© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background and Objectives: Chronic atrial stimulation might impair left atrial (LA) function. We aimed to assess the impact of atrial pacing burden on LA volumetric and functional parameters after implantation of a dual-chamber pacemaker. Materials and Methods: The prospective study included 121 subjects with sinus node disease (SND) or atrioventricular block (AVB) that received a dual-chamber pacemaker. After device implantation, the subjects were divided into three groups: (1) SND with a lower rate (LR) set to 60 bpm and rate response enabled; (2) AVB with an LR set to 60 bpm and no rate response; and (3) AVB with an LR set to 40 bpm and no rate response. Subjects were followed at one and three months. Two subsets of patients with high and low atrial pacing burdens accompanied by low ventricular pacing percentage were analyzed. LA function was evaluated with volumetric and strain parameters from transthoracic echocardiography. Results: The high atrial low ventricular pacing group consisted of 38 subjects, and the low atrial low ventricular group consisted of 22 subjects. When looking at the change in volumetric parameters, we observed a tendency for volumes to increase in both groups; however, only minimal LA volume reached statistical significance at three months in the high atrial pacing group. A trend towards the lowering of an active emptying fraction at one month (p = 0.076) became significant at three months (p = 0.043), and was also only observed in the same group. Moreover, a decrease in the tendency to reach statistical significance at three months for reservoir and contractile strain parameters and stiffness index was only observed in the high atrial pacing group. Meanwhile, in the low atrial pacing burden group, all parameters remained significantly unchanged. Conclusions: The burden of right atrial pacing in patients with preserved left ventricular function negatively influences functional and morphologic LA parameters. Moreover, negative effects take place soon after pacemaker implantation and appear to be sustained.

Details

Title
Atrial Pacing Affects Left Atrial Morphological and Functional Parameters Early after Pacemaker Implantation
Author
Viezelis, Mindaugas 1 ; Neverauskaite-Piliponiene, Gintare 1 ; Marcinkeviciene, Agne 1 ; Teleisyte, Eligija 1 ; Kazakevicius, Tomas 1 ; Zabiela, Vytautas 1 ; Kviesulaitis, Vilius 2 ; Jurkevicius, Renaldas 1 ; Aras Puodziukynas 1 

 Department of Cardiology, Lithuanian University of Health Sciences, A. Mickeviciaus Str. 7, LT-44307 Kaunas, Lithuania 
 Department of Cardiology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu Str. 2, LT-50161 Kaunas, Lithuania 
First page
1283
Publication year
2022
Publication date
2022
Publisher
MDPI AG
ISSN
1010660X
e-ISSN
16489144
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2716574061
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.