This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1. Introduction
The atlantoaxial junction is a specialized region that plays an important role in the movements at the cervico-vertebral joint. Although the atlantoaxial junction is one of the most stable joints in the body, it remains vulnerable to trauma, rheumatoid arthritis, infections, congenital malformations, and malignancies [1]. The resulting deterioration of the zygapophyseal joint, ligament, or muscles between the atlas (C1) and axis (C2) can cause excessive movement and instability at this junction, resulting in atlantoaxial dislocation (AAD). It can cause neck pain and spinal cord compression, and even irreversible neurological deficits, such as cervical myelopathy, paresis, and respiratory dysfunction. For AAD patients with persistent neck pain and neurologic symptoms, surgical intervention is a good choice. Many different surgical techniques have been developed to stabilize the atlantoaxial complex and achieve spinal cord decompression. Currently, Goel-Harm’s technique of C1 lateral mass screw (C1LMS) and C2 pedicle screw (C2PS) is the preferred one because of the lower risk of vertebral artery (VA) injury and minimal damage to facet joints [2]. However, the anatomy of the upper cervical spine is highly variable, and the presence of peripheral neurovascular abnormalities makes atlantoaxial arthrodesis technically challenging [3]. The mean incidence of VA injury caused by misplacement of pedicle screws during atlantoaxial fusion was 8.2% to 21.6% under intraoperative biplane fluoroscopy [4, 5]. To avoid these complications, several advanced techniques have been introduced for assisting screw placement during upper cervical fixation [6–8].
Surgical robotics is widely applied in general surgery, urology, neurosurgery, and orthopedics [9]. In thoracolumbar surgery, robotic assistance (RA) has been shown to improve screw placement accuracy, reduce surgical bleeding, and minimize intraoperative radiation [7, 10]. Nevertheless, there are no reports evaluating the accuracy, efficiency, and safety of robot-assisted posterior atlantoaxial arthrodesis due to the lack of specialized robotic systems for cervical spine surgery. Our medical center installed the intraoperative 3D image-based TiRobot system for orthopedic surgery in 2018. In this study, we have briefly described the robotic structures and workflow and presented the preliminary results of a retrospective study comparing the radiological and clinical results of C1–C2 screw placement using fluoroscopy or RA.
2. Materials and Methods
2.1. Patient Demographics
The study protocol was approved by the ethics committees of Guangdong Provincial Hospital of Chinese Medicine, and the requirement for informed consent was waived due to the retrospective nature of this study. Consecutive patients were diagnosed with AAD and surgically treated with posterior C1–C2 screw fixation under fluoroscopic guidance or RA at our hospital from August 2014 to March 2021. All procedures were performed by the same surgical team. The clinical variables including age, gender, body mass index (BMI), and medical history (symptom duration and pathology) are summarized in Table 1.
Table 1
Comparison of the patients’ demographic characteristics.
FH group ( | RA group ( | ||
Age (years) | 0.46 | ||
Gender (n) | |||
Male | 10 | 6 | 0.38 |
Female | 4 | 5 | |
BMI (kg/m2) | 0.302 | ||
Symptom duration (months) | 0.41 | ||
Postoperative hospital stay (days) | 0.38 | ||
Follow-up time (months) | 0.45 | ||
Pre-JOA | 0.79 | ||
Pre-ODI | 0.85 | ||
Pathology | |||
Trauma | 5 | 4 | 0.98 |
Degeneration | 3 | 2 | |
Congenital malformation | 3 | 3 | |
RA | 3 | 2 | |
Tumor | 0 | 0 |
Data are presented as
2.2. Surgical Techniques
Based on the guiding technique for screw placement, the patients were divided into the conventional fluoroscopy-guided free-hand (FH) group and the RA group using intraoperative robotic navigation devices. Our institute installed TiRobot (co-designed by Beijing Jishuitan Hospital and TINAVI Medical Technologies Co., Ltd.), a novel system consisting of a robotic arm, an optical tracking system, a robotic workstation, and a navigation toolkit for posterior atlantoaxial internal fixation based on intraoperative 3D images. In order to detect neurological function and avoid spinal injury, motor evoked potentials (MEPs) and somatosensory evoked potentials (SEPs) were monitored throughout surgery.
2.2.1. Fluoroscopy-Guided FH Surgery
Following general anesthesia, the patient was placed in the prone position with a radiolucent Mayfield clamp to keep the neck slightly flexed. Then, a posterior median incision was made from the base of the skull to C4. After exposing the posterior arch of C1, the lateral of C1, and the C1–C2 facet joint, fixation was performed with Goel-Harm’s technique [11]. Using direct visualization and anteroposterior and lateral fluoroscopy (BV Endura; Philips, Eindhoven, Netherlands), starting holes were made in the lateral mass of C1 and in the pedicle of C2, respectively. Subsequently, the pilot hole is drilled under fluoroscopic guidance and verification of depth with a blunt probe. After that, the screws (DePuy Synthes, Raynham, Massachusetts, USA) were implanted under X-ray guidance, followed by the placement of 2 rods of appropriate length for connecting C1 and C2. Finally, the spinal canal was decompressed, and posterolateral fusion was performed with iliac crest bone grafting.
2.2.2. RA Surgery
Robot-assisted posterior atlantoaxial internal fixation was performed as previously described by Tian et al. [12] with minor modifications (Figure 1). The TiRobot system was arranged in the operating room as shown in Figure S1. The patients were anesthetized and positioned as in traditional surgery. The patient tracker was securely anchored onto the Mayfield head frame, and the registration was installed and placed into the operating area. The posterior region of the C1–C2 complex was exposed via a midline incision in a standard subperiosteal manner. Following adjustment of the camera position towards the operation space and the patient tracker, the registration was installed and placed into the operating area. A set of images were obtained by intraoperative 3D C-arm scanning, and the trajectories, diameters, and lengths of C1LMS and C2PS were planned according to these images in the robotic station. Subsequently, the robotic arm was moved automatically to guide the planned trajectory, and a cannula was inserted through the sleeve of the robotic arm, followed by drilling of the K-wire into the vertebrae. Following the verification of the optimal path, a cannulated screw was instrumented along the K-wire and the other three screws were inserted in the same manner. The screw position was confirmed, followed by screw-rod connection and bone graft fusion.
[figure(s) omitted; refer to PDF]
2.3. Assessment of Surgical Data
Surgery-related parameters including surgical duration, EBL, radiation dosage, and fusion rate were recorded, along with the length of postoperative hospital stay and follow-up. Vascular and neural complications associated with screw insertion were also evaluated.
2.4. Evaluation of Screw Placement Accuracy
Computed tomography (CT) scan with multiplanar reconstructions of the cervical spine was performed 2 days after surgery to determine the accuracy of screw placement. Two independent observers evaluated the CT images in a blinded manner to determine the number of misplaced screws and the grade of screw placement. The accuracy of screw placement was assessed using a grading system proposed by Gertzbein and Robbins [13]: grade 0, when a screw was completely placed inside the bone; grade I, screw perforation of the cortex <2 mm; grade II, screw perforation ≥2 but <4 mm; and grade III, screw perforation ≥4 mm (Figure S2). Screws graded 0 and I are clinically acceptable, while those graded II and III are significantly deviated from the intended trajectory and can potentially cause neurovascular damage. CT angiography (CTA) or magnetic resonance angiography (MRA) was immediately performed for patients with malpositioned screws to assess potential VA injury.
2.5. Clinical Recovery Assessment
Functional outcomes were assessed 1 week, 1 month, 3 months, and 6 months postsurgery in terms of Japanese Orthopaedic Association (JOA) and visual analogue scale (VAS) scores. The satisfaction rate of clinical outcomes at the final follow-up was assessed according to the modified MacNab criteria (excellent, good, fair, or poor). The scores were calculated by two trained observers. In case of disagreement, a third senior surgeon was asked to assist in the evaluation.
2.6. Statistical Analysis
Statistical analyses were performed using the statistical package SPSS version 20.0 (IBM Corporation, Somers, NY, USA). All continuous variables were presented as
3. Results
3.1. Demographic and Clinical Characteristics
From August 2014 to March 2021, a total of 25 patients underwent posterior C1–C2 screw fixation, including 14 with fluoroscopy-guided FH surgery (
3.2. Comparison of Surgical Results between the Two Groups
The intraoperative period was uneventful in all patients. Mean EBL was
Table 2
Comparison of patients’ operative parameters.
Parameters | FH group ( | RA group ( | |
EBL (ml) | 0.03 | ||
Surgical duration (min) | 0.15 | ||
Radiation dosage (mGy/screw) | 0.01 | ||
Fusion rate, unfused/fused (%) | 1/13 (92.9) | 0/11 (100) | 0.37 |
Data are presented as
[figure(s) omitted; refer to PDF]
3.3. Comparison of the Screw Placement Accuracy
A total of 100 screws, including 50 C1LMS and 50 C2PS, were placed and analyzed using thin-slice CT scan. The accuracy of screw positions is summarized in Table 3. In the RA group, a completely intrabone course (grade 0) was found in 84.1% (
Table 3
Accuracy of the screw position according to the grading system.
Grade 0 | Grade I | Grade II | Grade III | |
FH group | ||||
C1LMS (28 screws) | 21 | 4 | 2 | 1 |
C2PS (28 screws) | 20 | 4 | 3 | 1 |
Total (56 screws) | 41 | 8 | 5 | 2 |
Accuracy rate (%) | 73.2 | 14.3 | 8.9 | 3.6 |
RA group | ||||
C1LMS (22 screws) | 18 | 3 | 1 | 0 |
C2PS (22 screws) | 19 | 1 | 2 | 0 |
Total (44 screws) | 37 | 4 | 3 | 0 |
Accuracy rate (%) | 84.1 | 9.1 | 6.8 | 0 |
3.4. Comparison of the Clinical Recovery Outcomes
Patients were followed for a median period of 11.56 months (range 6–24 months). As shown in Figure 3, both groups showed significant improvements in JOA scores at all follow-up time points in comparison to baseline levels. The improvement rate of JOA score was
[figure(s) omitted; refer to PDF]
Serious complications such as neurovascular injury or cerebrospinal fluid leakage due to the screw fixations were not observed in either group. No wound hematomas, infections, and other perioperative complications were found. Only one case of postoperative delirium was observed in the FH group, and the symptoms were recovered spontaneously after 24 hours.
4. Discussion
Vital structures such as the vertebral arteries and spinal cord are in close proximity to the atlantoaxial joint. The axis vertebra demonstrates high anatomical variations such as narrow pedicle sizes and high-riding VA (HRVA) [14]. As a result, screw placement is a highly risky procedure that may result in screw perforations and increase the risk of neurovascular injury [15, 16]. For spinal surgery, accurate screw placement depends on the selection of correct insertion point, monitoring of the trajectory position, and the surgeons’ skills. However, surgeries involving the cervical spine are prolonged and tedious, which can lead to both mental and physical fatigue, and increase the risk of potentially catastrophic errors. Furthermore, traditional posterior atlantoaxial screw placement requires extensive soft-tissue dissection to distinguish the anatomical features and repeated use of the C-arm X-ray machine to confirm the position of screws. Therefore, it is crucial to develop a procedure that is minimally invasive and can achieve high screw placement accuracy with lower intraoperative radiation exposure. Costa et al. [17] reported that 92.6% of the screws were correctly placed in 17 patients with C1–C2 traumatic fractures who underwent surgery guided by the intraoperative 3D image-based navigation system. Jacobs et al. [18] also presented similar results and suggested that intraoperative CT-based navigation is a viable tool for detecting screw misplacement. Although navigation improves the accuracy, it might require repeated adjustments of the trajectories [19] when inserting screws, which is inconvenient and increases the risk of C2 nerve stimulation and spinal canal invasion.
Robotic systems can perform repetitive tasks with precision and reproducibility, making them ideal for spinal surgery. In the last few decades, nearly 20 robotic systems have been developed for spinal surgery and tested in clinical studies, including Spine Assist (Mazor Robotics Inc®, Orlando, Florida), ROSA (Medtech S.A., Montpellier, France), and Da Vinci Surgical System (Intuitive Surgical). However, these systems can only be used for thoracic and lumbar surgery due to their bone-mounted design and inability to meet the screw placement accuracy required for cervical surgery [9]. TiRobot is currently the only orthopedic robot system that can be used for posterior screw insertion in the cranio-cervical junction area [7, 8, 20]. Although there are case reports of the TiRobot system for C1–C2 transarticular screw fixation and anterior odontoid screw fixation [8, 21], studies evaluating radiological results and clinical outcomes of robotic-assisted posterior C1–C2 fixation (Goel-Harm’s technique) are lacking. In this study, we compared the accuracy, efficiency, and safety of screw placement with the TiRobot system and biplane X-ray fluoroscopy for posterior atlantoaxial internal fixation. Consistent with a previous study [22], the proportion of “clinically acceptable” screws (graded 0 and I) was 93.2% with RA compared to 87.5% in the FH group. Out of the 100 inserted screws, ten were malpositioned (graded II and III) but did not result in severe neurovascular injury, cerebrospinal fluid leakage, or new neurologic defects.
Higher image resolution and more accurate localization with advanced imaging equipment are often accompanied by greater radiation exposure. Radiation exposure to the surgeon, patient, and operating room staff can be significant, especially in multi-segmental fusion and revision surgery, in which patients have distorted anatomy and no longer possess regular anatomic landmarks [23]. The radiation doses are 10- to 12-fold higher during spinal surgeries compared to that measured during nonspinal procedures [24]. Additionally, minimally invasive surgery (MIS) techniques cause even more radiation exposure because bony landmarks are obscured and can only be detected by fluoroscopy [25, 26]. Orthopedic surgeons who are routinely exposed to radiation have a significantly increased risk of cancer [27]. However, intraoperative electromagnetic navigation and robotic guidance system can potentially lower the dose of radiation exposure [28–30]. Schoenmayr and Kim [31] reported a 60% reduction in median radiation exposure with robot-assisted percutaneous spinal fusion surgery compared to conventional pedicle screw insertion techniques. Similarly, another single-center study showed that radiation exposure under Spine Assist guidance was 70% lower than that of conventional procedures [32]. The radiation exposure for RA surgeries in our study was also less compared to that in FH procedures. Furthermore, the average intraoperative radiation dosage of the first three cases was relatively high (
Significant blood loss and need for transfusion carry many risks including infection and coagulopathy, especially in trauma patients and in elderly patients with other comorbidities [33]. In this series, we observed a significant reduction in the amount of intraoperative blood loss when the TiRobot system was used during atlantoaxial fixation. This finding is likely explained by the optimization of surgical exposure of the C1–C2 articular complex, thereby minimizing disturbance of the robust cervical venous plexuses. In addition, the TiRobot system enables more precise intraoperative image guidance during hardware placement, thereby improving the chance of successful screw placement at one time and avoiding excessive bleeding due to the repeated adjustment of screw channels, especially in the case of C2 segment HRVA. Although EBL was relatively high and varied widely in the first few patients in the RA group (range from 100.0 to 400.0 mL), EBL decreased from
Unlike other robotic systems, TiRobot is built with an image-navigated robotic positioning platform including a robotic arm, an optical tracking system, and a surgical planning and navigation system (Figure 4(e)). The integration of robotic arm and navigation system allows seamless flow of information between planning and execution of the surgery [7]. Furthermore, the optical tracking system can detect the actual patient position and subtle postural changes in real time and coordinate with the robotic arm for real-time motion compensation, so that the arm is always accurately positioned in the preplanned screw placement trajectory. Additionally, the TiRobot system can also be used for the surgeries of long bones, femoral neck and pelvis, etc., with different hardware modules [34–37].
[figure(s) omitted; refer to PDF]
Although no serious complications were observed in our cohort, the risk of screw misplacement is substantial due to multiple causes, such as excessive pulling of the soft tissue during exposure and spinal destabilization due to extensive decompression or osteotomy. This results in a large relative displacement between the bony structures and the patient tracker. Accidental displacement of the tracker during surgery can decrease positioning accuracy or even lead to failed positioning. The robotic system must maintain good reflection and reception of infrared light. Misalignment may occur if the angle or distance exceeds the receiving range or in case of any other light interference [12]. In the case of displacement of the patient tracker, there can be gross neurovascular injury if the incorrect trajectory is followed. We also noted skidding of the drill cannula, which was attributed to skidding of the sleeve tip on the hard cortical bone surface lateral to the facet joints. Therefore, it is important for a surgeon not to rely entirely on the robot but also to use his skill and experience. When necessary, intraoperative fluoroscopy should be performed to avoid catastrophic complications. In our study, RA shortened the duration of surgery as the number of surgical cases increased, again highlighting the importance of the surgeon’s experience. Increased experience and familiarity of the operative team with the robotic system and logistics could result in a decrement of procedure length over time. A learning curve of 30 cases using RA is estimated to avoid screw malposition [30]. Similarly, Schatlo, Martinez, and Alaid suggested a minimum of 25 procedures for increasing the accuracy of robotics in spinal surgery [38]. However, the more recent generation seems to be less demanding in terms of technique [39].
5. Limitations
Our study had several inherent limitations. First, biases are common in single-center retrospective comparative studies, which affect the conclusion. Second, the sample size was comparatively small which might limit the generalizability of the findings. Third, with limited follow-up time, we can only compare the early results of the two procedures. These factors may influence our results and interpretation. Therefore, a longer follow-up, randomized case-control and multicenter study will be needed in the future.
6. Conclusion
This study demonstrated that compared to the conventional fluoroscopy-guided FH surgery, robotically assisted surgery resulted in minimal trauma, reduced bleeding and less intraoperative radiation exposure, and improved screw placement accuracy in AAD patients. The TiRobot system is still in its early developmental stage and may revolutionize spinal surgeries following improvements.
Ethical Approval
This research was approved by the ethics committee of Guangdong Provincial Hospital of Chinese Medicine and was performed according to the ethical standards outlined by the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.
Consent
This is a retrospective observational study that did not require informed consent of patients.
Authors’ Contributions
All authors have read and approved the final submitted manuscript. The following is the author contribution: Shudong Chen and Dingkun Lin did the conception and design of the research. Jiheng Zhan, Jinhao Lin, and Jiyao Luan wrote the first draft of the manuscript. Wenke Xu and Yu Hou performed data curation and formal analysis. Bolai Chen was the head surgeon of the operation and revised the manuscript. Yongjing Li and Yufeng Wang assisted the operation and prepared the photographs. Jiheng Zhan and Wenke Xu contributed equally to this work.
Glossary
Abbreviations
AAD:Atlantoaxial dislocation
RA:Robotic assistance
FH:Free-hand
VA:Vertebral artery
C1LMS:C1 lateral mass screw
C2PS:C2 pedicle screw
CT:Computed tomography
CTA:CT angiographic
MRI:Magnetic resonance imaging
MRA:Magnetic resonance angiography
EBL:Estimated blood loss
JOA:Japanese Orthopaedic Association
VAS:Visual analogue scale
BMI:Body mass index.
[1] O. P. Gautschi, M. Payer, M. V. Corniola, N. R. Smoll, K. Schaller, E. Tessitore, "Clinically relevant complications related to posterior atlanto-axial fixation in atlanto-axial instability and their management," Clinical Neurology and Neurosurgery, vol. 123, pp. 131-135, DOI: 10.1016/j.clineuro.2014.05.020, 2014.
[2] D. A. Bhowmick, E. C. Benzel, "Posterior atlantoaxial fixation with screw-rod constructs: safety, advantages, and shortcomings," World Neurosurgery, vol. 81 no. 2, pp. 288-289, DOI: 10.1016/j.wneu.2012.10.024, 2014.
[3] J. S. Yeom, J. M. Buchowski, H. J. Kim, B. S. Chang, C. K. Lee, K. D. Riew, "Risk of vertebral artery injury: comparison between C1-C2 transarticular and C2 pedicle screws," Spine Journal, vol. 13 no. 7, pp. 775-785, DOI: 10.1016/j.spinee.2013.04.005, 2013.
[4] M. Neo, T. Sakamoto, S. Fujibayashi, T. Nakamura, "The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae," Spine, vol. 30 no. 24, pp. 2800-2805, 2005.
[5] Y. Yukawa, F. Kato, K. Ito, Y. Horie, T. Hida, H. Nakashima, M. Machino, "Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope," European Spine Journal, vol. 18 no. 9, pp. 1293-1299, DOI: 10.1007/s00586-009-1032-7, 2009.
[6] J. S. Lee, D. W. Son, S. H. Lee, S. S. Ki, S. W. Lee, G. S. Song, "Comparative analysis of surgical outcomes of C1-2 fusion spine surgery between intraoperative computed tomography image based navigation-guided operation and fluoroscopy-guided operation," Journal of Korean Neurosurgical Association, vol. 63 no. 2, pp. 237-247, DOI: 10.3340/jkns.2019.0172, 2020.
[7] F. Roser, M. Tatagiba, G. Maier, "Spinal robotics: current applications and future perspectives," Neurosurgery, vol. 72, pp. 12-18, 2013.
[8] W. Tian, "Robot-assisted posterior C1-2 transarticular screw fixation for atlantoaxial instability: a case report," Spine, vol. 41 no. 19B, pp. B2-B5, DOI: 10.1097/BRS.0000000000001674, 2016.
[9] G. Vadala, S. De Salvatore, L. Ambrosio, F. Russo, R. Papalia, V. Denaro, "Robotic spine surgery and augmented reality systems: a state of the art," Neurospine, vol. 17 no. 1, pp. 88-100, DOI: 10.14245/ns.2040060.030, 2020.
[10] G. Molliqaj, B. Schatlo, A. Alaid, V. Solomiichuk, V. Rohde, K. Schaller, E. Tessitore, "Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery," Neurosurgical Focus, vol. 42 no. 5,DOI: 10.3171/2017.3.FOCUS179, 2017.
[11] J. Harms, R. P. Melcher, "Posterior C1-C2 fusion with polyaxial screw and rod fixation," Spine, vol. 26 no. 22, pp. 2467-2471, DOI: 10.1097/00007632-200111150-00014, 2001.
[12] W. Tian, Y. J. Liu, B. Liu, D. He, J. Y. Wu, X. G. Han, J. W. Zhao, M. X. Fan, Technical Committee on Medical Robot Engineering of Chinese Society of Biomedical Engineering, Technical Consulting Committee of National Robotic Orthopaedic Surgery Application Center, "Guideline for posterior atlantoaxial internal fixation assisted by orthopaedic surgical robot," Orthopaedic Surgery, vol. 11 no. 2, pp. 160-166, DOI: 10.1111/os.12454, 2019.
[13] S. D. Gertzbein, S. E. Robbins, "Accuracy of pedicular screw placement in vivo," Spine, vol. 15 no. 1, pp. 11-14, DOI: 10.1097/00007632-199001000-00004, 1990.
[14] S. Duan, H. He, S. Lv, L. Chen, "Three-dimensional CT study on the anatomy of vertebral artery at atlantoaxial and intracranial segment," Surgical and Radiologic Anatomy, vol. 32 no. 1, pp. 39-44, DOI: 10.1007/s00276-009-0552-5, 2010.
[15] J. P. Young, P. H. Young, M. J. Ackermann, P. A. Anderson, K. D. Riew, "The ponticulus posticus: implications for screw insertion into the first cervical lateral mass," Journal of Bone and Joint Surgery, vol. 87 no. 11, pp. 2495-2498, 2005.
[16] J. T. Hong, S. W. Lee, B. C. Son, J. H. Sung, S. H. Yang, I. S. Kim, C. K. Park, "Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography," Journal of Neurosurgery. Spine, vol. 8 no. 3, pp. 230-236, DOI: 10.3171/SPI/2008/8/3/230, 2008.
[17] F. Costa, A. Ortolina, L. Attuati, A. Cardia, M. Tomei, M. Riva, L. Balzarini, M. Fornari, "Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system," Journal of Neurosurgery. Spine, vol. 22 no. 2, pp. 128-133, DOI: 10.3171/2014.10.SPINE14122, 2015.
[18] C. Jacobs, P. P. Roessler, S. Scheidt, M. M. Plöger, C. Jacobs, A. C. Disch, K. D. Schaser, T. Hartwig, "When does intraoperative 3D-imaging play a role in transpedicular C2 screw placement?," Injury, vol. 48 no. 11, pp. 2522-2528, DOI: 10.1016/j.injury.2017.09.008, 2017.
[19] J. W. Hur, J. S. Kim, K. S. Ryu, M. H. Shin, "Accuracy and safety in screw placement in the high cervical spine: retrospective analysis of O-arm-based navigation-assisted C1 lateral mass and C2 pedicle screws," Clinical Spine Surgery, vol. 32 no. 4, pp. E193-E199, DOI: 10.1097/BSD.0000000000000813, 2019.
[20] A. Bertelsen, J. Melo, E. Sanchez, D. Borro, "A review of surgical robots for spinal interventions," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 9 no. 4, pp. 407-422, DOI: 10.1002/rcs.1469, 2013.
[21] W. Tian, H. Wang, Y. J. Liu, "Robot-assisted anterior odontoid screw fixation: a case report," Orthopaedic Surgery, vol. 8 no. 3, pp. 400-404, DOI: 10.1111/os.12266, 2016.
[22] X. Han, W. Tian, Y. Liu, B. Liu, D. He, Y. Sun, X. Han, M. Fan, J. Zhao, Y. Xu, Q. Zhang, "Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial," Journal of Neurosurgery. Spine, vol. 30 no. 5, pp. 615-622, DOI: 10.3171/2018.10.SPINE18487, 2019.
[23] A. S. Narain, F. Y. Hijji, K. H. Yom, K. T. Kudaravalli, B. E. Haws, K. Singh, "Radiation exposure and reduction in the operating room: perspectives and future directions in spine surgery," World Journal of Orthopedics, vol. 8 no. 7, pp. 524-530, DOI: 10.5312/wjo.v8.i7.524, 2017.
[24] B. Ravi, A. Zahrai, R. Rampersaud, "Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws," Spine, vol. 36 no. 1, pp. 84-91, DOI: 10.1097/BRS.0b013e3181cbfd09, 2011.
[25] Y. R. Rampersaud, K. T. Foley, A. C. Shen, S. Williams, M. Solomito, "Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion," Spine, vol. 25 no. 20, pp. 2637-2645, DOI: 10.1097/00007632-200010150-00016, 2000.
[26] I. H. Lieberman, M. A. Hardenbrook, J. C. Wang, R. D. Guyer, "Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system," Journal of Spinal Disorders & Techniques, vol. 25 no. 5, pp. 241-248, DOI: 10.1097/BSD.0b013e318218a5ef, 2012.
[27] G. Mastrangelo, U. Fedeli, E. Fadda, A. Giovanazzi, L. Scoizzato, B. Saia, "Increased cancer risk among surgeons in an orthopaedic hospital," Occupational Medicine (London), vol. 55 no. 6, pp. 498-500, DOI: 10.1093/occmed/kqi048, 2005.
[28] Y. Yao, X. Jiang, T. Wei, Z. Yao, B. Wu, F. Xu, C. Xiong, "A real-time 3D electromagnetic navigation system for percutaneous pedicle screw fixation in traumatic thoraco-lumbar fractures: implications for efficiency, fluoroscopic time, and accuracy compared with those of conventional fluoroscopic guidance," European Spine Journal, vol. 31 no. 1, pp. 46-55, 2022.
[29] D. Xu, S. Han, C. Wang, K. Zhu, C. Zhou, X. Ma, "The technical feasibility and preliminary results of minimally invasive endoscopic-TLIF based on electromagnetic navigation: a case series," BMC Surgery, vol. 21 no. 1,DOI: 10.1186/s12893-021-01148-9, 2021.
[30] X. Hu, I. H. Lieberman, "What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?," Clinical Orthopaedics and Related Research, vol. 472 no. 6, pp. 1839-1844, DOI: 10.1007/s11999-013-3291-1, 2014.
[31] R. Schoenmayr, I. S. Kim, "Why do I use and recommend the use of navigation?," ArgoSpine News & Journal, vol. 22 no. 4, pp. 132-135, DOI: 10.1007/s12240-010-0031-1, 2010.
[32] Y. Barzilay, J. E. Schroeder, N. Hiller, G. Singer, A. Hasharoni, O. Safran, M. Liebergall, E. Itshayek, L. Kaplan, "Robot-assisted vertebral body augmentation: a radiation reduction tool," Spine, vol. 39 no. 2, pp. 153-157, DOI: 10.1097/BRS.0000000000000100, 2014.
[33] F. L. Hitti, E. D. Hudgins, H. I. Chen, N. R. Malhotra, E. L. Zager, J. M. Schuster, "Intraoperative navigation is associated with reduced blood loss during C1-C2 posterior cervical fixation," World Neurosurgery, vol. 107, pp. 574-578, DOI: 10.1016/j.wneu.2017.08.051, 2017.
[34] H. S. Liu, S. J. Duan, S. D. Liu, F. S. Jia, L. M. Zhu, M. C. Liu, "Robot-assisted percutaneous screw placement combined with pelvic internal fixator for minimally invasive treatment of unstable pelvic ring fractures," The International Journal of Medical Robotics and Computer Assisted Surgery, vol. 14 no. 5, article e1927,DOI: 10.1002/rcs.1927, 2018.
[35] J. Y. Wu, Q. Yuan, Y. J. Liu, Y. Q. Sun, Y. Zhang, W. Tian, "Robot-assisted percutaneous transfacet screw fixation supplementing oblique lateral interbody fusion procedure: accuracy and safety evaluation of this novel minimally invasive technique," Orthopaedic Surgery, vol. 11 no. 1, pp. 25-33, DOI: 10.1111/os.12428, 2019.
[36] H. Lan, Z. Tan, K. N. Li, J. H. Gao, T. H. Liu, "Intramedullary nail fixation assisted by orthopaedic robot navigation for intertrochanteric fractures in elderly patients," Orthopaedic Surgery, vol. 11 no. 2, pp. 255-262, DOI: 10.1111/os.12447, 2019.
[37] B. Liu, F. Wu, S. Chen, X. Jiang, W. Tian, "Robot-assisted percutaneous scaphoid fracture fixation: a report of ten patients," Journal of Hand Surgery (European Volume), vol. 44 no. 7, pp. 685-691, DOI: 10.1177/1753193419848595, 2019.
[38] B. Schatlo, R. Martinez, A. Alaid, K. von Eckardstein, R. Akhavan-Sigari, A. Hahn, F. Stockhammer, V. Rohde, "Unskilled unawareness and the learning curve in robotic spine surgery," Acta Neurochirurgica, vol. 157 no. 10, pp. 1819-1823, 2015.
[39] H. J. Kim, S. H. Lee, B. S. Chang, C. K. Lee, T. O. Lim, L. P. Hoo, J. M. Yi, J. S. Yeom, "Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test," Spine, vol. 40 no. 2, pp. 87-94, 2015.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2022 Jiheng Zhan et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/
Abstract
Objective. To compare the accuracy, efficiency, and safety of robotic assistance (RA) and conventional fluoroscopy guidance for the placement of C1 lateral mass and C2 pedicle screws in posterior atlantoaxial fusion. Methods. The data of patients who underwent posterior C1–C2 screw fixation (Goel-Harm’s technique) in our hospital from August 2014 to March 2021 were retrospectively evaluated, including 14 cases under fluoroscopic guidance and 11 cases under RA. The hospital records, radiographic results, surgical data, and follow-up records were reviewed. Accuracy of screw placement was assessed using the Gertzbein and Robbins scale, and clinical outcomes were evaluated by Japanese Orthopedic Association (JOA) score, visual analogue scale (VAS), modified MacNab criteria, and postoperative complications. Results. Baseline characteristics of both groups were similar. The mean estimated blood loss in the fluoroscopic guidance and RA groups was
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details










1 Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China; Postdoctoral Workstation, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510120, China; Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China; Postdoctoral Research Station, Chinese Academy of Chinese Medical Sciences, Beijing 100700, China
2 Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China; Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China; Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China
3 Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China
4 Postdoctoral Research Station, Chinese Academy of Chinese Medical Sciences, Beijing 100700, China; Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China
5 Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China
6 Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China; Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China