Abstract
Background
Patients receiving intermittent hemodialysis have variable times of recovery to feeling better after dialysis. QT prolongation, a precursor to clinical and subclinical cardiovascular events, may contribute to delayed recovery time. We hypothesized that abnormal electrocardiographic parameters indicating perturbations in ventricular action are associated with longer recovery times thus impacting a patient-centered quality of life.
Methods
Among 242 incident in-center hemodialysis participants from the Predictors of Arrhythmic and Cardiovascular Risk in End Stage Renal Disease (PACE) study, corrected QT interval (QTc), QRST angle and heart rate variance were measured on non-dialysis days using a standard 5-min electrocardiograph recording. Left ventricular hypertrophy (LVH) was defined using the Cornell voltage product. Recovery time was ascertained during a phone interview with a standardized validated questionnaire. Associations between QTc, QRST angle, heart rate variance, and LVH and natural log-transformed recovery time were examined using linear regression adjusted for participant characteristics and electrolytes.
Results
Mean age was 55 (standard deviation 13) years, 55% were male, 72% were African American. Longer QTc interval was associated with increased recovery time (per 10 ms increase in QTc, recovery time increased by 6.2%; 95% confidence interval: 0.0–10.5). QRST angle, heart rate, heart rate variability and LVH were not significantly associated with recovery time.
Conclusion
Longer QTc intervals are associated with longer recovery time independent of serum electrolytes. This supports a relationship between a patient’s underlying arrhythmic status and time to recovery after hemodialysis. Future studies will determine if maneuvers to reduce QTc improves recovery time and quality of life of patients on hemodialysis.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer