Abstract

In response to the COVID-19 pandemic, lateral flow assays (LFAs) for the detection of SARS-CoV-2 antigen have been proposed as a complementary option to the more costly and time consuming reverse-transcriptase polymerase chain reaction (RT-PCR). We assessed five commercially available SARS-CoV-2 antigen detecting LFAs (ASSUT EUROPE (Rome, Italy), Besthree (Taizhou, China), Encode (Zhuhai, China), Fortress (Antrim UK), and Hughes Medical (Buckinghamshire, UK), using samples collected from hospitalised individuals with COVID-19 and compared these results against established RT-PCR assays with the aim of estimating test performance characteristics. We performed a diagnostic accuracy study of the five LFAs on 110 inpatients with confirmed COVID-19 and 75 COVID-19 negative control participants. Assay evaluation was performed using a modified version of each manufacturer’s protocol allowing for parallel testing of a single sample on multiple assays. Additional variables were studied including infection acquisition, oxygenation requirements at time of swabbing, and patient outcomes. The 110 patients were 48% (53) female, with mean age 67 years (range 26–100 years), and 77% (85) cases were community onset SARS-CoV-2. Across the five assays, sensitivity ranged from 64 (95% CI 53–73) to 76% (95% CI 65–85); Fortress performed best with sensitivity of 76% (95% CI 65–85). Specificity was high across all assays with 4/5 LFAs achieving 100%. LFA sensitivity was not dependant on RT-PCR cycle thresholds. SARS-CoV-2 antigen detecting LFAs may complement RT-PCR testing to facilitate early diagnosis and provide community testing strategies for identification of patients with COVID-19, however we find suboptimal test performance characteristics across a range of commercially available manufacturers, below WHO and MHRA pre-set sensitivity performance thresholds. With such variation in sensitivity between LFAs and PCR testing and between assay brands, we advise caution in the deployment of LFAs outside of environments with clinical oversight.

Details

Title
Evaluating the performance characteristics of five lateral flow assays for the detection of the SARS-CoV-2 nucleocapsid antigen
Author
Heskin, J 1 ; Pallett, S J, C 2 ; Al-Hindawi, A 1 ; Davies, G W 1 ; Rayment, M 1 ; Mughal, N 3 ; Randell, P 4 ; Jones, R 1 ; Moore L S P 5 

 Chelsea and Westminster NHS Foundation Trust, London, UK (GRID:grid.428062.a) (ISNI:0000 0004 0497 2835) 
 Queen Elizabeth Hospital Birmingham, Centre of Defence Pathology, Royal Centre for Defence Medicine, Birmingham, UK (GRID:grid.415490.d) (ISNI:0000 0001 2177 007X) 
 Chelsea and Westminster NHS Foundation Trust, London, UK (GRID:grid.428062.a) (ISNI:0000 0004 0497 2835); Imperial College Healthcare NHS Trust, North West London Pathology, London, UK (GRID:grid.417895.6) (ISNI:0000 0001 0693 2181) 
 Imperial College Healthcare NHS Trust, North West London Pathology, London, UK (GRID:grid.417895.6) (ISNI:0000 0001 0693 2181) 
 Chelsea and Westminster NHS Foundation Trust, London, UK (GRID:grid.428062.a) (ISNI:0000 0004 0497 2835); Imperial College Healthcare NHS Trust, North West London Pathology, London, UK (GRID:grid.417895.6) (ISNI:0000 0001 0693 2181); Imperial College London, NIHR Health Protection Research Unit in Healthcare Associated Infections & Antimicrobial Resistance, London, UK (GRID:grid.7445.2) (ISNI:0000 0001 2113 8111) 
Publication year
2022
Publication date
2022
Publisher
Nature Publishing Group
e-ISSN
20452322
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2669224848
Copyright