheric composition in AFrica (INDAAF) and is equipped with a reference instrument for mass concentration measurements, a automatic weighing device (tapered element oscillating microbalance, TEOM). Masses deduced from elemental analysis of samples collected by each device were compared with one another and also with this third system, operating within the same flow rate range. The objective of this paper is to show that a low-cost decanter tube can replace an impaction-based sampling head for proper aerosol sampling. To achieve this objective, we use compositional data analysis (CoDA), an innovative tool for geochemical data analyses.
2 Materials and methods
2.1 Aerosol sampling and direct measurements
A total of 16 paired samples were collected during a 2-week field experiment, at the Institut des Régions Arides campus, 20 north of the city of Medenine, Tunisia. The collection site (332958.62 N–103835.2 E), surrounded by dry lands, is 5 south-west of the Boughrara Gulf. The two sampling devices were fixed to the roof of the highest building on campus, about 20 Both the VTD and PM10 were attached to a tubular stand, with a distance of about 30 between them (Fig. ), to facilitate comparison of results. Aerosol samples were collected continuously from 29 March 2016 to 7 April 2016 using polysulfone open-face 47 filter holders (Nalgene®) and mixed cellulose ester filters, with a pore size of 0.45 (Whatman®). The filters were changed twice a day for each device at the same time: around 08:30 and 19:30, except for the pair YX29/30, which was exposed for 24 h.
Figure 1
From left to right, the VTD system, the PM10 sampling head, and the TEOM. Both the TEOM and PM10 heads are from the same brand: Tecora™ PM10.
[Figure omitted. See PDF]
Figure 2
Internal structure of sampling head.
[Figure omitted. See PDF]
Figure 3
The VTD system. (a) VTD installation on the roof of the building. (b) Two bottom-up views of filter on filter holder inside the decanter tube. (c) Diagram of decantation system.
[Figure omitted. See PDF]
Figure shows the internal structure of the commercial PM10 sampling head (Tecora, Paris, France) installed, for the present study, with an aluminium alloy sampling plate. In the VTD system installed beside it (Fig. ), air is pumped at the top of the tube and enters from the bottom of the tube. Fine particles are dragged upwards by the airflow and collected by the filter, but the largest particles do not reach the filter because of their weight. The terminal settling velocity for a particle of diameter in a gravitational field is calculated using Stokes' law
When a particle is in the upward airflow, it is pulled up unless its gravitational settling velocity is greater than the airflow velocity, in which case it will settle down. A cut-off point occurs when gravitational velocity is equal to air velocity: only particles smaller than this cut-off size can reach the top of the VTD system and thus be collected on the filter. With a flow rate of 1 , the Reynolds number is equal to 50 inside the VTD. A laminar flow can be assumed and therefore a constant air velocity in the tube. The steady-state settling velocity of a particle is then reached when where is the upward air velocity, is the pumped air flux, and is the radius of the cylindrical VTD system, which is about 6 times smaller than its height. The cut-off diameter () can thus be rewritten as follows:
Figure 4
Calculated particle cut-off diameter () for the VTD as a function of airflow. Calculations are performed using Stokes' equations for a vertical cylinder with a diameter of 125 . The grey dot shows actual operating conditions, with measured airflows varying between 10 and 12 , leading to a cut-off diameter between 10 and 11 .
[Figure omitted. See PDF]
The value varies as a function of the pumped air flux when all the other parameters are fixed (Fig. ), so that it can easily be tuned to 10 . In an ambient air loaded with particles including a significant amount larger than 10 , perfect systems should exclude these largest fractions and therefore collect the same aerosol mass concentration with the same composition.
A tapered element oscillating microbalance (TEOM, Thermo Scientific), equipped with the same commercial PM10 head, was also installed beside the VTD and the PM10 systems (Fig. ). It measures the mass concentration of airborne particles directly, providing values considered as references for further comparison. A portable laser aerosol spectrometer (OPC, Model 1.108/1.109, Grimm), which measures particle size distribution over a large size range, was also installed ca. 3 away from these three systems. A 1.111 radial symmetric sampling head (Grimm) was installed at the air inlet of the instrument to ensure reasonable capture efficiency for large particles. The OPC measures the number of particles within 15 diameter intervals between 16 diameter channels of 0.30, 0.40, 0.50, 0.65, 0.80, 1.0, 1.6, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, and 25 . Counting by OPC is converted into mass, assuming the lognormal distribution of spherical particles. The volume of particles in the diameter interval is equal to , where is the geometric mean of and . With a particle density , commonly chosen to equal 2.2 , the mass, , is equal to the sum of all the channels under 10 : while the mass of coarse particles larger than 10 is obtained by summing the channels over 10 . This coarse particle mass fraction should not be sampled by our sampling devices.
2.2 Washing procedure for sampling instrumentsPrior to the field experiment, in the laboratory, 50 Petri dishes (PALL, filter storage box) were washed with detergent and rinsed with tap water, after which they were soaked in osmosed water containing 2 % of Decon90® for at least 15 h. They were then thoroughly rinsed with tap water followed by osmosed water before being soaked in acidified (HCl 1 %) osmosed water for 3 . Finally, the Petri dishes were rinsed with Milli-Q® water (18 ) and dried in an ISO-2 laminar flow hood. The filter holders and their PP boxes were cleaned using the same procedure. The PM10 head was disassembled, and each part was washed with tap water and detergent and then soaked in osmosed water containing Decon90® for several minutes. Finally, each part was washed with osmosed and Milli-Q water (18 ) and dried in the laminar flow hood. The tube of the VTD was washed with detergent and rinsed with Milli-Q water before being dried in the laminar flow hood.
2.3 Sample digestion
The filters coated with dust samples were brought back to the laboratory (ISO-7 clean room) and dissolved in sealed Teflon® (PTFE) digestion vessels by 3 of a mixture of sub-boiled () for 18 on a heater plate at 125 . All the Teflon vessels were previously cleaned with the detergent/acid procedure described above, completed with blank digestion. At the end of digestion, each vessel was opened, and the temperature of the heater plate was raised to 135 , until complete evaporation of all liquid. The temperature of the heater plate was then lowered to 80 , and 3 of a 30 % nitric acid solution was added to each vessel, which was then sealed. A period of 2 h later, the content of each vessel was transferred into a 60 polypropylene bottle (thoroughly detergent/acid cleaned), by adding Milli-Q water. Laboratory blanks (no filter), four field blanks (pristine filter), and two finely ground geostandards (SCO-1 and MAG-1 from USGS) were also prepared following the same digestion procedure.
2.4 Chemical analyses
An ARCOS (Spectro-Ametek) ICP-AES, equipped with a CETAC ultrasonic nebulizer, was used for elemental determination of Al, Ba, Ca, Cr, Fe, K, Li, Mg, Mn, Na, P, Sc, S, Sr, Ti, Zn, and Zr. A field-sector high-resolution inductively coupled plasma mass spectrometer (FS-HR-ICP-MS), Thermo Element 2, equipped with a concentric micro-nebulizer in a cyclonic nebulization chamber, was used for elemental determination of As, Be, Cd, Co, Cu, Mo, Ni, Pb, Rb, Se, Tl, U, V, and REEs. External linear calibration was performed for all elements analysed with ICP-AES, by measuring a set of multi-elementary solutions with concentrations up to 250 . The intercept was computed as the average of eight replicates of a blank sample (ultra-pure nitric acid diluted in Milli-Q water). High-resolution analysis avoids polyatomic interference for elements lighter than arsenic and also for REEs . The FS-HR-ICP-MS was externally calibrated for all elements analysed, with 14 replicates of a blank solution and 5 replicates of a 1 multi-elementary solution. The first analytical detection limit was obtained with analytical blanks and digestion with dilution water and acid reagents only, while the second field detection limit was obtained with blank filters transported to the field. For most of the elements, quantities found in blank filters were higher than analytical detection limits, so that blank correction used the average quantity found in blank filters. For a few elements (Pr, Eu, Tb, Dy, Ho, Tm, and Lu), blanks were below detection limits, so no blank correction was made. Seven elements (As, Cd, Cr, Mo, Ni, Sc, and Se) are not discussed because they cannot be handled by the statistical tools used here, as at least one measured value was below the field or analytical detection limit. Analytical results are provided in Appendix , Tables –.
2.5 Validation of analytical methods
There is no commercially available certified reference material comparable to the fine aerosols collected on filters. Two geostandards were therefore used as proxies: SCO-1 (typical of Upper Cretaceous silty marine shale) and MAG-1 (a fine-grained grey-brown clayey mud with low carbonate content, from the Wilkinson Basin of the Gulf of Maine). They were hand-crushed for 30 in an agate mortar to approximate aerosol grain size. The powders produced were deposited on a filter at the smallest amount that can be weighed (around 10 with an accuracy of 0.2 ) to obtain a mass as close as possible to field aerosol samples. A table with individual recovery rates, as well as individual measurement results for each certified element and aerosol sample, is proposed in Appendix , Table . Recovery rates for most elements ranged from 80 % to 120 % for SCO-1 and MAG-1 but could not be calculated for S, Se, and Tm because no value was available for comparison.
2.6 Computation of total aerosol mass concentration
The mass concentration was not directly measured because of the low expected weight and the nature of the cellulose-ester filters which are sensitive to moisture. That is why a TEOM was installed, as it directly provides aerosol mass concentration in air. In this region, almost all the particle mass can be assumed to be carried by silicate crustal particles, sea salts, sulfuric acid (), and additional calcium in the form of calcium carbonate (). A chemical reaction occurs between calcium carbonate and sulfuric acid, producing gypsum () and preventing the simultaneous presence of sulfuric acid and calcium carbonate . If carbonate predominates over sulfuric acid, the total particle mass concentration is computed as
If sulfuric acid predominates over carbonate, then where is estimated using aluminium and a crustal composition model, where aluminium accounts for 7.1 % of the mass . This value is consistent with that of 7.09 0.79 % observed by for Saharan dust. is estimated using sea salt sodium and a seawater composition model , where sodium accounts for 30.9 % of sea salt mass. Sea salt sodium is deduced by subtracting crustal sodium from total sodium, crustal sodium being deduced from aluminium , and a crustal composition model, where the ratio is equal to 0.0887 : where , , and are calculated using additional calcium and additional sulfur not included in crustal and sea salt estimation. and are defined respectively as calcium and sulfur of neither sea salt nor crustal origin. and are computed using the same crustal and sea salt composition models previously used:
Depending on the resulting products of calcium carbonate with sulfuric acid reaction, the mass associated with additional calcium and sulfur is computed as follows: where is the molar mass of the compound or element .
2.7 Multivariate analysis for compositional data (CoDA)
Compositional data are, by nature, difficult to handle straightforwardly. Any given component cannot vary independently from the others because the sum of all components is always equal to 100 %. If this closure constraint is not taken into account, spurious correlations and biased conclusions are to be expected . Appropriate mathematical tools must therefore be selected to overcome this drawback. These questions are extensively discussed in several papers . Briefly, the suitable sample space of any compositional vector , representing a -part subset of a whole , is the simplex , as defined by . This technique is particularly well adapted to situations where elemental ratios are more relevant than absolute concentrations.
Let and denote two compositional vectors in . Then , corresponding to the perturbation of by , in is given by with the closure-to-unity operation defined as
The neutral element of the perturbation is , and , while the perturbation vector expression compositional change from to , noted , is equal to , with . The centred log-ratio (clr) transformation is commonly performed to open the data before applying any multivariate techniques based on correlation: where denotes the geometric mean of the parts: . A principal component analysis (PCA) can then be computed on transformed data to summarize the structure of the data in a lower dimensional space (ideally two for the sake of simplicity of projection on a plane). A compositional biplot, where both samples and variables are plotted in the same space, can be used as a user-friendly graphical representation, but it differs from the original biplot by in the sense that rays formed by the variables are proportional to the standard deviation of their log ratios and that the length of a link between arrow heads of two rays represents the standard deviation of the log ratio between these compositional parts . Practically, the “acomp” (closure operation) and “princomp” (PCA projection) functions used here were provided by the “compositions” package for the R software , which was specifically designed to analyse compositional data . This data processing based on log-ratio computing is named “compositional data analysis” (CoDA).
Table 1
Sampling dates (local time) and aerosol mass concentrations directly measured by TEOM and calculated from chemical analysis of samples collected by the VTD and PM10, respectively. Masses derived from chemical analyses are computed using equations presented in Sect. . The last four columns (right) display mass proportion of sea salt and crustal aerosol for VTD and PM10 samples. Detailed results are shown in Tables and (Appendix ).
Sample | Date start | Date stop | TEOM | VTD | PM10 | VTD | VTD | PM10 | PM10 |
---|---|---|---|---|---|---|---|---|---|
name | sea salt % | crustal % | sea salt % | crustal % | |||||
YX03/04 | 29 March 2016 18:40 | 30 March 2016 09:12 | 21 | 19 | 17 | 14 % | 46 % | 24 % | 45 % |
YX05/06 | 30 March 2016 09:47 | 30 March 2016 18:26 | 18 | 27 | 22 | 25 % | 37 % | 25 % | 37 % |
YX07/08 | 30 March 2016 19:08 | 31 March 2016 09:03 | 33 | 33 | 28 | 16 % | 61 % | 13 % | 60 % |
YX09/10 | 31 March 2016 09:38 | 31 March 2016 18:29 | 86 | 63 | 66 | 8 % | 73 % | 10 % | 71 % |
YX11/12 | 31 March 2016 19:01 | 1 April 2016 09:09 | 41 | 40 | 34 | 23 % | 55 % | 25 % | 54 % |
YX13/14 | 1 April 2016 09:39 | 1 April 2016 18:19 | 175 | 140 | 145 | 14 % | 75 % | 15 % | 75 % |
YX15/16 | 1 April 2016 18:49 | 2 April 2016 09:38 | 111 | 124 | 116 | 4 % | 92 % | 4 % | 93 % |
YX17/18 | 2 April 2016 10:08 | 2 April 2016 19:23 | 679 | 769 | 711 | 1 % | 95 % | 1 % | 95 % |
YX19/20 | 2 April 2016 19:49 | 3 April 2016 09:52 | 82 | 99 | 84 | 18 % | 69 % | 15 % | 71 % |
YX21/22 | 3 April 2016 10:19 | 3 April 2016 18:29 | 66 | 75 | 70 | 29 % | 50 % | 31 % | 47 % |
YX23/24 | 3 April 2016 18:59 | 4 April 2016 10:01 | 42 | 41 | 35 | 55 % | 22 % | 59 % | 18 % |
YX25/26 | 4 April 2016 10:31 | 4 April 2016 19:31 | 97 | 103 | 94 | 17 % | 69 % | 19 % | 69 % |
YX27/28 | 4 April 2016 20:01 | 5 April 2016 10:00 | 36 | 35 | 29 | 33 % | 43 % | 34 % | 40 % |
YX29/30 | 5 April 2016 10:24 | 6 April 2016 09:06 | 157 | 133 | 120 | 6 % | 86 % | 6 % | 86 % |
YX31/32 | 6 April 2016 10:33 | 6 April 2016 18:51 | 85 | 108 | 91 | 24 % | 62 % | 23 % | 64 % |
YX33/34 | 6 April 2016 19:19 | 7 April 2016 07:16 | 35 | 45 | 40 | 40 % | 42 % | 39 % | 40 % |
3.1 Variability of sampling conditions
The sampling site can be influenced by local and remote soil dust emission, by sea salt, and by anthropogenic emissions. During the sampling campaign, a broad variety of meteorological conditions were observed, allowing different aerosol sources to be sampled. Average local wind speed varied from about 1 to 7 , with no preferred direction (Appendix , Fig. ). Backward air trajectories are presented for each sample pair in Appendix (Figs. –), indicating their differences in origin, leading to a variety of conditions for aerosol loading. Atmospheric aerosol loading presented a large range of values, from 21 to 679 (Table , TEOM values), with great variations between marine vs. crustal proportions in any given sample pair.
Figure 5
Daily average particle mass concentration size distribution in air on 31 March (a, aerosol concentration ca. 40 ), 6 April (b, aerosol concentration ca. 100 ), and 2 April, morning (c, aerosol concentration ca. 700 ). Measured using the Grimm OPC.
[Figure omitted. See PDF]
3.2 Size distribution of the sampled aerosolThe fraction of particles larger than 10 suspended in the air is shown by OPC measurements. For the entire field experiment, this coarse fraction represents, on average, 34 % of the total mass concentration of aerosols as plotted in Fig. , for three given periods with various dust concentrations. The presence of a significant amount of large particles in air makes the systems sensitive to possible inaccuracy and variations in their cut-off diameters: if the cut-off diameter were not the same for each sampling head in a given sample pair, the amount of large particles collected would not be the same and would produce differences in sampled aerosol mass concentration. Because chemical composition may be dependent on particle size, differences in cut-off diameters would also produce differences in chemical composition.
Figure 6
Comparisons of sample masses using a square-root scale. The lines are also shown. (a) Plot of chemically deduced mass of VTD and PM10 sampling heads vs. TEOM measurement. (b) Plot of chemically deduced mass of VTD vs. PM10 sampling heads.
[Figure omitted. See PDF]
3.3 Total aerosol mass concentration in airComparisons of the measured mass concentrations between the VTD, PM10, and the reference instrument TEOM are shown in Fig. and Table . Mass concentrations are averaged during each collection period. Plotted concentrations vary from 21 to 680 within a range that can be cleverly plotted using a square-root scale . Masses of particles collected by the VTD and PM10, deduced from calculations using Al, Na, S, and Ca, fit the TEOM values (Fig. a). Similar results are observed for each VTD and PM10 sample pair (Fig. b), suggesting the same collection efficiency for both sampling heads and hence the same cut-off diameter. The median value of the relative mass differences between the VTD and PM10 is 12 %, and values range from 3 % to 22 %. Such variability is of the same magnitude as that observed by or in and inter-comparison exercises or by in a comparison of entire monitoring networks. An orthogonal regression, also known as total least squares, was performed on the data presented here by treating the variances of and symmetrically. Orthogonal regressions were performed twice, with and without the highest point, which could potentially be considered an outlier. Regression slopes for the three possible combinations (PM10 vs. TEOM, VTD vs. TEOM, and VTD vs. PM10), with and without the highest point, are between 0.94 and 1.03. The value of 1 is always included in the 95 % confidence level interval associated with each slope, and intercepts are not significantly different from zero (see Tables and in Appendix ), suggesting that any potential bias is too small to be identified with our data. To summarize, the differences observed between aerosol masses measured by the three sampling systems are much lower than the daily variability observed during the field experiment. The coherence between direct measurement of masses (TEOM) and “chemical” weighing shows that substances not taken into account in our chemical budget (ammonium and organic molecules) do not significantly contribute to the total aerosol mass here.
3.4 Compositional data
The aim is now to compare chemical compositions of samples collected simultaneously by both the VTD and PM10, as differences may appear due to contamination or size segregation of particles. Note that major and trace elements are treated separately from the REEs in the following because of the particular importance of REEs as tracers of mineral particle origin .
Figure 7
Biplot for the two sampling devices (all elements except REEs). PM10 samples are figured with circles, and solid discs represent VTD samples. Lines between PM10 and VTD symbols link paired samples. Percentages of variability explained by the first two components are 61 % and 16 %, a total of 77 %.
[Figure omitted. See PDF]
Figure 8
Perturbation diagram as box plots for paired samples (all elements except REEs), measured by PM10 and the VTD. The horizontal blue line represents no perturbation.
[Figure omitted. See PDF]
3.4.1 Major and trace elementsThe first two axes of the compositional biplot built from major and trace elements, without REEs, explain 77 % of the total variance (61 % and 16 %, respectively), a high value, considering that 23 variables are taken into account for the analysis (Fig. ). The variability between each pair of samples (i.e. collections by PM10 and the VTD on the same day), figured by the segment linking the two samples of the same pair, appears to be much lower than the variability observed within the entire set of samples. In other words, each dust event can be characterized properly with respect to the others, independently of the sampling device used. This finding is in good agreement with a close examination of compositional changes between PM10 and the VTD for each pair of samples, expressed as perturbation vectors: , with (Fig. ). Interestingly, the neutral element , which indicates no perturbation, is included inside all the box plot quartiles. No systematic compositional shift, in terms of elemental ratios, can therefore be observed between the two sampling heads, at least for these elements, and it can be concluded that sample composition is not affected by the type of sampling head. Note, however, that Zn exhibits the greatest variability, suggesting noticeable random contamination. The slight differences observed between the two sampling heads in each paired sample are found to be correlated neither to air aerosol concentrations nor to wind speed. Potential contamination issues due to aluminium impaction plates were among the main reasons why sampling heads were tested in the field with natural aerosols. No systematic compositional differences were observed between the two sampling heads although they are made of different alloys. This observation strongly suggests that neither of the two devices (brand-new PM10 and VTD) would contaminate natural samples collected during this campaign.
Figure 9
REE biplot for the two sampling devices. PM10 samples are figured with circles, and solid discs represent VTD samples. Lines between circles and discs link paired samples. Percentages of variability explained by the first two components are 29 % and 22 %, a total of 51 %.
[Figure omitted. See PDF]
Figure 10
REE perturbation diagram as box plots for paired samples, measured by PM10 and the VTD. The horizontal blue line represents no perturbation.
[Figure omitted. See PDF]
3.4.2 Rare earth elements (REEs)In the compositional biplot built from REEs, only 51 % of the total variance is explained by the first two axes (Fig. ). This value is much lower than that obtained above for the other chemical elements (77 %) but with only half the number of variables. The corresponding perturbation vector diagram again shows no systematic difference between the two sampling heads (Fig. ). Because REEs essentially come from a stable crustal source, log ratios between these elements vary little within the sample set (almost 10 times less than the variability observed for the other elements). This stability explains why the percentage of variance expressed by the first two principal components is so low.
To test whether the differences observed between the two systems might be explained solely by analytical error, the behaviour of identical duplicate samples was simulated: 16 new pairs of compositions were generated, by pairing each VTD sample with a modified sample, where each REE measurement was randomly shifted inside the given uncertainty interval of that REE. These new pairs of simulated samples were then represented as a biplot (Fig. , Appendix ), producing results very similar to those observed for the real (VTD and PM10) paired samples. During this field campaign, the REE profiles were found to be stable and unaffected by the design of the sampling head.
4 Conclusions
The main advantage of this new inlet is its simple design associated with its low cost and the broad availability of the components, making this new inlet easy to build locally by everyone. A second possible reason to use the VTD is easier maintenance. Compositional data analysis tools have been used to present large sets of measurements at a glance, allowing us to perceive the compositional similarity of paired samples quickly and directly. No significant differences between the laboratory-made decanter sampling head and the commercial sampling head (based on impaction) were observed in terms of aerosol composition (including REEs) and total mass concentration, for samples collected in a source region of mineral dust, under very different meteorological conditions. In the source region investigated, where particle mass concentrations ranged from 20 to 700 according to TEOM values, the chemical composition of the aerosol fraction was therefore unaffected by the sampling head design. Consequently, both devices can be used for the determination of mass and chemical composition of aerosols in source regions or even simply to determine mass by gravimetry. An aerosol survey network can therefore be built using a combination of the two sampling devices without any measurable consequences for data reliability or consistency. This would also be the case for a time series if a PM10 was replaced by a VTD or vice versa.
Appendix A Air concentrations, measured values
Raw data of the paper are presented in Tables – for ICP-AES measurements, in Tables and for ICP-MS measurements, and in Tables and for REEs measured with ICP-MS. “DL” is “detection limit”, expressed in mass on the filter. “” is “less than concentration detection limit”; this concentration detection limit must be calculated by dividing the DL value (expressed in mass) by the air volume. Uncertainties are given for a 95 % confidence interval. The air volume uncertainty is constant at 1 % and not displayed.
Table A1
Elemental air concentrations measured with ICP-AES.
Element | Al | Ca | Fe | K | Mg | Na | |
---|---|---|---|---|---|---|---|
Wavelength (nm) | 396.2 | 396.847 | 238.2 | 766.491 | 279.553 | 589 | |
Analytical DL (ng) | 0.02 | 0.005 | 0.1 | 0.2 | 0.003 | 1 | |
Field DL (ng) | 0.5 | 13 | 0.8 | 3 | 1 | 79 | |
Sample name | Air volume () | ||||||
YX03 (VTD) | 10.52 | 0.63 0.02 | 1.7 0.1 | 0.4 0.01 | 0.86 0.04 | 0.32 0.01 | 0.9 0.3 |
YX04 (PM10) | 12.59 | 0.55 0.02 | 1.6 0.1 | 0.34 0.01 | 1.46 0.05 | 0.29 0.01 | 1.3 0.2 |
YX05 (VTD) | 5.89 | 0.71 0.02 | 2.6 0.1 | 0.44 0.02 | 2.05 0.08 | 0.33 0.02 | 2.2 0.5 |
YX06 (PM10) | 6.68 | 0.58 0.02 | 2.2 0.1 | 0.34 0.02 | 2.74 0.1 | 0.27 0.01 | 1.8 0.4 |
YX07 (VTD) | 10.02 | 1.43 0.04 | 2.5 0.1 | 0.87 0.03 | 1.77 0.06 | 0.65 0.02 | 1.7 0.3 |
YX08 (PM10) | 10.8 | 1.19 0.04 | 2.1 0.1 | 0.73 0.02 | 0.76 0.03 | 0.54 0.02 | 1.2 0.3 |
YX09 (VTD) | 6.04 | 3.2 0.1 | 3.7 0.2 | 1.78 0.06 | 1.58 0.07 | 1.41 0.05 | 1.8 0.5 |
YX10 (PM10) | 6.77 | 3.3 0.1 | 3.5 0.2 | 1.81 0.06 | 1.72 0.07 | 1.5 0.05 | 2.3 0.4 |
YX11 (VTD) | 9.59 | 1.54 0.05 | 2.4 0.1 | 0.94 0.03 | 0.8 0.04 | 0.98 0.03 | 2.9 0.3 |
YX12 (PM10) | 10.92 | 1.31 0.04 | 2.1 0.1 | 0.81 0.03 | 0.76 0.03 | 0.85 0.03 | 2.7 0.3 |
YX13 (VTD) | 5.71 | 7.5 0.2 | 4.2 0.2 | 4.1 0.1 | 9.32 0.3 | 3.3 0.1 | 6.9 0.6 |
YX14 (PM10) | 6.64 | 7.7 0.2 | 3.5 0.2 | 4.3 0.1 | 13.7 0.4 | 3.4 0.1 | 7.6 0.6 |
YX15 (VTD) | 10.85 | 8.1 0.2 | 2.2 0.1 | 4.4 0.1 | 2.27 0.08 | 2.08 0.07 | 2.3 0.3 |
YX16 (PM10) | 11.75 | 7.6 0.2 | 2 0.1 | 4.1 0.1 | 2.05 0.07 | 1.9 0.06 | 2.1 0.3 |
YX17 (VTD) | 6.53 | 52 2 | 3.4 0.2 | 29.6 0.9 | 13.8 0.4 | 14.1 0.4 | 6.7 0.6 |
YX18 (PM10) | 7.12 | 48 1 | 3.2 0.1 | 27.4 0.8 | 12.7 0.4 | 12.6 0.4 | 6.1 0.5 |
YX19 (VTD) | 10.33 | 4.9 0.1 | 3 0.1 | 2.61 0.08 | 2.5 0.09 | 1.78 0.06 | 5.8 0.4 |
YX20 (PM10) | 10.96 | 4.2 0.1 | 2.2 0.1 | 2.29 0.07 | 1.98 0.07 | 1.59 0.05 | 4.4 0.3 |
YX21 (VTD) | 5.48 | 2.63 0.08 | 3.7 0.2 | 1.48 0.05 | 1.03 0.06 | 1.58 0.05 | 6.9 0.6 |
YX22 (PM10) | 6.08 | 2.36 0.07 | 3.5 0.2 | 1.35 0.04 | 1.12 0.06 | 1.43 0.05 | 6.9 0.6 |
YX23 (VTD) | 10.76 | 0.64 0.02 | 1.9 0.1 | 0.39 0.02 | 1.41 0.05 | 1.14 0.04 | 7.1 0.4 |
YX24 (PM10) | 11.95 | 0.44 0.01 | 1.17 0.06 | 0.27 0.01 | 1.44 0.05 | 0.98 0.03 | 6.4 0.4 |
YX25 (VTD) | 6.79 | 5.1 0.2 | 3.4 0.2 | 2.97 0.09 | 1.93 0.07 | 2.41 0.08 | 5.9 0.5 |
YX26 (PM10) | 7.65 | 4.6 0.1 | 3.2 0.1 | 2.68 0.08 | 1.67 0.07 | 2.17 0.07 | 5.8 0.5 |
YX27 (VTD) | 10.73 | 1.06 0.03 | 1.98 0.09 | 0.66 0.02 | 0.53 0.03 | 0.85 0.03 | 3.6 0.3 |
YX28 (PM10) | 11.8 | 0.83 0.03 | 1.64 0.08 | 0.49 0.02 | 0.47 0.03 | 0.67 0.02 | 3.1 0.3 |
YX29 (VTD) | 16.66 | 8.1 0.2 | 1.37 0.06 | 4.87 0.15 | 4.6 0.1 | 3.88 0.12 | 3.4 0.2 |
YX30 (PM10) | 19.25 | 7.3 0.2 | 1.2 0.05 | 4.43 0.13 | 5.2 0.2 | 3.42 0.1 | 3 0.2 |
YX31 (VTD) | 5.92 | 4.8 0.1 | 4.2 0.2 | 2.61 0.08 | 3 0.1 | 2.64 0.09 | 8.5 0.7 |
YX32 (PM10) | 7.49 | 4.1 0.1 | 3.2 0.1 | 2.26 0.07 | 2.17 0.08 | 2.27 0.07 | 6.7 0.5 |
YX33 (VTD) | 8.31 | 1.37 0.04 | 2.2 0.1 | 0.82 0.03 | 0.69 0.04 | 1.16 0.04 | 5.7 0.5 |
YX34 (PM10) | 9.15 | 1.11 0.03 | 1.8 0.1 | 0.65 0.02 | 0.61 0.03 | 1.01 0.03 | 4.9 0.4 |
Elemental air concentrations measured with ICP-AES, continued.
Element | Ba | Li | Mn | P | S | Sc | Sr |
---|---|---|---|---|---|---|---|
Wavelength (nm) | 233.527 | 670.78 | 257.611 | 177.495 | 182.034 | 335.373 | 460.733 |
Analytical DL (ng) | 0.001 | 0.0002 | 0.001 | 0.01 | 0.9 | 0.001 | 0.002 |
Field DL (ng) | 0.02 | 0.002 | 0.1 | 0.2 | 85 | – | 0.05 |
Sample name | |||||||
YX03 | 6.2 0.3 | 0.53 0.03 | 7.3 0.4 | 56 2 | 1.6 0.3 | 0.2 0.1 | 10.8 0.5 |
YX04 | 5.4 0.2 | 0.47 0.02 | 6.5 0.4 | 49 2 | 0.9 0.2 | 9.4 0.4 | |
YX05 | 7.7 0.4 | 0.54 0.04 | 8.2 0.6 | 74 4 | 2.2 0.5 | 0.2 0.2 | 12.2 0.7 |
YX06 | 6.6 0.3 | 0.43 0.04 | 5.4 0.5 | 60 3 | 1.5 0.4 | 9.9 0.6 | |
YX07 | 12.7 0.4 | 1.19 0.05 | 16.2 0.7 | 39 2 | 1.2 0.3 | 0.2 0.1 | 20.7 0.8 |
YX08 | 10.6 0.4 | 0.96 0.04 | 14.1 0.6 | 34 2 | 1.3 0.3 | 0.2 0.1 | 17.2 0.7 |
YX09 | 22.2 0.8 | 2.65 0.09 | 31 1 | 62 3 | 2.2 0.5 | 0.9 0.2 | 45 2 |
YX10 | 23.0 0.8 | 3.0 0.1 | 31 1 | 62 3 | 2.7 0.5 | 0.6 0.2 | 47 2 |
YX11 | 16.3 0.6 | 1.28 0.05 | 18.7 0.8 | 41 2 | 1.9 0.3 | 0.4 0.1 | 24.7 0.9 |
YX12 | 13 0.4 | 1.17 0.04 | 16.03 0.7 | 36 2 | 1.5 0.3 | 0.3 0.1 | 21.5 0.8 |
YX13 | 48 2 | 6.9 0.2 | 71 3 | 129 5 | 3.8 0.6 | 1.5 0.3 | 86 3 |
YX14 | 51 2 | 7.2 0.2 | 72 3 | 132 5 | 4.3 0.5 | 1.5 0.2 | 90 3 |
YX15 | 47 1 | 6.4 0.2 | 65 2 | 99 4 | 1.4 0.3 | 1.4 0.1 | 38 1 |
YX16 | 45 1 | 6.1 0.2 | 62 2 | 92 3 | 1.2 0.3 | 1.3 0.1 | 34 1 |
YX17 | 348 11 | 62 2 | 446 14 | 684 21 | 11.4 0.7 | 10.2 0.4 | 318 10 |
YX18 | 319 10 | 58 2 | 411 13 | 627 19 | 10.6 0.7 | 9.2 0.3 | 295 9 |
YX19 | 30 1 | 4.6 0.1 | 38 1 | 83 3 | 3.7 0.4 | 0.8 0.2 | 39 1 |
YX20 | 25.6 0.8 | 4.2 0.1 | 34 1 | 81 3 | 3.4 0.3 | 0.9 0.1 | 34 1 |
YX21 | 17.8 0.7 | 2.4 0.09 | 24 1 | 55 3 | 4.1 0.6 | 0.5 0.3 | 27 1 |
YX22 | 15.9 0.6 | 2.08 0.08 | 21 1 | 50 3 | 3.8 0.5 | 0.3 0.2 | 25 1 |
YX23 | 4.2 0.2 | 0.64 0.03 | 6.9 0.4 | 17 2 | 2.8 0.3 | 0.2 0.2 | 11.9 0.5 |
YX24 | 3.1 0.2 | 0.53 0.03 | 4.8 0.3 | 21 1 | 2.7 0.3 | 9.1 0.4 | |
YX25 | 23.1 0.8 | 4.5 0.1 | 49 2 | 80 4 | 3.9 0.5 | 1.2 0.2 | 43 2 |
YX26 | 21.0 0.7 | 3.6 0.1 | 45 2 | 70 3 | 2.9 0.4 | 0.8 0.2 | 38 1 |
YX27 | 7.5 0.3 | 0.87 0.04 | 11.3 0.6 | 22 2 | 2.0 0.3 | 0.2 0.1 | 11.5 0.5 |
YX28 | 5.4 0.2 | 0.71 0.03 | 8.7 0.5 | 67 3 | 1.8 0.3 | 0.2 0.1 | 8.9 0.4 |
YX29 | 52 2 | 8.4 0.3 | 79 3 | 152 5 | 3.5 0.3 | 1.53 0.09 | 69 2 |
YX30 | 46 1 | 7.6 0.2 | 71 2 | 143 5 | 3.2 0.2 | 1.43 0.08 | 62 2 |
YX31 | 29 1 | 4.1 0.1 | 41 2 | 80 4 | 3.8 0.6 | 0.7 0.2 | 44 2 |
YX32 | 25.8 0.9 | 3.7 0.1 | 37 1 | 69 3 | 3.1 0.4 | 0.8 0.2 | 37 1 |
YX33 | 9.6 0.4 | 1.27 0.05 | 12.3 0.7 | 29 2 | 2.1 0.4 | 0.3 0.2 | 15.6 0.7 |
YX34 | 8.3 0.3 | 1.05 0.04 | 10.3 0.6 | 34 2 | 2.3 0.4 | 0.3 0.2 | 13.1 0.6 |
Elemental air concentrations measured with ICP-AES, continued.
Element | Ti | Zn | Zr |
---|---|---|---|
Wavelength (nm) | 334.187 | 213.86 | 339.2 |
Analytical DL (ng) | 0.01 | 0.001 | 0.003 |
Field DL (ng) | 0.2 | 0.1 | 0.01 |
Sample name | |||
YX03 | 29 2 | 9.1 0.4 | 1.3 0.3 |
YX04 | 26 1 | 11.3 0.5 | 1.1 0.2 |
YX05 | 28 2 | 11.9 0.6 | |
YX06 | 20 2 | 5.7 0.4 | |
YX07 | 76 3 | 16.7 0.6 | 3.1 0.3 |
YX08 | 64 2 | 61.7 2 | 2.6 0.3 |
YX09 | 177 6 | 11 0.6 | 7.1 0.5 |
YX10 | 189 6 | 9 0.5 | 8 0.5 |
YX11 | 85 3 | 25.3 0.9 | 4.1 0.3 |
YX12 | 71 3 | 25.5 0.9 | 3.3 0.3 |
YX13 | 430 14 | 29 1 | 17.3 0.7 |
YX14 | 438 14 | 17.7 0.7 | 17.5 0.7 |
YX15 | 452 14 | 19.4 0.7 | 17.8 0.6 |
YX16 | 431 13 | 12.1 0.5 | 16.7 0.6 |
YX17 | 3145 95 | 75 2 | 124 4 |
YX18 | 2871 87 | 71 2 | 111 3 |
YX19 | 275 9 | 14.4 0.6 | 10.8 0.5 |
YX20 | 228 7 | 15.1 0.6 | 9.5 0.4 |
YX21 | 157 6 | 10.4 0.6 | 5.5 0.5 |
YX22 | 129 5 | 5.3 0.4 | 5 0.5 |
YX23 | 32 2 | 7.5 0.4 | 1.5 0.3 |
YX24 | 19 1 | 6.8 0.3 | 1.1 0.2 |
YX25 | 336 11 | 18.4 0.8 | 15.9 0.6 |
YX26 | 266 9 | 9.5 0.5 | 12.2 0.5 |
YX27 | 68 3 | 8.3 0.4 | 2.9 0.3 |
YX28 | 46 2 | 7.4 0.3 | 2.1 0.2 |
YX29 | 488 15 | 37 1 | 21.1 0.7 |
YX30 | 440 13 | 34 1 | 19.1 0.6 |
YX31 | 265 9 | 27 1 | 11 0.6 |
YX32 | 236 8 | 25.2 0.9 | 9.5 0.5 |
YX33 | 73 3 | 9.5 0.5 | 3.2 0.4 |
YX34 | 58 2 | 10 0.5 | 2.1 0.3 |
Elemental air concentrations measured with ICP-MS.
Element | Be | Cd | Co | Cr | Cu | Mo | Ni |
---|---|---|---|---|---|---|---|
Isotope | 9 | 111 | 59 | 52 | 63 | 95 | 60 |
Analytical DL (ng) | 0.02 | 0.04 | 0.04 | 0.4 | 0.1 | 0.3 | 3 |
Field DL (ng) | 0.1 | 0.1 | 2 | 643 | 15 | 3 | 141 |
Sample name | |||||||
YX03 | 0.018 0.003 | 0.06 0.01 | 0.19 0.02 | 1.28 0.1 | |||
YX04 | 0.012 0.002 | 0.06 0.01 | 0.13 0.02 | 1.31 0.1 | |||
YX05 | 0.03 0.01 | 0.09 0.01 | 0.27 0.04 | 1.6 0.2 | |||
YX06 | 0.015 0.004 | 0.08 0.01 | 0.15 0.03 | 1.3 0.1 | |||
YX07 | 0.05 0.01 | 0.15 0.01 | 0.36 0.03 | 3.4 0.2 | |||
YX08 | 0.03 0.01 | 0.14 0.01 | 0.31 0.03 | 2.9 0.2 | 1 2 | ||
YX09 | 0.11 0.02 | 0.07 0.01 | 0.75 0.07 | 1.9 0.2 | |||
YX10 | 0.11 0.01 | 0.07 0.01 | 0.83 0.07 | 2.5 0.2 | 3 3 | ||
YX11 | 0.04 0.01 | 0.22 0.02 | 0.44 0.04 | 4.3 0.2 | 0.19 0.04 | 3 2 | |
YX12 | 0.04 0.01 | 0.2 0.02 | 0.35 0.03 | 3.1 0.2 | 0.15 0.04 | 2 2 | |
YX13 | 0.14 0.02 | 0.05 0.01 | 1.01 0.08 | 2 0.1 | 0.15 0.04 | 2 2 | |
YX14 | 0.28 0.04 | 0.08 0.01 | 2 0.2 | 10 3 | 4.1 0.3 | 0.35 0.07 | 6 4 |
YX15 | 0.25 0.03 | 0.04 0.005 | 1.7 0.1 | 3.1 0.2 | 0.19 0.04 | 3 2 | |
YX16 | 0.24 0.03 | 0.04 0.005 | 1.6 0.1 | 7 2 | 2.9 0.2 | 0.16 0.04 | 3 2 |
YX17 | 1.7 0.2 | 0.24 0.02 | 11.4 0.7 | 48 4 | 17.6 0.8 | 1.5 0.2 | 26 6 |
YX18 | 1.7 0.2 | 0.22 0.02 | 11.2 0.7 | 42 4 | 16.4 0.7 | 1.2 0.1 | 24 6 |
YX19 | 0.17 0.02 | 0.06 0.01 | 1.11 0.08 | 2.3 0.2 | 0.17 0.05 | 4 2 | |
YX20 | 0.14 0.02 | 0.05 0.01 | 1.06 0.08 | 6 2 | 2 0.1 | 0.18 0.04 | 4 2 |
YX21 | 0.08 0.01 | 0.09 0.01 | 0.61 0.06 | 1.5 0.2 | 4 4 | ||
YX22 | 0.07 0.01 | 0.09 0.01 | 1.2 0.1 | 1.4 0.1 | 0.35 0.07 | 5 4 | |
YX23 | 0.026 0.004 | 0.04 0.01 | 0.2 0.02 | 1.1 0.1 | 4 2 | ||
YX24 | 0.014 0.003 | 0.04 0.005 | 0.15 0.02 | 1.1 0.1 | 0.12 0.03 | 3 2 | |
YX25 | 0.15 0.02 | 0.07 0.01 | 1.1 0.09 | 2.5 0.2 | 0.24 0.06 | 2 3 | |
YX26 | 0.16 0.02 | 0.06 0.01 | 0.99 0.08 | 2.2 0.2 | 0.22 0.05 | 4 3 | |
YX27 | 0.03 0.01 | 0.05 0.01 | 0.28 0.03 | 1.4 0.1 | 0.16 0.04 | 2 2 | |
YX28 | 0.028 0.004 | 0.05 0.01 | 0.22 0.02 | 1.1 0.1 | 2 2 | ||
YX29 | 0.33 0.04 | 0.13 0.01 | 2 0.1 | 10 1 | 4.5 0.2 | 0.35 0.04 | 6 2 |
YX30 | 0.29 0.04 | 0.12 0.01 | 1.8 0.1 | 9 1 | 4.8 0.2 | 0.33 0.04 | 6 2 |
YX31 | 0.17 0.03 | 0.14 0.02 | 1.1 0.1 | 6.7 0.4 | 4 4 | ||
YX32 | 0.14 0.02 | 0.12 0.01 | 1.04 0.07 | 2.7 0.2 | 3 3 | ||
YX33 | 0.04 0.01 | 0.06 0.01 | 0.36 0.04 | 1.8 0.1 | 2 2 | ||
YX34 | 0.03 0.01 | 0.06 0.01 | 0.36 0.04 | 1.6 0.1 | 2 2 |
Elemental air concentrations measured with ICP-MS, continued.
Element | Pb | Rb | Sb | Se | Tl | U | V |
---|---|---|---|---|---|---|---|
Isotope | 208 | 85 | 121 | 77 | 205 | 238 | 51 |
Analytical DL (ng) | 0.01 | 0.1 | 0.02 | 0.5 | 0.002 | 0.01 | 0.4 |
Field DL (ng) | 2 | 4 | 0.6 | — | 0.1 | 0.04 | 2 |
Sample name | |||||||
YX03 | 4 1.1 | 1.04 0.05 | 0.6 0.04 | 0.4 0.1 | 0.017 0.003 | 0.04 0.01 | 2.8 0.1 |
YX04 | 3.3 0.9 | 0.98 0.05 | 0.55 0.04 | 0.29 0.09 | 0.014 0.003 | 0.03 0.01 | 2.9 0.1 |
YX05 | 3.4 0.9 | 1.11 0.07 | 0.51 0.04 | 0.18 0.09 | 0.011 0.003 | 0.03 0.01 | 2.2 0.1 |
YX06 | 3.3 0.9 | 1.05 0.06 | 0.49 0.04 | 0.17 0.08 | 0.012 0.003 | 0.04 0.01 | 2.1 0.1 |
YX07 | 4.9 1.3 | 2 0.09 | 1.2 0.08 | 0.14 0.06 | 0.023 0.004 | 0.07 0.01 | 3.3 0.2 |
YX08 | 4.4 1.2 | 1.63 0.07 | 1.12 0.07 | 0.14 0.06 | 0.02 0.004 | 0.05 0.01 | 2.7 0.1 |
YX09 | 3.4 1 | 4.0 0.2 | 0.43 0.03 | 0.03 0.01 | 0.14 0.03 | 5.6 0.3 | |
YX10 | 3.5 0.9 | 4.3 0.2 | 0.38 0.03 | 0.09 0.07 | 0.03 0.01 | 0.14 0.03 | 5.9 0.3 |
YX11 | 5.9 1.5 | 2.3 0.1 | 1.11 0.07 | 0.3 0.09 | 0.027 0.005 | 0.08 0.02 | 3.6 0.2 |
YX12 | 5.2 1.4 | 2.01 0.09 | 1.03 0.07 | 0.22 0.07 | 0.024 0.004 | 0.07 0.01 | 3.1 0.1 |
YX13 | 2 0.6 | 5.6 0.2 | 0.28 0.02 | 0.12 0.06 | 0.03 0.01 | 0.13 0.03 | 6.4 0.3 |
YX14 | 4 1.1 | 11.7 0.5 | 0.53 0.04 | 0.3 0.1 | 0.07 0.01 | 0.28 0.06 | 13.6 0.6 |
YX15 | 3.1 0.8 | 8.7 0.3 | 0.4 0.03 | 0.18 0.06 | 0.05 0.01 | 0.28 0.06 | 11.2 0.5 |
YX16 | 2.6 0.7 | 8 0.3 | 0.36 0.03 | 0.15 0.06 | 0.05 0.01 | 0.24 0.05 | 10.3 0.5 |
YX17 | 15.3 4 | 63 2 | 0.45 0.03 | 0.4 0.1 | 0.33 0.05 | 1.9 0.4 | 80 4 |
YX18 | 13 3 | 60 2 | 0.4 0.03 | 0.4 0.1 | 0.31 0.05 | 1.6 0.3 | 77 3 |
YX19 | 3.2 0.9 | 5.7 0.2 | 0.22 0.02 | 0.5 0.2 | 0.05 0.01 | 0.16 0.04 | 11.9 0.5 |
YX20 | 2.6 0.7 | 4.9 0.2 | 0.21 0.02 | 0.6 0.2 | 0.05 0.01 | 0.14 0.03 | 10.7 0.5 |
YX21 | 2.3 0.7 | 3.3 0.1 | 0.9 0.2 | 0.03 0.01 | 0.11 0.02 | 11.2 0.5 | |
YX22 | 2 0.6 | 3 0.1 | 0.5 0.1 | 0.03 0.01 | 0.1 0.02 | 9.9 0.5 | |
YX23 | 1.5 0.4 | 1.02 0.05 | 0.23 0.02 | 0.6 0.2 | 0.01 0.002 | 0.02 0.01 | 9.7 0.4 |
YX24 | 1.5 0.4 | 0.83 0.05 | 0.21 0.02 | 0.8 0.2 | 0.011 0.002 | 0.017 0.005 | 9.2 0.5 |
YX25 | 4.2 1.1 | 5.9 0.2 | 0.72 0.2 | 0.05 0.01 | 0.18 0.04 | 11.8 0.5 | |
YX26 | 3.7 1 | 5.6 0.2 | 0.5 0.2 | 0.05 0.01 | 0.14 0.03 | 11.6 0.5 | |
YX27 | 2.7 0.7 | 1.37 0.06 | 0.34 0.02 | 0.5 0.1 | 0.017 0.003 | 0.05 0.01 | 7.4 0.3 |
YX28 | 2.6 0.7 | 1.09 0.05 | 0.33 0.02 | 0.7 0.2 | 0.017 0.003 | 0.03 0.01 | 6.7 0.3 |
YX29 | 6 1 | 10.7 0.4 | 0.56 0.04 | 0.6 0.2 | 0.07 0.01 | 0.25 0.06 | 18.1 0.8 |
YX30 | 6 1 | 10.4 0.4 | 0.54 0.03 | 0.5 0.1 | 0.06 0.01 | 0.24 0.05 | 16.8 0.8 |
YX31 | 5 2 | 5.8 0.3 | 0.6 0.2 | 0.04 0.01 | 0.15 0.04 | 10.6 0.6 | |
YX32 | 5 1 | 5.4 0.2 | 0.33 0.02 | 0.5 0.1 | 0.04 0.01 | 0.14 0.03 | 9.3 0.4 |
YX33 | 3.3 0.9 | 1.80 0.08 | 0.8 0.2 | 0.024 0.004 | 0.05 0.01 | 6.2 0.3 | |
YX34 | 2.8 0.8 | 1.46 0.07 | 0.26 0.02 | 0.8 0.2 | 0.017 0.003 | 0.04 0.01 | 5.3 0.3 |
REE air concentrations measured with ICP-MS.
Element | La | Ce | Pr | Nd | Sm | Eu | Gd |
---|---|---|---|---|---|---|---|
Isotope | 139 | 140 | 141 | 146 | 147 | 153 | 157 |
Analytical DL (ng) | 0.01 | 0.004 | 0.001 | 0.01 | 0.01 | 0.01 | 0.004 |
Field DL (ng) | 0.4 | 0.5 | 0.1 | 0.2 | 0.05 | 0.03 | 0.1 |
Sample name | |||||||
YX03 | 0.37 0.07 | 0.8 0.2 | 0.09 0.02 | 0.3 0.1 | 0.07 0.02 | 0.013 0.004 | 0.05 0.01 |
YX04 | 0.32 0.06 | 0.6 0.1 | 0.07 0.01 | 0.3 0.1 | 0.06 0.02 | 0.011 0.003 | 0.05 0.01 |
YX05 | 0.41 0.08 | 0.8 0.2 | 0.1 0.02 | 0.4 0.1 | 0.09 0.02 | 0.016 0.005 | 0.04 0.01 |
YX06 | 0.36 0.07 | 0.7 0.2 | 0.08 0.02 | 0.3 0.1 | 0.07 0.02 | 0.012 0.004 | 0.04 0.01 |
YX07 | 0.9 0.2 | 1.7 0.4 | 0.19 0.03 | 0.8 0.3 | 0.13 0.03 | 0.028 0.009 | 0.11 0.03 |
YX08 | 0.7 0.1 | 1.4 0.3 | 0.16 0.03 | 0.6 0.2 | 0.12 0.03 | 0.024 0.007 | 0.1 0.03 |
YX09 | 2.0 0.3 | 3.8 0.8 | 0.45 0.08 | 1.9 0.7 | 0.33 0.08 | 0.08 0.02 | 0.27 0.07 |
YX10 | 2.0 0.3 | 4.0 0.9 | 0.47 0.08 | 1.8 0.7 | 0.36 0.09 | 0.07 0.02 | 0.28 0.07 |
YX11 | 0.9 0.2 | 2 0.4 | 0.22 0.04 | 0.9 0.3 | 0.18 0.04 | 0.04 0.01 | 0.13 0.03 |
YX12 | 0.8 0.1 | 1.6 0.3 | 0.19 0.03 | 0.7 0.3 | 0.15 0.04 | 0.031 0.009 | 0.11 0.03 |
YX13 | 2.2 0.4 | 4.4 0.9 | 0.53 0.09 | 1.9 0.7 | 0.4 0.1 | 0.07 0.02 | 0.29 0.07 |
YX14 | 4 0.7 | 7 2 | 0.9 0.2 | 4 1 | 0.7 0.2 | 0.15 0.05 | 0.6 0.1 |
YX15 | 4.7 0.8 | 10 2 | 1.1 0.2 | 4 2 | 0.8 0.2 | 0.16 0.05 | 0.6 0.1 |
YX16 | 4.2 0.7 | 9 2 | 0.9 0.2 | 4 1 | 0.7 0.2 | 0.14 0.04 | 0.6 0.1 |
YX17 | 31 5 | 60 10 | 7 1 | 24 9 | 5 1 | 1 0.3 | 4.1 1 |
YX18 | 28 5 | 60 10 | 7 1 | 25 9 | 5 1 | 0.9 0.3 | 3.7 0.9 |
YX19 | 2.6 0.4 | 5 1 | 0.6 0.1 | 2 0.7 | 0.4 0.1 | 0.08 0.02 | 0.33 0.08 |
YX20 | 2.5 0.4 | 5 1 | 0.56 0.09 | 2.2 0.8 | 0.4 0.1 | 0.08 0.02 | 0.33 0.08 |
YX21 | 1.5 0.3 | 3.1 0.7 | 0.33 0.06 | 1.4 0.5 | 0.28 0.07 | 0.05 0.02 | 0.19 0.05 |
YX22 | 1.5 0.3 | 3 0.6 | 0.34 0.06 | 1.4 0.5 | 0.26 0.06 | 0.06 0.02 | 0.19 0.05 |
YX23 | 0.36 0.07 | 0.7 0.2 | 0.08 0.01 | 0.3 0.1 | 0.05 0.01 | 0.013 0.004 | 0.06 0.02 |
YX24 | 0.27 0.05 | 0.5 0.1 | 0.06 0.01 | 0.23 0.09 | 0.04 0.01 | 0.008 0.003 | 0.034 0.009 |
YX25 | 3.2 0.5 | 6 1 | 0.7 0.1 | 3 1 | 0.6 0.1 | 0.14 0.04 | 0.5 0.1 |
YX26 | 2.7 0.5 | 6 1 | 0.6 0.1 | 2.5 1 | 0.5 0.1 | 0.1 0.03 | 0.4 0.1 |
YX27 | 0.7 0.1 | 1.3 0.3 | 0.15 0.03 | 0.6 0.2 | 0.12 0.03 | 0.026 0.008 | 0.08 0.02 |
YX28 | 0.52 0.09 | 1 0.2 | 0.12 0.02 | 0.5 0.2 | 0.09 0.02 | 0.02 0.006 | 0.07 0.02 |
YX29 | 4.6 0.8 | 9 2 | 1.1 0.2 | 4 1 | 0.8 0.2 | 0.15 0.04 | 0.6 0.2 |
YX30 | 4.3 0.7 | 9 2 | 1.0 0.2 | 4 1 | 0.8 0.2 | 0.15 0.04 | 0.6 0.1 |
YX31 | 2.7 0.5 | 5 1 | 0.6 0.1 | 2.1 0.8 | 0.5 0.1 | 0.09 0.03 | 0.34 0.09 |
YX32 | 2.2 0.4 | 4.5 1 | 0.51 0.09 | 1.9 0.7 | 0.37 0.09 | 0.08 0.02 | 0.26 0.07 |
YX33 | 0.8 0.1 | 1.7 0.4 | 0.19 0.03 | 0.8 0.3 | 0.14 0.04 | 0.028 0.009 | 0.12 0.03 |
YX34 | 0.7 0.1 | 1.3 0.3 | 0.14 0.02 | 0.6 0.2 | 0.1 0.03 | 0.021 0.006 | 0.08 0.02 |
REE air concentrations measured with ICP-MS, continued.
Element | Tb | Dy | Ho | Er | Tm | Yb | Lu |
---|---|---|---|---|---|---|---|
Isotope | 159 | 163 | 165 | 166 | 169 | 172 | 175 |
Analytical DL (ng) | 0.003 | 0.004 | 0.001 | 0.001 | 0.01 | 0.002 | 0.001 |
Field DL (ng) | 0.02 | 0.05 | 0.01 | 0.02 | — | 0.04 | 0.01 |
Sample name | |||||||
YX03 | 0.007 0.002 | 0.05 0.01 | 0.009 0.002 | 0.027 0.007 | 0.004 0.002 | 0.019 0.005 | 0.003 0.0008 |
YX04 | 0.007 0.002 | 0.04 0.01 | 0.008 0.002 | 0.019 0.005 | 0.003 0.002 | 0.018 0.004 | 0.0019 0.0005 |
YX05 | 0.007 0.002 | 0.05 0.02 | 0.008 0.002 | 0.026 0.007 | 0.006 0.003 | 0.025 0.006 | 0.004 0.001 |
YX06 | 0.007 0.002 | 0.04 0.01 | 0.007 0.002 | 0.024 0.007 | 0.005 0.003 | 0.023 0.006 | 0.005 0.001 |
YX07 | 0.019 0.004 | 0.11 0.03 | 0.019 0.004 | 0.05 0.01 | 0.007 0.002 | 0.05 0.01 | 0.007 0.002 |
YX08 | 0.013 0.003 | 0.08 0.02 | 0.016 0.003 | 0.05 0.01 | 0.007 0.002 | 0.034 0.008 | 0.006 0.001 |
YX09 | 0.06 0.01 | 0.23 0.07 | 0.042 0.009 | 0.12 0.03 | 0.019 0.005 | 0.10 0.02 | 0.014 0.003 |
YX10 | 0.042 0.009 | 0.24 0.07 | 0.045 0.009 | 0.13 0.04 | 0.02 0.006 | 0.12 0.03 | 0.017 0.004 |
YX11 | 0.02 0.004 | 0.14 0.04 | 0.023 0.005 | 0.06 0.02 | 0.01 0.003 | 0.05 0.01 | 0.008 0.002 |
YX12 | 0.015 0.003 | 0.1 0.03 | 0.018 0.004 | 0.06 0.02 | 0.006 0.002 | 0.05 0.01 | 0.007 0.002 |
YX13 | 0.045 0.009 | 0.24 0.07 | 0.049 0.01 | 0.13 0.04 | 0.018 0.005 | 0.13 0.03 | 0.017 0.004 |
YX14 | 0.08 0.02 | 0.5 0.1 | 0.09 0.02 | 0.26 0.07 | 0.032 0.009 | 0.2 0.05 | 0.028 0.007 |
YX15 | 0.09 0.02 | 0.5 0.2 | 0.09 0.02 | 0.28 0.07 | 0.038 0.01 | 0.25 0.06 | 0.034 0.008 |
YX16 | 0.07 0.01 | 0.5 0.1 | 0.09 0.02 | 0.25 0.07 | 0.034 0.009 | 0.19 0.04 | 0.029 0.007 |
YX17 | 0.6 0.1 | 3 1 | 0.7 0.1 | 1.7 0.5 | 0.27 0.07 | 1.5 0.3 | 0.23 0.05 |
YX18 | 0.5 0.1 | 3 1 | 0.6 0.1 | 1.7 0.5 | 0.22 0.06 | 1.5 0.3 | 0.22 0.05 |
YX19 | 0.05 0.01 | 0.3 0.09 | 0.05 0.01 | 0.15 0.04 | 0.022 0.006 | 0.13 0.03 | 0.019 0.005 |
YX20 | 0.045 0.009 | 0.29 0.09 | 0.05 0.01 | 0.14 0.04 | 0.018 0.005 | 0.13 0.03 | 0.019 0.004 |
YX21 | 0.029 0.006 | 0.18 0.06 | 0.033 0.007 | 0.1 0.03 | 0.012 0.004 | 0.09 0.02 | 0.011 0.003 |
YX22 | 0.032 0.007 | 0.18 0.06 | 0.034 0.007 | 0.09 0.02 | 0.013 0.004 | 0.08 0.02 | 0.013 0.003 |
YX23 | 0.004 0.001 | 0.05 0.01 | 0.009 0.002 | 0.024 0.007 | 0.004 0.002 | 0.021 0.005 | 0.0022 0.0006 |
YX24 | 0.005 0.001 | 0.03 0.01 | 0.006 0.001 | 0.011 0.003 | 0.002 0.001 | 0.017 0.004 | 0.0024 0.0007 |
YX25 | 0.06 0.01 | 0.4 0.1 | 0.08 0.01 | 0.21 0.06 | 0.03 0.008 | 0.19 0.04 | 0.028 0.007 |
YX26 | 0.06 0.01 | 0.32 0.1 | 0.06 0.01 | 0.17 0.04 | 0.026 0.007 | 0.15 0.03 | 0.022 0.005 |
YX27 | 0.012 0.003 | 0.09 0.03 | 0.015 0.003 | 0.05 0.01 | 0.006 0.002 | 0.03 0.007 | 0.005 0.001 |
YX28 | 0.009 0.002 | 0.06 0.02 | 0.012 0.002 | 0.035 0.01 | 0.005 0.002 | 0.028 0.007 | 0.004 0.001 |
YX29 | 0.09 0.02 | 0.5 0.2 | 0.1 0.02 | 0.26 0.07 | 0.035 0.009 | 0.24 0.05 | 0.033 0.008 |
YX30 | 0.08 0.02 | 0.5 0.2 | 0.09 0.02 | 0.27 0.07 | 0.035 0.009 | 0.22 0.05 | 0.032 0.008 |
YX31 | 0.05 0.01 | 0.3 0.1 | 0.05 0.01 | 0.17 0.04 | 0.022 0.006 | 0.14 0.03 | 0.022 0.005 |
YX32 | 0.039 0.008 | 0.28 0.09 | 0.048 0.01 | 0.12 0.03 | 0.019 0.005 | 0.11 0.02 | 0.014 0.003 |
YX33 | 0.014 0.003 | 0.08 0.03 | 0.018 0.004 | 0.05 0.01 | 0.007 0.003 | 0.05 0.01 | 0.007 0.002 |
YX34 | 0.013 0.003 | 0.07 0.02 | 0.015 0.003 | 0.04 0.01 | 0.006 0.002 | 0.035 0.008 | 0.006 0.001 |
Recoveries of geostandards MAG-1 in Table and SCO-1 in Table .
Table B1
MAG-1 recovery rates. Elements have a recovery rate between 68 % and 130 %, except for Zn and Ni. The very low amount of geostandard used ( 10 ) could explain the difference observed in recovery rates because subsampling heterogeneity is possible with such small amounts. Zn and Ni are overestimated, probably due to contamination.
Analysed by | Measured | Recovery rate | Analysed by | Measured | Recovery rate |
---|---|---|---|---|---|
ICP-AES | ICP-MS | ||||
Al | 80 000 | 92 % | Be | 2.99 | 93 % |
Ba | 433 | 90 % | Rb | 160 | 107 % |
Ca | 9300 | 95 % | Mo | 1.22 | 76 % |
Fe | 49 000 | 102 % | Cd | 0.265 | 130 % |
K | 34 000 | 110 % | Sb | 0.873 | 91 % |
Li | 100 | 130 % | Pb | 25.1 | 105 % |
Mg | 19 000 | 106 % | U | 2.69 | 100 % |
Mn | 784 | 130 % | V | 159 | 110 % |
Na | 19 000 | 68 % | Cr | 103 | 107 % |
P | 826 | 120 % | Co | 23 | 120 % |
Sc | 16.7 | 98 % | Ni | 80.3 | 150 % |
Sr | 122 | 82 % | Cu | 29 | 97 % |
Ti | 3.82 000 | 85 % | As | 8.31 | 90 % |
Zn | 187 | 140 % | La | 44 | 110 % |
Zr | 144 | 110 % | Ce | 91 | 109 % |
Pr | 10.7 | 120 % | |||
Nd | 41 | 115 % | |||
Sm | 7.7 | 109 % | |||
Eu | 1.49 | 98 % | |||
Gd | 6.2 | 104 % | |||
Tb | 0.87 | 90 % | |||
Dy | 4.8 | 90 % | |||
Ho | 0.88 | 82 % | |||
Er | 2.5 | 103 % | |||
Tm | 0.34 | 76 % | |||
Yb | 2.3 | 82 % | |||
Lu | 0.33 | 76 % |
SCO-1 recovery rates. Elements, except Na (recovery rate 150 %), have a recovery rate between 70 % and 130 %. The very low amount of geostandard used ( 10 ) could explain the difference observed in recovery rates because subsampling heterogeneity is possible with such small amounts.
Analysed by | Measured | Recovery rate | Analysed by | Measured | Recovery rate |
---|---|---|---|---|---|
ICP-AES | ICP-MS | ||||
Al | 58 500 | 81 % | Be | 1.87 | 104 % |
Ba | 426 | 75 % | Rb | 135 | 120 % |
Ca | 13 100 | 70 % | Mo | 1.46 | 104 % |
Fe | 30 300 | 84 % | Sb | 2.73 | 109 % |
K | 22 100 | 96 % | Pb | 32.6 | 105 % |
Li | 50 | 110 % | V | 160 | 120 % |
Mg | 13 100 | 80 % | Cr | 76.3 | 110 % |
Mn | 340 | 83 % | Co | 12.7 | 120 % |
Na | 10 100 | 150 % | Ni | 28.6 | 106 % |
P | 827 | 90 % | Cu | 31.6 | 109 % |
Sc | 10.06 | 92 % | As | 12.2 | 101 % |
Sr | 127 | 75 % | La | 32 | 104 % |
Ti | 2.84 | 75 % | Ce | 63 | 98 % |
Zn | 117 | 120 % | Pr | 7.7 | 110 % |
Zr | 129 | 81 % | Nd | 29 | 110 % |
Sm | 5.6 | 102 % | |||
Eu | 1.20 | 113 % | |||
Gd | 4.6 | 101 % | |||
Tb | 0.66 | 87 % | |||
Dy | 3.8 | 96 % | |||
Ho | 0.72 | 76 % | |||
Er | 2.1 | 82 % | |||
Tm | 0.31 | 72 % | |||
Yb | 2.0 | 84 % | |||
Lu | 0.31 | 79 % |
Wind speed and direction are measured continuously at the sampling location, and backward air trajectories are calculated using the online facility on NOAA HYSPLIT model web pages . Trajectories for a 24 h period are calculated every 6 h (at 00:00, 06:00, 12:00, and 18:00).
Figure C1
Vector representing local wind conditions at the sampling station. The length of the vector represents wind speed average, and its angle indicates the average direction during each sampling period.
[Figure omitted. See PDF]
Figure C2
Backward trajectories of sample pairs YX03–YX04, YX05–YX06, YX07–YX08, and YX09–YX10. The axis is longitude, and the axis is latitude. Two or three trajectories are associated with a given sample pair of 12 duration.
[Figure omitted. See PDF]
Figure C3
Backward trajectories of sample pairs YX11–YX12, YX13–YX14, YX15–YX16, and YX17–YX18. The axis is longitude, and the axis is latitude. Two or three trajectories are associated with a given sample pair of 12 duration.
[Figure omitted. See PDF]
Figure C4
Backward trajectories of sample pairs YX19–YX20, YX21–YX22, YX23–YX24, and YX25–YX26. The axis is longitude, and the axis is latitude. Two or three trajectories are associated with a given sample pair of 12 duration.
[Figure omitted. See PDF]
Figure C5
Backward trajectories of sample pairs YX27–YX28, YX29–YX30, YX31–YX32, and YX33–YX34. The axis is longitude, and the axis is latitude. Two or three trajectories are associated with a given sample pair of 12 duration, except for the pair YX29–YX30, for which four trajectories are necessary because the sampling duration was 24 h.
[Figure omitted. See PDF]
Appendix D Mass comparison statistical parametersTable D1
Optimal slope and intercept using orthogonal regressions, including the heavy loaded sample.
Slope | Intercept | |
---|---|---|
() | ||
[95 % confidence interval] | ||
VTD (TEOM) | 0.97 [0.78, 1.16] | 3 [18, +15] |
PM10 (TEOM) | 0.93 [0.79, 1.07] | 9 [17, +8] |
VTD (PM10) | 1.03 [0.96, 1.10] | 4 [1, +9] |
Optimal slope and intercept using orthogonal regressions, excluding the heavy loaded sample.
Slope | Intercept | |
---|---|---|
() | ||
[95 % confidence interval] | ||
VTD (TEOM) | 0.98 [0.76, 1.20] | 5.5 [8, +19] |
PM10 (TEOM) | 0.94 [0.77, 1.11] | 0.5 [9, +10] |
VTD (PM10) | 1.03 [0.94, 1.12] | 5.4 [0.2, +11] |
Table E1
VTD aerosol mass concentrations derived from chemical analyses with associated analytical uncertainties (95 % confidence interval).
Sample | [Total | [Sea | [Crustal] | [Calcium |
---|---|---|---|---|
name | VTD] | salt] | species] | |
YX03 | 19 1 | 3 1 | 9 0.3 | 8 0.4 |
YX05 | 27 2 | 7 2 | 10 0.3 | 10 1 |
YX07 | 33 2 | 5 1 | 20 1 | 8 2 |
YX09 | 63 4 | 5 1 | 45 1 | 12 3 |
YX11 | 40 1 | 9 1 | 22 1 | 9 1 |
YX13 | 140 4 | 20 2 | 106 3 | 15 1 |
YX15 | 124 4 | 5 1 | 115 3 | 5 1 |
YX17 | 769 22 | 7 2 | 729 22 | 33 2 |
YX19 | 99 3 | 18 1 | 68 2 | 13 1 |
YX21 | 75 3 | 22 2 | 37 1 | 16 1 |
YX23 | 41 2 | 23 1 | 9 0.3 | 10 0.4 |
YX25 | 103 3 | 18 2 | 71 2 | 14 1 |
YX27 | 35 1 | 11 1 | 15 0.5 | 8 0.5 |
YX29 | 133 4 | 9 1 | 115 3 | 10 0.4 |
YX31 | 108 3 | 26 2 | 67 2 | 15 1 |
YX33 | 45 2 | 18 1 | 19 1 | 8 1 |
aerosol mass concentrations derived from chemical analyses with associated analytical uncertainties (95 % confidence interval).
Sample | [Total | [Sea | [Crustal] | [Calcium |
---|---|---|---|---|
name | VTD] | salt] | species] | |
YX04 | 17 2 | 4 1 | 8 0.2 | 5 1.6 |
YX06 | 22 3 | 6 1 | 8 0.3 | 8 3 |
YX08 | 28 2 | 4 1 | 17 1 | 7 2 |
YX10 | 66 2 | 6 1 | 46 1 | 13 1 |
YX12 | 34 2 | 8 1 | 18 1 | 7 2 |
YX14 | 145 4 | 22 2 | 108 3 | 14 1 |
YX16 | 116 3 | 5 1 | 107 3 | 4 0 |
YX18 | 711 20 | 6 2 | 674 20 | 31 2 |
YX20 | 84 2 | 13 1 | 60 2 | 12 1 |
YX22 | 70 2 | 22 2 | 33 1 | 15 1 |
YX24 | 35 1 | 21 1 | 6 0.2 | 8 0.3 |
YX26 | 94 3 | 17 2 | 65 2 | 11 1 |
YX28 | 29 1 | 10 1 | 12 0.4 | 7 0.4 |
YX30 | 120 3 | 8 1 | 104 3 | 9 0.3 |
YX32 | 91 3 | 21 2 | 58 2 | 12 1 |
YX34 | 40 1 | 16 1 | 16 0.5 | 8 0.5 |
Figure F1
REE biplot for two VTD simulation results. Percentages of variability explained by the first two components are 27 % and 19 %, a total of 46 %.
[Figure omitted. See PDF]
Data availability
No other data than those presented here in tables were used in this article.
Author contributions
All the authors contributed to this paper to an extent, reflected by their rank in the list of authors. YXY did conceptualization, data curation, formal analysis, investigation, methodology, validation, and visualization, wrote the original draft, and conducted review and editing. RL did conceptualization, data curation, formal analysis, investigation, methodology, validation, and visualization, provided resources, and conducted review editing. FM did conceptualization, data curation, formal analysis, methodology, validation, and visualization, provided resources, and conducted review and editing. JLR did conceptualization, investigation, and methodology, provided resources, and conducted review and editing. ML did conceptualization, investigation, and methodology, provided resources, and conducted review and editing. GB did conceptualization and methodology and conducted review and editing. BM did conceptualization, methodology, and project administration, acquired funding, and conducted review and editing.
Competing interests
The authors declare that they have no conflict of interest.
Disclaimer
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Acknowledgements
We thank the Institut des Régions Arides (IRA) for providing logistics and support during the experiment. Special thanks are expressed to Thierry Henry Des Tureaux for his invaluable help during sampling in Tunisia and to Elisabeth Bon Nguyen, Mickael Tharaud, Anais Feron, Jessica Chane Teng, and Zihan Qu for their advice and help during the analyses. Thanks are given to Carmela Chateau-Smith, who reviewed the English, and to the two anonymous reviewers, who helped us to improve this paper greatly.
Financial support
This work was supported by NILDAE (Nutrients Inputs and Losses Due to Aeolian Erosion in the Sahel), an IdEx Université Sorbonne Paris Cité (now Université de Paris) programme.
Review statement
This paper was edited by Pierre Herckes and reviewed by two anonymous referees.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2021. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
This paper presents a new sampling head design and the method used to evaluate it. The elemental composition of aerosols collected by two different sampling devices in a semi-arid region of Tunisia is compared by means of compositional perturbation vectors and biplots. This set of underused mathematical tools belongs to a family of statistics created specifically to deal with compositional data. The two sampling devices operate at a flow rate in the range of 1
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details

1 Université de Paris, Institut de Physique du Globe de Paris, CNRS, Paris, France
2 ARTEHIS, UMR CNRS 6298, Université Bourgogne-Franche Comté, Dijon, France
3 LISA (Laboratoire Interuniversitaire des Systèmes Atmosphériques), Université de Paris and Univ Paris Est Creteil, CNRS, 75013 Paris, France; iEES Paris (Institut d'Ecologie et des Sciences de l'Environnement de Paris), UMR IRD 242, Univ Paris Est Creteil-Sorbonne Université-CNRS-INRA-Université de Paris, Bondy, France
4 Institut des Régions Arides, Medenine, Tunisia
5 LISA (Laboratoire Interuniversitaire des Systèmes Atmosphériques), Université de Paris and Univ Paris Est Creteil, CNRS, 75013 Paris, France