Background
Ventricular septal rupture (VSR) is a rare but severe complication of acute myocardial infarction (AMI). For such cases, surgical repair is recommended by major guidelines, but not always possible for such cases.
Case presentation
A 72-year-old man presented to the emergency room. ECG showed the ST-segment was elevated by 2–3 mm in lead II, III, and aVF, with Q-waves. Coronary angiography (CAG) showed multi-vessel disease with a total occlusion of the right coronary artery (RCA) and severe stenosis of the left anterior descending artery (LAD). A diagnosis of acute inferior myocardial infarction was made. VSR occurred immediately after percutaneous coronary intervention (a 2.5 × 20 mm drug-eluting stent implanted in RCA), and the patient developed cardiogenic shock. An intra-aortic balloon pump (IABP) was used to stabilize the hemodynamics. Transthoracic echocardiography (TTE) revealed an 11.4-mm left-to-right shunt in the interventricular septum. An attempt was made to reduce the IABP augmentation ratio for weaning on day 12 but failed. Transcatheter closure was conducted using a 24-mm double-umbrella occluder on day 28. The patient was weaned from IABP on day 31 and underwent secondary PCI for LAD lesions on day 35. The patient was discharged on day 41. Upon the last follow-up 6 years later, CAG and TTE revealed no in-stent restenosis, no left-to-right shunt, and 51% left ventricular ejection fraction.
Conclusions
Prolonged implementation of IABP can be a viable option to allow deferred closure of VSR in AMI patients, and transcatheter closure may be considered as a second choice for the selected senior and vulnerable patients, but the risk is still high.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer