Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

This study assessed the safety and performance of ARTFit, a new tool embedded in MAESTRO, the cochlear implant (CI) system software by MED-EL GmbH (Innsbruck, Austria). ARTFit automatically measures thresholds of the electrically evoked compound action potential (ECAP) to produce initial ‘maps’ (ECAPMAPs), i.e., configuration settings of the audio processor that the audiologist switches to live mode and adjusts for comfortable loudness (LiveECAPMAPs). Twenty-three adult and ten pediatric users of MED-EL CIs participated. The LiveECAPMAPs were compared to behavioral maps (LiveBurstMAPs) and to the participants’ everyday clinical maps (ClinMAPs). Four evaluation measures were considered: average deviations of the maximum comfortable loudness (MCL) levels of the LiveECAPMAPs and the LiveBurstMAPs from the MCLs of the ClinMAPs; correlations between the MCLs of the LiveECAPMAPs (MCLecap) and the LiveBurstMAPs (MCLburst) with the MCLs of the ClinMAPs (MCLclin); fitting durations; and speech reception thresholds (SRTs). All evaluation measures were analyzed separately in the adult and pediatric subgroups. For all evaluation measures, the deviations of the LiveECAPMAPs from the ClinMAPs were not larger than those of the LiveBurstMAPs from the ClinMAPs. The Pearson correlation between the MCLecap and the MCLclin across all channels was r2 = 0.732 (p < 0.001) in the adult and r2 = 0.616 (p < 0.001) in the pediatric subgroups. The mean fitting duration in minutes for the LiveECAPMAPs was significantly shorter than for that of the LiveBurstMAPs in both subgroups: adults took 5.70 (range 1.90–11.98) vs. 9.27 (6.83–14.72) min; children took 3.03 (1.97–4.22) vs. 7.35 (3.95–12.77). SRTs measured with the LiveECAPMAPs were non-inferior to those measured with the ClinMAPs and not statistically different to the SRTs measured with the LiveBurstMAPs. ARTFit is a safe, quick, and reliable tool for audiologists to produce ECAP-based initial fitting maps in adults and young children who are not able to provide subjective feedback.

Details

Title
ARTFit—A Quick and Reliable Tool for Performing Initial Fittings in Users of MED-EL Cochlear Implants
Author
Gärtner, Lutz 1   VIAFID ORCID Logo  ; Bräcker, Timo 2 ; Kals, Mathias 3 ; Penninger, Richard T 3 ; Billinger-Finke, Mareike 3 ; Lenarz, Thomas 1   VIAFID ORCID Logo  ; Büchner, Andreas 1   VIAFID ORCID Logo 

 Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany; [email protected] (T.L.); [email protected] (A.B.) 
 MED-EL Research Center, MED-EL Elektromedizinische Geräte GmbH, 30625 Hannover, Germany; [email protected] 
 MED-EL Elektromedizinische Geräte GmbH, 6020 Innsbruck, Austria; [email protected] (M.K.); [email protected] (R.T.P.); [email protected] (M.B.-F.) 
First page
269
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20751729
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2633099629
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.