Full Text

Turn on search term navigation

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations’ RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 ± 0.11 and 0.28 ± 0.07) followed by LENTIS Mplus 15 (group C, 0.35 ± 0.1 and 0.21 ± 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 ± 0.08 and 0.18 ± 0.06) and Precizon Presbyopic (group D, 0.27 ± 0.07 and 0.17 ± 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.

Details

Title
Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses
Author
Francesco D’Oria 1   VIAFID ORCID Logo  ; Nowrouzi, Ali 2   VIAFID ORCID Logo  ; Jorge L Alio del Barrio 3   VIAFID ORCID Logo  ; Versaci, Francesco 4 ; Alio, Jorge L 3 

 Section of Ophthalmology, Department of Basic Medical Sciences, Neurosciences and Sense Organs, University of Bari, 70124 Bari, Italy; [email protected] 
 Ophthalmology Department of Hospital Quironsalud, 29670 Marbella, Spain; [email protected] 
 Department of Ophthalmology, Miguel Hernandez University, Vissum Miranza, 03015 Alicante, Spain; [email protected] 
 R&D Department, Costruzione Strumenti Oftalmici (CSO), 50018 Florence, Italy; [email protected] 
First page
559
Publication year
2021
Publication date
2021
Publisher
MDPI AG
e-ISSN
23046732
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2612814396
Copyright
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.