Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

The effect of impedance measurements of applied voltage on the detection of 17α-ethinylestradiol (EE2) in water samples using interdigitated electrodes (IDE) coated or not with thin films, is described. Firstly, the effect of immersion in EE2 aqueous solutions of layer-by-layer films prepared with poly(allylamine hydrochloride) (PAH), graphene oxide (GO), poly(1-(4-(3-carboxy-4-hydroxyphenylazo) benzene sulfonamido) 1,2 ethanediyl, sodium salt) (PAZO), polyethylenimine (PEI) and poly(sodium 4-styrenesulfonate) (PSS) was analyzed. These results demonstrated that PAH/GO films desorb during the immersion on EE2 solutions, while EE2 adsorbs on PAH/PAZO and PEI/PSS films with characteristic time values of 16.7 and 7.1 min, respectively, demonstrating that both films are adequate for the development of EE2 sensors. However, as the adsorption characteristic time is shorter, and the EE2 adsorbed amount is smaller, the PEI/PSS films are more suitable for the development of sensors. The effect of the applied voltage was analyzed using both IDEs covered with PEI/PSS films as well as those uncoated. The capacitance spectra are best fitted to analyze this effect, and the loss tangent spectra are advantageous to analyze the aqueous media. Furthermore, it was concluded that lower voltage values are best suited to perform measurements of this nature, given that higher voltages lead to less reliable results and cause irreparable damage to the sensors.

Details

Title
Effect of Applied Electrical Stimuli to Interdigitated Electrode Sensors While Detecting 17α-Ethinylestradiol in Water Samples
Author
Zagalo, Paulo M 1 ; Ribeiro, Paulo A 2   VIAFID ORCID Logo  ; Raposo, Maria 2   VIAFID ORCID Logo 

 CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal; Laboratory of Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UNL), Department of Physics, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; [email protected] 
 Laboratory of Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UNL), Department of Physics, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; [email protected] 
First page
114
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
22279040
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2642365485
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.