Abstract

Background

3D printing is an ideal manufacturing process for creating patient-matched models (anatomical models) for surgical and interventional planning. Cardiac anatomical models have been described in numerous case studies and journal publications. However, few studies attempt to describe wider impact of the novel planning augmentation tool. The work here presents the evolution of an institution’s first 3 full years of 3D prints following consistent integration of the technology into clinical workflow (2012–2014) - a center which produced 79 models for surgical planning (within that time frame). Patient outcomes and technology acceptance following implementation of 3D printing were reviewed.

Methods

A retrospective analysis was designed to investigate the anatomical model’s impact on time-based surgical metrics. A contemporaneous cohort of standard-of-care pre-procedural planning (no anatomical models) was identified for comparative analysis. A post-surgery technology acceptance assessment was also employed in a smaller subset to measure perceived efficacy of the anatomical models. The data was examined.

Results

Within the timeframe of the study, 928 primary-case cardiothoracic surgeries (encompassing both CHD and non-CHD surgeries) took place at the practicing pediatric hospital. One hundred sixty four anatomical models had been generated for various purposes. An inclusion criterion based on lesion type limited those with anatomic models to 33; there were 113 cases matching the same criterion that received no anatomical model. Time-based metrics such as case length-of-time showed a mean reduction in overall time for anatomical models. These reductions were not statistically significant. The technology acceptance survey did demonstrate strong perceived efficacy. Anecdotal vignettes further support the technology acceptance.

Discussion & conclusion

The anatomical models demonstrate trends for reduced operating room and case length of time when compared with similar surgeries in the same time-period; in turn, these reductions could have significant impact on patient outcomes and operating room economics. While analysis did not yield robust statistical powering, strong Cohen’s d values suggest poor powering may be more related to sample size than non-ideal outcomes. The utility of planning with an anatomical model is further supported by the technology acceptance study which demonstrated that surgeons perceive the anatomical models to be an effective tool in surgical planning for a complex CHD repair. A prospective multi-center trial is currently in progress to further validate or reject these findings.

Details

Title
3D printing for congenital heart disease: a single site’s initial three-yearexperience
Author
Ryan, Justin 1   VIAFID ORCID Logo  ; Plasencia, Jonathan 2 ; Richardson, Randy 3 ; Velez, Daniel 4 ; Nigro, John J 5 ; Pophal, Stephen 4 ; Frakes, David 6 

 Rady Children’s Hospital–San Diego, San Diego, USA (GRID:grid.286440.c) (ISNI:0000 0004 0383 2910); Phoenix Children’s Hospital, Phoenix, USA (GRID:grid.417276.1) (ISNI:0000 0001 0381 0779); Arizona State University, Tempe, USA (GRID:grid.215654.1) (ISNI:0000 0001 2151 2636) 
 Phoenix Children’s Hospital, Phoenix, USA (GRID:grid.417276.1) (ISNI:0000 0001 0381 0779); Arizona State University, Tempe, USA (GRID:grid.215654.1) (ISNI:0000 0001 2151 2636) 
 St. Joseph’s Hospital and Medical Center, Phoenix, USA (GRID:grid.240866.e) (ISNI:0000 0001 2110 9177) 
 Phoenix Children’s Hospital, Phoenix, USA (GRID:grid.417276.1) (ISNI:0000 0001 0381 0779) 
 Rady Children’s Hospital–San Diego, San Diego, USA (GRID:grid.286440.c) (ISNI:0000 0004 0383 2910); Phoenix Children’s Hospital, Phoenix, USA (GRID:grid.417276.1) (ISNI:0000 0001 0381 0779) 
 Arizona State University, Tempe, USA (GRID:grid.215654.1) (ISNI:0000 0001 2151 2636) 
Publication year
2018
Publication date
Dec 2018
Publisher
Springer Nature B.V.
e-ISSN
23656271
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2623499371
Copyright
© The Author(s) 2018. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.