It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
The adverse impact of adjacent contours on letter visual acuity is known as crowding but there is conflicting evidence that foveal crowding may be reduced or disappears under low contrast conditions. Potential differences in foveal crowding with contrast on clinical measurements of visual acuity, including test–retest repeatability, were assessed. Visual acuity was measured at the fovea on adult participants with normal vision under three different contrast levels (− 90, − 10 and − 5%). Three rows of 5 letters, each row differing in size by 0.05 logarithm of the minimum angle of resolution (logMAR) from largest to smallest were displayed at the center of a monitor. Crowding was varied by varying the separation between horizontally adjacent letters from 100% optotype size to 50%, 20% and 10% optotype size. Inter-row spacing was proportional to optotype size. Observers read the letters on the middle row only. Measurements continued by reducing the size of the letters until 3 or more errors were made and were repeated on two separate days. Visual acuity worsened as both letter contrast decreased and inter-optotype separation reduced (expressed as a percentage of letter width). When expressed in minutes of arc of separation the impact of crowding was the same across all contrasts. Crowding occurs for both high and low contrast charts and should be considered when assessing low contrast visual acuity. Test–retest repeatability showed little or no dependence on either contrast or inter-optotype separation.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details


1 Palacký University Olomouc, Department of Optics, Olomouc, Czech Republic (GRID:grid.10979.36) (ISNI:0000 0001 1245 3953)
2 University of Huddersfield, Centre for Vision Across the Life Span, Department of Optometry and Vision Sciences, Huddersfield, UK (GRID:grid.15751.37) (ISNI:0000 0001 0719 6059)