The Authors of the paper “Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing” [1] want to declare the following corrections to their original article.
A first correction has been made in Section 2.3—Test Specimens (Pre- and Post-Curing):
In Table 1, the settings for the Grey Pro resin were reported incorrectly. The correct values should have been 15 min at 80 °C and not 30 min at 60 °C.
Table 1 is enclosed here in its corrected version (the references, included in the original Table 1 and omitted here, can be found in [1]).
A second correction has been made in Section 3.1—Load at Break and Young’s Modulus:
In Table 2, four columns of standard deviation values σ were increased by one decimal place. The last two columns of standard deviation values σ were reported in MPa and not in GPa. The values should have been all divided by 1000.
Table 2 is enclosed here in its corrected version (the references, included in the original Table 2 and omitted here, can be found in [1]).
The Authors apologize for any inconvenience caused by these mistakes. We state that these textual errors did not affect the experimental testing and are inconsequential on the results reported in the remaining parts of the article.
The original article has been updated.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
FormCure settings [4].
Resin | Time (min) | Temperature (°C) |
---|---|---|
Tough | 60 | 60 |
Standard Clear | 15 | 60 |
Grey Pro | 15 | 80 |
BioMed Amber | 30 | 60 |
Dental LT Clear | 60 | 60 |
Tough 1500 | 60 | 70 |
Tough 2000 | 60 | 70 |
Custom Tray | 30 | 60 |
High Temp | 120 | 80 |
Durable | 60 | 60 |
Rigid | 15 | 80 |
Load at break and Young’s modulus values as obtained for each resin. Comparison between green and post-cure conditions. Mean
Load at Break (MPa) | Young’s Modulus (GPa) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Green | Post-Cure | Green | Post-Cure | |||||||||
Data Sheet | Exp. Results | Data Sheet | Exp. Results | Data Sheet | Exp. Results | Data Sheet | Exp. Results | |||||
Resin |
|
σ |
|
σ |
|
σ |
|
σ | ||||
Tough | 34.7 [22] | 23.5 | 1.83 | 55.7 [22] | 30.4 | 22.17 | 1.7 [22] | 0.3 | 0.03 | 2.7 [22] | 0.6 | 0.08 |
Standard Clear | 38.0 [23] | 20.1 | 2.17 | 65.0 [23] | 42.2 | 1.91 | 1.6 [23] | 0.7 | 0.09 | 2.8 [23] | 1.0 | 0.03 |
Grey Pro | 35.0 [24] | 32.2 | 5.68 | 61.0 [24] | 60.4 | 1.90 | 1.4 [24] | 0.8 | 0.02 | 2.6 [24] | 1.0 | 0.03 |
BioMed Amber | N.A. [25] | 41.2 | 1.04 | 73.0 [25] | 76.8 | 4.09 | N.A. [25] | 0.8 | 0.02 | 2.9 [25] | 1.2 | 0.02 |
Dental LT Clear | N.A. [26] | 34.6 | 1.89 | 61.8 | 10.69 | N.A. [26] | 0.6 | 0.04 | - (*) | - (*) | ||
Tough 1500 | 26.0 [27] | 30.4 | 2.63 | 33.0 [27] | 41.2 | 0.96 | 0.9 [27] | 0.4 | 0.02 | 1.5 [27] | 0.6 | 0.01 |
Tough 2000 | 29.0 [28] | 26.5 | 0.41 | 46.0 [28] | 42.0 | 1.43 | 1.2 [28] | 0.4 | 0.04 | 2.2 [28] | 0.8 | 0.02 |
Custom Tray | N.A. [29] | 26.9 | 1.98 | 84.7 | 2.43 | N.A. [29] | 0.4 | 0.01 | 1.1 | 0.01 | ||
High Temp | 20.9 [30] | 26.2 | 0.30 | 58.3 [30] | 48.2 | 7.90 | 0.8 [30] | 0.3 | 0.01 | 2.8 [30] | 0.8 | 0.00 |
Durable | 18.6 [31] | 17.0 | 0.79 | 31.8 [31] | 34.5 | 1.34 | 0.5 [31] | 0.2 | 0.03 | 1.3 [31] | 0.4 | 0.01 |
BioMed Clear | N.A. [32] | 30.9 | 1.87 | 52.0 [32] | 60.1 | 0.55 | N.A. [32] | 0.4 | 0.02 | 2.1 [32] | 0.9 | 0.02 |
Rigid | 40.0 [33] | 39.8 | 3.07 | 75.0 [33] | 74.5 | 7.69 | 2.2 [33] | 0.7 | 0.02 | 4.1 [33] | 1.3 | 0.18 |
(*) After curing, the Dental LT Clear Resin became fragile to such an extent that it broke during clamping, making the experimental test unfeasible.
Reference
1. Riccio, C.; Civera, M.; Ruiz, O.G.; Pedullà, P.; Reinoso, M.R.; Tommasi, G.; Vollaro, M.; Burgio, V.; Surace, C. Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing. Appl. Mech.; 2021; 2, pp. 942-955. [DOI: https://dx.doi.org/10.3390/applmech2040055]
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
The Authors of the paper “Effects of Curing on Photosensitive Resins in SLA Additive Manufacturing” [1] want to declare the following corrections to their original article. A second correction has been made in Section 3.1—Load at Break and Young’s Modulus: In Table 2, four columns of standard deviation values σ were increased by one decimal place. Load at Break (MPa) Young’s Modulus (GPa) Green Post-Cure Green Post-Cure Data Sheet Exp. Results Data Sheet Exp. Results Data Sheet Exp. Results Data Sheet Exp. Results Resin X ¯ σ X ¯ σ X ¯ σ X ¯ σ Tough 34.7 [22] 23.5 1.83 55.7 [22] 30.4 22.17 1.7 [22] 0.3 0.03 2.7 [22] 0.6 0.08 Standard Clear 38.0 [23] 20.1 2.17 65.0 [23] 42.2 1.91 1.6 [23] 0.7 0.09 2.8 [23] 1.0 0.03 Grey Pro 35.0 [24] 32.2 5.68 61.0 [24] 60.4 1.90 1.4 [24] 0.8 0.02 2.6 [24] 1.0 0.03 BioMed Amber N.A. [25] 41.2 1.04 73.0 [25] 76.8 4.09 N.A. [25] 0.8 0.02 2.9 [25] 1.2 0.02 Dental LT Clear N.A. [26] 34.6 1.89 ≥50.0 [26] 61.8 10.69 N.A. [26] 0.6 0.04 ≥1.3 [26] - (*) - (*) Tough 1500 26.0 [27] 30.4 2.63 33.0 [27] 41.2 0.96 0.9 [27] 0.4 0.02 1.5 [27] 0.6 0.01 Tough 2000 29.0 [28] 26.5 0.41 46.0 [28] 42.0 1.43 1.2 [28] 0.4 0.04 2.2 [28] 0.8 0.02 Custom Tray N.A. [29] 26.9 1.98 ≥70.0 [29] 84.7 2.43 N.A. [29] 0.4 0.01 ≥2.5 [29] 1.1 0.01 High Temp 20.9 [30] 26.2 0.30 58.3 [30] 48.2 7.90 0.8 [30] 0.3 0.01 2.8 [30] 0.8 0.00 Durable 18.6 [31] 17.0 0.79 31.8 [31] 34.5 1.34 0.5 [31] 0.2 0.03 1.3 [31] 0.4 0.01 BioMed Clear N.A. [32] 30.9 1.87 52.0 [32] 60.1 0.55 N.A. [32] 0.4 0.02 2.1 [32] 0.9 0.02 Rigid 40.0 [33] 39.8 3.07 75.0 [33] 74.5 7.69 2.2 [33] 0.7 0.02 4.1 [33] 1.3 0.18 (*) After curing, the Dental LT Clear Resin became fragile to such an extent that it broke during clamping, making the experimental test unfeasible.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer