Abstract

Background

To confirm the performance of the first hemispherical positron emission tomography (PET) for the brain (Vrain) that we developed to visualise the small nuclei in the deep brain area, we compared 18F-fluorodeoxyglucose (FDG) brain images with whole-body PET images.

Methods

Ten healthy male volunteers (aged 22–45 years) underwent a representative clinical whole-body PET, followed by Vrain each for 10 min. These two scans were initiated 30 min and 45 min after FDG injection (4.1 ± 0.5 MBq/kg), respectively. First, we visually identified the small nuclei and then compared their standardised uptake values (SUVs) with the participants’ age. Next, the SUVs of each brain region, which were determined by applying a volume-of-interest template for anatomically normalised PET images, were compared between the brain images with the Vrain and those with the whole-body PET images.

Results

Small nuclei, such as the inferior colliculus, red nucleus, and substantia nigra, were more clearly visualised in Vrain than in whole-body PET. The anterior nucleus and dorsomedial nucleus in the thalamus and raphe nucleus in the brainstem were identified in Vrain but not in whole-body PET. The SUVs of the inferior colliculus and dentate gyrus in the cerebellum positively correlated with age (Spearman’s correlation coefficient r = 0.811, p = 0.004; r = 0.738, p = 0.015, respectively). The SUVs of Vrain were slightly higher in the mesial temporal and medial parietal lobes than those in whole-body PET.

Conclusions

This was the first time that the raphe nuclei, anterior nuclei, and dorsomedial nuclei were successfully visualised using the first hemispherical brain PET.

Trial registration 

Japan Registry of Clinical Trials, jRCTs032210086, Registered 13 May 2021, https://jrct.niph.go.jp/latest-detail/jRCTs032210086.

Details

Title
Small nuclei identification with a hemispherical brain PET
Author
Takahashi, Miwako 1   VIAFID ORCID Logo  ; Akamatsu, Go 1 ; Iwao, Yuma 1 ; Tashima, Hideaki 1 ; Yoshida, Eiji 1 ; Yamaya, Taiga 1 

 National Institutes for Quantum Science and Technology (QST), Department of Advanced Nuclear Medicine Sciences, Institute for Quantum Medical Science, Chiba, Japan (GRID:grid.482503.8) (ISNI:0000 0004 5900 003X) 
Publication year
2022
Publication date
Dec 2022
Publisher
Springer Nature B.V.
e-ISSN
21977364
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2722750647
Copyright
© The Author(s) 2022. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.