© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Among the alternatives for improving the thermal comfort conditions inside buildings are the thermally activated building systems (TABS). They are embedded in different building components to improve the indoor air temperature. In this work, a review and analysis of the state of the art of TABS was carried out to identify their potential to improve thermal comfort conditions and provide energy savings. Furthermore, this study presents the gaps identified in the literature so that researchers can develop future studies on TABS. The articles found were classified and analyzed in four sections, considering their implementation in roofs, walls, floors, and the whole envelope. In addition, aspects related to the configuration of the TABS and the fluid (speed, temperature, and mass flow rate) were analyzed. It was found that when TABS are implemented in roofs, walls, and floors, a reduction in the indoor temperature of a building of up to 14.4 °C can be obtained. Within the limitations of the TABS, the complexity and costs of their implementation compared to the use of air conditioning systems are reported. However, the TABS can provide energy savings of up to 50%.

Details

Title
A Review of Thermally Activated Building Systems (TABS) as an Alternative for Improving the Indoor Environment of Buildings
Author
Villar-Ramos, María M 1   VIAFID ORCID Logo  ; Hernández-Pérez, Iván 2   VIAFID ORCID Logo  ; Aguilar-Castro, Karla M 2   VIAFID ORCID Logo  ; Zavala-Guillén, Ivett 3 ; Macias-Melo, Edgar V 2 ; Hernández-López, Irving 4 ; Serrano-Arellano, Juan 5 

 Doctorado en Ciencias en Ingeniería, División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco (DAIA-UJAT), Carretera Cunduacán-Jalpa de Méndez km. 1, Cunduacán 86690, Tabasco, Mexico 
 División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco (DAIA-UJAT), Carretera Cunduacán-Jalpa de Méndez km. 1, Cunduacán 86690, Tabasco, Mexico 
 Centro de Investigación Científica y de Educación Superior de Ensenada CICESE, Carretera Ensenada-Tijuana No. 3918, Zona Playitas, Ensenada 22860, Baja California, Mexico 
 Departamento de Ingeniería Química y Metalurgia, Universidad de Sonora (UNISON), Blvd. Luis Encinas y Rosales S/N, Col. Centro, Hermosillo 83000, Sonora, Mexico 
 División de Estudios de Posgrado e Investigación, Tecnológico Nacional de México/IT de Pachuca, Carretera Mexico-Pachuca km. 87.5, Colonia Venta Prieta, Pachuca de Soto 42080, Hidalgo, Mexico 
First page
6179
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
19961073
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2711306976
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.