Abstract
Quantitative assessment of the right-to-left ratio of pulmonary blood flow distribution is important for determining the clinical indications for treating pulmonary arterial branch stenosis. A novel theory was recently proposed that can be used to quantitatively assess the right-to-left ratio on conventional X-ray angiography images. In the proposal, further developments were indicated, especially automated calculation. In this study, a new automated algorithm was developed. In the X-ray image, regions of interest were set in right and left lung, and time-signal intensity curves were measured. The new automated algorithm is applied to determine the optimal time window for the analysis of the time-signal intensity curve and to calculate the slope of the curve in the optimized time window. The right-to-left ratios in seven consecutive patients calculated by the new automated algorithm were compared to those calculated by lung perfusion scintigraphy. The ratios were in good agreement with linear regression with a slope of 1.27 and a Pearson correlation coefficient of 0.95. The processing time was less than 10 s, which is one-eighth of the manual processing time. The new automated algorithm is accurate, stable, and fast enough for clinical use in the real world.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Canon Medical Systems Corporation, Otawara, Japan
2 Nagano Children’s Hospital, Department of Pediatric Cardiology, Azumino, Japan (GRID:grid.416376.1) (ISNI:0000 0004 0569 6596)
3 Nagano Children’s Hospital, Department of Pediatric Cardiology, Azumino, Japan (GRID:grid.416376.1) (ISNI:0000 0004 0569 6596); Aizawa Hospital, Echo Center, Matsumoto, Japan (GRID:grid.413462.6) (ISNI:0000 0004 0640 5738)