© 2022 Agha et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Objectives

Percutaneous patent ductus arteriosus (PDA) stenting is a therapeutic modality in patients with duct-dependent pulmonary circulation with reported success rates from 80–100%. The current study aims to assess the outcome and the indicators of success for PDA stenting in different ductal morphologies using various approaches.

Methods

A prospective cohort study from a single tertiary center presented from January 2018 to December 2019 that included 96 consecutive infants with ductal-dependent pulmonary circulation and palliated with PDA stenting. Patients were divided according to PDA origin into 4 groups: Group 1: PDA from proximal descending aorta, Group 2: from undersurface of aortic arch, Group 3: opposite the subclavian artery, Group 4: opposite the innominate/brachiocephalic artery.

Results

The median age of patients was 22 days and median weight was 3 kg. The procedure was successful in 78 patients (81.25%). PDA was tortuous in 70 out of 96 patients. Femoral artery was the preferred approach in Group 1 (63/67), while axillary artery access was preferred in the other groups (6/11 in Group 2, 11/17 in Group 3, 1/1 in Group 4, P <0.0001). The main cause of procedural failure was inadequate parked coronary wire inside one of the branch of pulmonary arteries (14 cases; 77.7%), while 2 cases (11.1%) were complicated by acute stent thrombosis, and another 2 cases with stent dislodgment. Other procedural complications comprised femoral artery thrombosis in 7 cases (7.2%). Patients with straight PDA, younger age at procedure and who had larger PDA at pulmonary end had higher odds for success (OR = 8.01, 2.94, 7.40, CI = 1.011–63.68, 0.960–0.99, 1.172–7.40,respectively, P = 0.048, 0.031,0.022 respectively).

Conclusions

The approach for PDA stenting and hence the outcome is markedly determined by the PDA origin and morphology. Patients with straight PDA, younger age at procedure and those who had relatively larger PDA at the pulmonary end had better opportunity for successful procedure.

Details

Title
Margin between success and failure of PDA stenting for duct-dependent pulmonary circulation
Author
Agha, Hala Mounir; Abd -El Aziz, Osama; Kamel, Ola; Sheta, Sahar S; El-Sisi, Amal; El-Saiedi, Sonia; Fatouh, Aya; Esmat, Amira; Gaser Abdelmohsen; Baher Hanna; Hussien, Mai; Rodina Sobhy
First page
e0265031
Section
Research Article
Publication year
2022
Publication date
Apr 2022
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2650244596
Copyright
© 2022 Agha et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.