Full text

Turn on search term navigation

© 2022 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

This work determined the attenuation coefficients of Lamb waves of ten engineering materials and compared the results with calculated Lamb-wave attenuation coefficients, α–S and α–A. The Disperse program and a parametric method based on Disperse results were used for calculations. Bulk-wave attenuation coefficients, αL and αT, were required as input parameters to the Disperse calculations. The calculated α–S and α–A values were found to be dominated by the αT contribution. Often α–Ao coincided with αT. The values of αL and αT were previously obtained or newly measured. Attenuation measurement relied on Lamb-wave generation by pulsed excitation of ultrasonic transducers and on surface-displacement detection with point contact receivers. The frequency used ranged from 10 kHz to 1 MHz. A total of 14 sheet and plate samples were evaluated. Sample materials ranged from steel, Al, and silicate glass with low attenuation to polymers and a fiber composite with much higher attenuation. Experimentally obtained Lamb-wave attenuation coefficients, α–S and α–A, for symmetric and asymmetric modes, were mostly for the zeroth mode. Plots of α–So and α–Ao values against frequency were found to coincide reasonably well to theoretically calculated curves. This study confirmed that the Disperse program predicts Lamb-wave attenuation coefficients for elastically isotropic materials within the limitation of the contact ultrasonic techniques used. Further refinements in experimental methods are needed, as large deviations often occurred, especially at low and high frequencies. Methods of refinement are suggested. Displacement measurements were quantified using Rayleigh wave calibration. For signals below 300 kHz, 1-mV receiver output corresponded to 1-pm displacement. Peak displacements after 200-mm propagation were found to range from 10 pm to 1.5 nm. With the use of signal averaging, the point-contact sensor was capable of detecting 1-pm displacement with 40 dB signal-to-noise ratio and had equivalent noise of 4.3 fm/√Hz. Approximate expressions for α–So and α–Ao were obtained, and an empirical correlation was found between bulk-wave attenuation coefficients, i.e., αT = 2.79 αL, for over 150 materials.

Details

Title
Experimental Determination of Lamb-Wave Attenuation Coefficients
Author
Ono, Kanji  VIAFID ORCID Logo 
First page
6735
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
20763417
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2685976086
Copyright
© 2022 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.