Full Text

Turn on search term navigation

© 2022 Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See:  http://creativecommons.org/licenses/by-nc/4.0/ . Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background

Accurate detection of SARS-CoV-2 is necessary to mitigate the COVID-19 pandemic. However, the test reagents and assay platforms are varied and may not be sufficiently robust to diagnose COVID-19.

Methods

We reviewed 85 studies (21 530 patients), published from five regions of the world, to highlight issues involved in the diagnosis of COVID-19 in the early phase of the pandemic. All relevant articles, published up to 31 May 2020, in PubMed, BioRiXv, MedRiXv and Google Scholar, were included. We evaluated the qualitative (9749 patients) and quantitative (10 355 patients) performance of RT-PCR and serologic diagnostic tests for real-world samples, and assessed the concordance (5538 patients) between test performance in meta-analyses. Synthesis of results was done using random effects modelling and bias was evaluated according to QUADAS-2 guidelines.

Results

The RT-PCR tests exhibited heterogeneity in the primers and reagents used. Of 1957 positive RT-PCR COVID-19 participants, 1585 had positive serum antibody (IgM±IgG) tests (sensitivity 0.81, 95% CI 0.66 to 0.90). While 3509 of 3581 participants RT-PCR negative for COVID-19 were found negative by serology testing (specificity 0.98, 95% CI 0.94 to 0.99). The chemiluminescent immunoassay exhibited the highest sensitivity, followed by ELISA and lateral flow immunoassays. Serology tests had higher sensitivity and specificity for laboratory approval than for real-world reporting data.

Discussion

The robustness of the assays/platforms is influenced by variability in sampling and reagents. Serological testing complements and may minimise false negative RT-PCR results. Lack of standardised assay protocols in the early phase of pandemic might have contributed to the spread of COVID-19.

Details

Title
Meta-analysis of the robustness of COVID-19 diagnostic kit performance during the early pandemic
Author
Shanmugam, Chandrakumar 1   VIAFID ORCID Logo  ; Behring, Michael 2 ; Luthra, Vishwas 3   VIAFID ORCID Logo  ; Leal, Sixto M 4 ; Varambally, Sooryanarayana 4 ; Netto, George J 4 ; Manne, Upender 5   VIAFID ORCID Logo 

 Pathology, MNR Medical College and Hospital, Sangareddy, Telangana, India 
 Department of Pathology at UAB, The University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA 
 Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, Punjab, India 
 Department of Medicine, The University of Alabama at Birmingham, Birmingham, Alabama, USA 
 Pathology, The University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA 
First page
e053912
Section
Infectious diseases
Publication year
2022
Publication date
2022
Publisher
BMJ Publishing Group LTD
e-ISSN
20446055
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2666297864
Copyright
© 2022 Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See:  http://creativecommons.org/licenses/by-nc/4.0/ . Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.