© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

The free cantilever method (FCM) is a bridge construction method in which the left and right segments are joined in sequence from a pier without using a bottom strut. To support the imbalance of the left and right moments during construction, temporary steel rods, upon which tensile force is applied that cannot be managed after construction, are embedded in the pier. If there is an excessive loss of tensile force applied to the steel rods, the segments can collapse owing to the unbalanced moment, which may cause personal and property damage. Therefore, it is essential to monitor the tensile force in the temporary steel rods to prevent such accidents. In this study, a tensile force estimation method for the temporary steel rods of an FCM bridge using embedded Elasto-Magnetic (EM) sensors was proposed. After the tensile force was applied to the steel rods, the change in tensile force was monitored according to the changing area of a magnetic hysteresis curve, as measured by the embedded EM sensors. To verify the field applicability of the proposed method, the EM sensors were installed in an FCM bridge pier under construction. The three sensors were installed in conjunction with a sheath tube, and the magnetic hysteresis curve was measured over nine months. Temperature data from the measurement period were used to compensate for the error due to daily temperature fluctuations. The estimated tensile force was consistent with an error range of ±4% when compared with the reference value measured by the load cell. Based on the results of this experiment, the applicability of the proposed method was demonstrated.

Details

Title
Verification of Tensile Force Estimation Method for Temporary Steel Rods of FCM Bridges Based on Area of Magnetic Hysteresis Curve Using Embedded Elasto-Magnetic Sensor
Author
Won-Kyu, Kim 1 ; Kim, Junkyeong 2   VIAFID ORCID Logo  ; Park, Jooyoung 3 ; Ju-Won, Kim 4   VIAFID ORCID Logo  ; Park, Seunghee 5   VIAFID ORCID Logo 

 Equipment Group, Industrial Materials Team 2, Materials Division, Samsung C&T Corporation, Seoul 05510, Korea; [email protected]; Department of Convergence Engineering for Future City, Sungkyunkwan University, Suwon 16419, Korea 
 Safety Inspection for Infrastructure Laboratory (SIIL), Advanced Institute of Convergence Technology, Suwon 16229, Korea 
 Department of the Civil, Architectural and Environmental System Engineering, Sungkyunkwan University, Suwon 16419, Korea; [email protected] 
 Department of Safety Engineering, Dongguk University-Gyeongju, Gyeongju 38066, Korea; [email protected] 
 School of Civil, Architectural Engineering & Landscape Architecture, Sungkyunkwan University, Suwon 16419, Korea; Technical Research Center, Smart Inside AI Co., Ltd., Suwon 16419, Korea 
First page
1005
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
14248220
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2627837042
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.