Full Text

Turn on search term navigation

© 2022 Pagès et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Objectives

To evaluate long-term outcome using the BioMedtrix™ TPLO Curve® plate in dogs with cranial cruciate ligament disease (CrCLd) treated by tibial plateau leveling osteotomy (TPLO).

Study design

Retrospective case study.

Animals

Dogs (n = 323, 337 stifles).

Methods

Medical records were searched for dogs presented with CrCLd and treated by TPLO with the BioMedtrix™ TPLO Curve® plate for 3.5 mm screws between March 2018 and December 2020. Tibial plateau angles (TPA) were measured on preoperative, postoperative, and follow-up radiographs. Changes in TPA between postoperative and follow-up radiographs (ModTPA) were calculated. Radiographic bone healing was scored. Complications were evaluated. Surgical site infections (SSI) were compared to a control group of dogs treated with the Synthes™ TPLO plate between January and December 2017. Owners of both groups were contacted by telephone at least 1 year postoperatively.

Results

The BioMedtrix™ group was composed of 237 dogs (248 stifles), the control group was composed of 86 dogs (89 stifles). In the BioMedtrix™ group, radiographic follow-up was performed at a median of 48 days. Average ModTPA was 1.2°. Bone healing was graded as complete, good, poor, and none in 18%, 62%, 20%, and 0%, respectively. At a median of 786 days postoperatively, minor and major postoperative complications were observed in 6 (2.4%) and 32 (12.9%) cases in this group, respectively. During the first year following the surgery, 23 (9.3%) and 12 (13.5%) cases suffered a SSI, of which 12 (4.8%) and 7 (7.9%) had their implant explanted in the BioMedtrix™ group and the control group, respectively. There was no significant difference between groups for SSI and implant explantations (p = 0.31 and p = 0.29, respectively).

Conclusion

The BioMedtrix™ TPLO Curve® plate provided a reliable fixation system for osteotomy healing after TPLO. Bone healing and long-term complication rates were similar to previous studies using other implants. SSI rates were similar between the BioMedtrix™ group and the control group. The antimicrobial HyProtect® coating of the plate did not reduce SSI in this study.

Clinical significance

The BioMedtrix™ TPLO Curve® plate can be safely used for TPLO. The value of the antimicrobial HyProtect® coating of the plate may be questioned, as SSI rate was not lower in this study compared to the control group or previous reports.

Details

Title
Long-term outcome of tibial plateau leveling osteotomy using an antimicrobial silver-based coated plate in dogs
Author
Pagès, Geoffrey  VIAFID ORCID Logo  ; Hammer, Meike; Jean-Guillaume Grand; Irubetagoyena, Iban
First page
e0272555
Section
Research Article
Publication year
2022
Publication date
Aug 2022
Publisher
Public Library of Science
e-ISSN
19326203
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2701492812
Copyright
© 2022 Pagès et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.