Introduction
Mosquito-borne diseases such as malaria, filariasis and dengue fever have placed a huge burden on human populations worldwide [1–3]. Aedes albopictus is a major vector of the viruses that cause dengue fever and Zika virus infections [4]. Culex quinquefasciatus is the primary vector for the viral and filarial pathogens that cause Saint Louis encephalitis, West Nile fever, Rift Valley fever and lymphatic filariasis [5–8]. Aedes albopictus and Cx. quinquefasciatus are the predominant mosquito species in urban China [9, 10]. At present, integrated mosquito management is the main strategy for prevention and control of vector mosquitoes and the pathogens they transmit [11].
Monitoring the density of vector mosquitoes is important for predicting possible epidemics of mosquito-borne infectious diseases and evaluating vector control. At present, the methods for monitoring adult mosquito densities are light traps, human-baited double-net traps, BioGents Sentinel (BGS) traps and human landing catches (HLCs) [12–14]. However, light traps for monitoring Ae. albopictus have limited efficacy because they are principally active diurnally [14, 15]. Traditional HLC methods may not meet ethical requirements and have potential health risks for collectors during an epidemic. Human-baited, double-net trap are an alternative to HLCs for collecting outdoor vector mosquitoes but they are labor-intensive and time-consuming [13].
BGS traps have been used widely and are reported to be effective when applied to monitoring and estimating vector mosquito densities [16–19]. However, these traps still require manual support to count and identify the captured mosquitoes and may not reflect mosquito densities in a timely manner. Recently, a new device from BioGents, named the BG-Counter, was developed to count automatically captured mosquitoes and transfer the data remotely to the surveillance team. However, the reported sensitivity and specificity of the BG-Counter was shown to vary greatly in a study comprising five North Carolina counties with mean daily accuracies ranging from 9.4% to 80.1% [20]. Therefore, although the BG-Counter may be a useful alternative in some circumstances, the accuracy will need to be improved before is should be widely adopted.
We designed a next-generation trap, MS-300, for Ae. albopictus and Cx. quinquefasciatus that contains an infrared window and automatic counting device to sensitively detect mosquito entry and automatically transmit the data to cloud-based server and remote terminals. An environmental sensor in MS-300 can monitor the relationships among mosquito densities and daily and seasonal factors. The efficiencies of the device for capturing Ae. albopictus and Cx. quinquefasciatus were evaluated in a mosquito net cage, wire-gauze screened house and in the field, and analyzed in comparison with data from BGS trap and HLCs.
Material and methods
Ethics statement
No specific permits were required for the described field studies. These studies did not involve endangered or protected species. Collectors provided written consent to participate in the human landing catches.
Mosquitoes
Established laboratory colonies of Ae. albopictus and Cx. quinquefasciatus collected from Foshan (in 1981) and Guangzhou (in 1993), Guangdong Province, China, were provided by the Guangdong Provincial Center for Disease Control and Prevention. Larvae (120–200 larvae/L water) were reared in stainless-steel trays containing dechlorinated water and were fed yeast and turtle food. All mosquito stages were reared in an insectary maintained at 27±1°C, 70%–80% relative humidity and a 16-h light/8-h dark photoperiod, and adults offered a 10% sucrose solution ad libitum.
Mosquito size measurements
After anesthesia with ice, the linear lengths of each of 50 5–7 day-old adult male and female Ae. albopictus and Cx. quinquefasciatus were measured using stereomicroscopy from a lateral view (S1 Fig). The average lengths from the top of the head to the tip of the genitalia were recorded as a size reference for designing the infrared grates to identify the passing objects.
Setting the infrared detection window
The average lengths of the target mosquitoes were recorded as a reference for designing the X- and Y-dimensions of the infrared grates. When the objects passed through the infrared detection window, the projection lines in X and Y dimensions would be blocked. If the size of the passing object matches with the reference, the data would be recognized and recorded as one of the target mosquitoes. Because environmental illumination may affect the emission and reception of infrared, the standard for the infrared grates needs to be adjusted accordingly to the light conditions of the study sites. The passage time of the object through the detection window is varied based on the size and flying speed of target mosquito and the speed of the fan in the MS-300 monitor, so that the infrared scanning intervals were set accordingly to such specific data. When an object was trapped by the MS-300, the passing data are recorded and analyzed to determine whether or not the object is a mosquito.
Assembling the MS-300 monitor
The MS-300 device comprises components that include a mosquito detection platform, data processing hardware, collection bag, fan and lure. The mosquito lure, Mix-5, is a proprietary reagent and efficiently attracts Ae. albopictus and Cx. quinquefasciatus [21]. The environmental sensor records the temperature and illumination of the study site every 30 minutes.
MS-300 monitoring system
The MS-300 monitoring system is supported by a web-based database for storage of mosquito counts, geospatial and environmental data (temperature and illumination). The data are transferred to an internet web page that can be accessed via PC, smartphone or tablet. Using a 4G wireless communication network and the web application, investigators can manage the MS-300 monitor and collect data on mosquito population dynamics, daily activity patterns and environmental factors.
Laboratory tests
The MS-300 was placed in a cage constructed of mosquito netting (3 × 2 ×2m). A total of 100 female Ae. albopictus or Cx. quinquefasciatus 5–7 days post-emergence were released into the cage. The mosquitoes captured in the mosquito bag server were counted after 24 hours and compared with the data sent to the cloud-based server. The experiment was repeated six times. Efficiency and accuracy were calculated as follows:
Eq 1: Efficiency = number of mosquitoes in bag/number of mosquitoes released.
Eq 2: Accuracy = number of mosquitoes in bag/cloud-based server data.
When the number of mosquitoes in the bag was more than that reported in the cloud-based server data, an absolute value in the following formula was used:
Eq 3: Correction formula of accuracy = 1-∣[1-(number of mosquitoes in bag/cloud-based server data)]∣*100.
Semi-field tests
Two MS-300 monitors, one with and one without lure, were placed parallel in the wire-gauze screened house (4 × 3 × 2.1m). One hundred female Ae. albopictus or Cx. quinquefasciatus were released into the house. The mosquitoes trapped in the MS-300 bag as well as the numbers sent to the cloud-based server data were counted 24 hours later. The experiment was repeated six times. Efficiency and accuracy were calculated using the formulae described above.
Field tests
One MS-300 monitor and one BGS trap were placed (5 meters apart) in a garden (outdoor) or a residence (indoor). The Mix-5 lures were used in the absence of CO2. The insects trapped into the collection bag as well as the cloud-based server data were counted every 24 hours. The experiment was conducted for 98 days (From May 1, 2021 to August 14, 2021). HLCs were conducted at 17:30–18:30 every seven days based on the standard manual [22]. The formulas were calculated as follows:
Eq 1: Accuracy = number of mosquitoes in bag/cloud-based server data.
Eq 2: Specificity = number of mosquitoes in bag/number of insects in bag.
Eq 3: HLCs = number of mosquitoes collected/(person*hour).
Statistical analyses
All statistical analyses were performed using SPSS version 20.0 (IBM, Chicago, IL, USA). The efficiency, accuracy and specificity of the devices were compared using independent samples t-tests or nonparametric tests. The number of mosquitoes in the MS-300 monitor and BGS traps were compared using a nonparametric test. Pearson correlation coefficient, r, was used to determine the strength and direction of a linear relationship, between two variables [23, 24]. The correlation between the MS-300 monitor and temperature were determined by Pearson’s correlation analysis test. Pearson’s correlation analysis test also was used to determine if there was an association among MS-300 monitors, BGS traps and HLCs. P-values > 0.05 were considered not significant.
Results
Sizes of adult male and female Ae. albopictus and Cx. quinquefasciatus
Fifty male and female mosquitoes each were measured using stereomicroscopy (S1 Fig). The average lengths of Ae. albopictus were 4.75 ± 0.27mm for the females and 3.99 ± 0.11mm for the males, and those of Cx. quinquefasciatus were 4.83 ± 0.30mm for the females and 4.62 ± 0.30mm for the males (S1 Table).
Development of the specific and real-time monitor for Ae. albopictus and Cx. quinquefasciatus
The MS-300 monitor includes the infrared probes and automatic counting devices (Fig 1). The X- and Y-dimension infrared grates were set based on the sizes of Ae. albopictus and Cx. quinquefasciatus (S1 Table).
[Figure omitted. See PDF.]
Fig 1. Schematic diagram of the detection and data transmission modules of MS-300.
The MS-300 monitor contains an infrared detection window and automatic counting device. An environmental sensor monitors and records the environmental factors such as temperature and illumination. Data processing hardware and software in the monitor perform an analysis and real-time data are transmitted automatically to cloud-based server services and remote terminals.
https://doi.org/10.1371/journal.pntd.0010701.g001
The MS-300 monitor combines components that include a mosquito detection platform, data processing hardware and software, a collection bag, fan and the Mix-5 lure (Fig 2A). The gelatinous lure is a patented attractant and is efficient for attracting Ae. albopictus and Cx. quinquefasciatus, therefore the MS-300 monitor does not require the use of large CO2 canisters for attraction. When the device is running, airflow will volatilize the Mix-5. The mosquitoes are attracted by Mix-5 and suctioned by a fan into the monitor. The objects passing through the detection device are differentiated from other insects or dust particles as mosquitoes and recorded. The mosquito data are transferred automatically to a cloud-based server at 30-min intervals and accessed via a PC, smartphone or tablet in real-time. Furthermore, local environmental factors such as temperature and illumination can be sampled and analyzed with the mosquito density in real-time.
[Figure omitted. See PDF.]
Fig 2. Test of MS-300 monitor in different settings.
(A) Left: Photograph of the MS-300 monitor; Right: Schematic diagram of MS-300 monitor. (B) Test of MS-300 monitor in laboratory. Left: actual laboratory scene; Right: efficiency and accuracy verification of the MS-300 monitor in capturing mosquitoes; the error bars represent 95% confidence intervals (CIs). (C) Test of MS-300 monitor in semi-field. Left: actual semi-field scene; Center: efficiency and accuracy verification of the MS-300 monitor in capturing mosquitoes; Right: hourly mosquito capture numbers over 24 hours; the error bars represent 95% CIs; ***, P < 0.001. (D) Test of the MS-300 monitor in field. Left: actual field scene; Center: specificity of the MS-300 monitor in catching Ae. albopictus and Cx. quinquefasciatus in two sites; Right: weekly variations in the densities of Ae. albopictus and Cx. quinquefasciatus and local temperatures in study sites; the error bars represent 95% CIs.
https://doi.org/10.1371/journal.pntd.0010701.g002
Test of MS-300 monitor in the laboratory
One hundred female Ae. albopictus or Cx. quinquefasciatus were released into the mosquito net cage and the numbers of mosquitoes in the MS-300 collection bag and reported to the cloud-based server were counted 24h later (Fig 2B, left). The efficiency and accuracy of the MS-300 monitor in catching and identifying Ae. albopictus were 98.5% and 99.3%, respectively, and 95.8% and 98.6% in catching Cx. quinquefasciatus (Fig 2B, right). An average of 98.5±1.5 Ae. albopictus were captured by MS-300 and 99.2±1.2 were recorded in the cloud-based server, while 95.8±2.6 and 97.2±2.4, respectively, were recorded for Cx. quinquefasciatus (S2 Table). No significant differences are detected in efficiency and identification between the Ae. albopictus and Cx. quinquefasciatus captured by the MS-300 monitor and this supports the conclusion that the monitor can accurately identify and record these two species.
Test of the MS-300 monitor in semi-field
Two MS-300 monitors, one with lure (treatment) and one without (control), were placed in parallel in a wire-gauze screen house (4m × 2m × 2.1m) (Fig 2C, left). One hundred female Ae. albopictus or Cx. quinquefasciatus were released into the enclosure and the numbers of mosquitoes in the MS-300 collection bag and in cloud-based server were counted 24h later. The efficiencies of the treatment in catching Ae. albopictus and Cx. quinquefasciatus were 54.2% and 51.3%, respectively, which are significantly higher than 4% and 4.2% of the control (t = 9.51, p<0.001; t = 12.314, p<0.001) (Fig 2C, center), indicating that Mix-5 was effective in attracting Ae. albopictus and Cx. quinquefasciatus. No significant differences in the accuracy of the MS-300 monitor were found with Ae. albopictus and Cx. quinquefasciatus (96.3% and 95.1%, respectively, S3 Table), and this supports the conclusion that the monitor can accurately identify and record Ae. albopictus and Cx. quinquefasciatus. An average of 41.8±12.9 Ae. albopictus and 44.5±10 Cx. quinquefasciatus were uncaptured, which included dead mosquitoes on the floor of the structure (S3 Table).
The numbers of Ae. albopictus and Cx. quinquefasciatus captured in the MS-300 monitor and recorded in the cloud-based server and illumination at one-hour intervals for a total of 24 hours also were recorded (Fig 2C, right and S3 Table). The time span of illumination was 7:00–19:00 with peak illuminance (1673 lux) at 11:00. The illuminance gradually decreased and dropped to 0 at 20:00. The first captured peak in Ae. albopictus showed a slow increase and then remain stable (8:00–10:00), while the second peak showed a rapid increase with an obvious pattern (17:00–19:00). An average of 4±0.6 (maximum) Ae. albopictus were captured at 09:00 (1011 lux) in the first active period, while 9.2±2.9 (maximum) were recorded at 18:00 (278 lux) in the second active period. Only one active period (19:00–24:00) was recorded in Cx. quinquefasciatus with an average of 8.5±1.6 (maximum) at 21:00 (0 lux). These results support the conclusion that MS-300 monitor can accurately monitor the daily activity Ae. albopictus and Cx. quinquefasciatus (Fig 2C, right).
Test of MS-300 monitor in the field
Field tests of MS-300 monitor were conducted from May 1 to August 14, 2021, in a garden and a residence using BGS traps as controls (Fig 2D, left). A total of 940 and 3605 Ae. albopictus (z = -2.115, p<0.05) and 1774 and 6200 Cx. quinquefasciatus (z = -3.768, p<0.001) were trapped in the garden by MS-300 and BGS, respectively (Table 1). One-hundred, seventy-eight (178) and 2049 Ae. albopictus (z = -4.319, p<0.001) and 528 and 4553 Cx. quinquefasciatus (z = -4.069, p<0.001) were recovered in the residence by MS-300 and BGS, respectively (Table 1). These data show that the efficiency of MS-300 is significantly lower than that of BGS. However, the average specificities of MS-300 and BGS were 88.9% and 86.9%, respectively, in the garden and 71.9% and 76.8% in the residence with no significant difference between them (Table 1). In the garden, a total of 467 nontarget arthropods, accounting for 11.1% of the total insects caught, collected by MS-300 during that period, included Diptera (Drosophila melanogaster and Chironomus kiiensis), Hymenoptera and Coleoptera. In the residence, we collected 269 nontarget arthropods, accounting for 28.1% of the total insects caught by MS-300, and these were mostly species in the orders Diptera (Drosophila melanogaster, Chironomus kiiensis and Chrysomya megacephala), Hymenoptera, Araneae and Coleoptera (Table 1). Furthermore, no significant difference was found in the specificity of Ae. albopictus (26.1% and 23.7%) and Cx. quinquefasciatus (62.7% and 48.2%) of MS-300 monitor in the garden and residence (Fig 2D, center), and no significant differences were found in the mean accuracy (79.4% and 64.9%) of the MS-300 monitor in two field sites (Table 1).
[Figure omitted. See PDF.]
Table 1. Test of three monitoring methods on Ae. albopictus and Cx. quinquefasciatus in the field.
https://doi.org/10.1371/journal.pntd.0010701.t001
The number of Ae. albopictus captured in the garden by the MS-300 monitor showed a positive correlation with the local temperature (r = 0.891, p<0.01), but that was negatively-correlated for Cx. quinquefasciatus (r = -0.655, p<0.05) (Fig 2D, right-Garden). The number of Ae. albopictus captured in the residence by the MS-300 monitor also showed a positive correlation with the local temperature (r = 0.769, p<0.01), but again was negatively-correlated for Cx. quinquefasciatus (r = -0.297, p>0.05), although insignificant for the latter (Fig 2D, right-Residence). While the density of mosquitoes is correlated with many factors such as temperature, humidity and rainfall, these results show that the MS-300 device could monitor the density of Ae. albopictus and Cx. quinquefasciatus in the field and correlate mosquito abundance with temperature.
In addition to comparing the efficiency of the MS-300 monitor and BGS traps, HLCs were conducted every week in two study sites (Fig 3). The number of Ae. albopictus captured by HLCs in the garden were correlated significantly between the MS-300 monitor (r = 0.836, p<0.01) and BGS trap (r = 0.808, p<0.01). The number of Ae. albopictus trapped in the MS-300 monitor was correlated strongly to that in BGS trap (r = 0.985, p<0.01) (Fig 3A). For Cx. quinquefasciatus, the number captured by the MS-300 monitor also was correlated to that of the BGS traps (r = 0.814, p<0.01) (Fig 3B). The number of Ae. albopictus captured by HLCs in the residence was correlated significantly with the MS-300 monitor (r = 0.894, p<0.01) and BGS trap (r = 0.777, p<0.01). Furthermore, the number of Ae. albopictus in the MS-300 monitor was correlated strongly to that in the BGS trap (r = 0.899, p<0.01) (Fig 3A). The number of Cx. quinquefasciatus captured by the MS-300 monitor correlates with that in the BGS trap (r = 0.898, p<0.01) (Fig 3B). The statistical analysis showed a significant positive relationship among the MS-300 monitor, BGS trap and HLCs, which supports the conclusion that the MS-300 device could monitor Ae. albopictus and Cx. quinquefasciatus as well as HLCs and BGS trap.
[Figure omitted. See PDF.]
Fig 3. Comparisons among MS-300, BGS traps and human landing catches on the capture of Ae. albopictus and Cx. quinquefasciatus.
(A) Ae. albopictus. A1: The number of Ae. albopictus captured by the MS-300 monitor at two field sites; A2: The number of Ae. albopictus captured by BGS traps at two field sites; A3: The number of Ae. albopictus captured by human landing catches at two field sites. (B) Cx. quinquefasciatus. B1: The number of Cx. quinquefasciatus captured by the MS-300 monitor at two field sites; B2: The number of Cx. quinquefasciatus captured by BGS trap at two field sites.
https://doi.org/10.1371/journal.pntd.0010701.g003
Discussion
The laboratory and semi-field tests indicate that the MS-300 monitor is a reliable and efficient trap for Ae. albopictus and Cx. quinquefasciatus. Although it is a limitation that both species were not tested against each other, and the efficiencies of the MS-300 monitor in catching Ae. albopictus and Cx. quinquefasciatus in laboratory tests (98.5% and 95.8%) were higher than that in semi-field test (54.2% and 51.3%), no significant differences were found in the accuracy in the laboratory test (99.3% and 98.6%) and semi-field test (96.3% and 95.1%), which indicates that the captured mosquitoes in MS-300 are consistent with the data documented in cloud-based server. In the semi-field test, more than half of the mosquitoes were captured in the MS-300 with a lure but less than 5% in the MS-300 without a lure, which indicates that the MS-300 monitor with the Mix-5 lure can efficiently attract Ae. albopictus and Cx. quinquefasciatus.
With the real-time data from the semi-field tests, we can see that Ae. albopictus displayed distinct bimodal activity with a morning (8:00–10:00) and dusk peak (17:00–19:00), while only one activity peak (20:00–24:00) was observed for Cx. quinquefasciatus. These findings clarify the circadian behavior of Ae. albopictus and Cx. quinquefasciatus that might be used for guiding the mosquito control.
The field tests showed that the captured mosquito species are mainly Ae. albopictus and Cx. quinquefasciatus, which is consistent with previous reports [25, 26]. The numbers of Ae. albopictus and Cx. quinquefasciatus captured by the BGS traps were significantly higher than those of the MS-300 monitor, although both used the same Mix-5 lure. Possible reasons for the difference may be due to the appearance of BGS trap, which is more visually attractive to mosquitoes than the MS-300, and the air flowing in BGS traps may be more efficient in capturing mosquitoes than the MS-300 [17, 27], and these factors would be improved for a next-generation MS-300. However, there is no significant difference between the MS-300 monitor and BGS trap in the mean specificity in two field sites. The high accuracy capability of the MS-300 monitor shows that this internet-based device can accurately identify and record Ae. albopictus and Cx. quinquefasciatus.
Previous research has evaluated the effectiveness of the BG-Counter, a new internet-based device from BioGents [20, 28–32]. However, the effectiveness of BG-Counter varied greatly. Day et al assessed the BG-Counter in five North Carolina counties and the mean daily accuracy ranged from 9.4% to 80.1% [20]. One explanation for such low accuracy in the BG-Counter may be its one-way infrared LEDS and light detectors, which might not accurately discriminate objects passing through the detection window. The X- and Y-dimension infrared lights-detectors and lighting frequency design in MS-300 may increase the ability to discriminate the passing object and to identify the mosquitoes accurately. It may be verified in the further research of comparing the effectiveness and accuracy of the BG-Counter and the MS-300 monitor.
Temperature is the most important abiotic factor affecting development and survivorship of mosquitoes [33]. In the field tests, the number of Ae. albopictus captured by the MS-300 monitor showed a significant positive correlation with temperature at the two study sites. This supports the conclusion that the MS-300 monitor can be used to survey seasonal fluctuations of Ae. albopictus abundance indexed with the prevailing temperatures. The number of Cx. quinquefasciatus captured by the MS-300 monitor in the garden setting showed a significant negative correlation with temperature while the number was not significant in the residence. Seasonal variations in temperature and population density of these two vector mosquitoes recorded in real-time by the MS-300 monitor can serve as guide for mosquito control strategies under the differing conditions.
The success of MS-300 monitor was compared with human landing catches, the gold-standard method for monitoring mosquito density. The numbers of Ae. albopictus captured by the MS-300 monitor and BGS traps were correlated significantly with HLCs in both garden and residence trials. Meanwhile, the numbers of Cx. quinquefasciatus captured by the MS-300 monitor was correlated positively to those recovered in the BGS traps. HLCs were not considered in evaluating Cx. quinquefasciatus because HLCs were conducted from 17:30–18:30, which is not the period of peak activity for Cx. quinquefasciatus. Although the numbers of Ae. albopictus and Cx. quinquefasciatus captured by the BGS traps were higher than those of the MS-300 monitor, the high accuracy capability of the MS-300 monitor and positive correlation amongst these three monitoring methods means that the MS-300 monitor can inform users interested in monitoring circadian activity trends or determining the effectiveness of adult mosquito control efforts in an early warning manner.
Conclusions
Our results demonstrate that the MS-300 monitor can be a dependable tool for assessing Ae. albopictus and Cx. quinquefasciatus population densities and circadian activity patterns in both laboratory and field surveys. It can be a powerful tool to guide prevention and control efforts of mosquito-borne diseases when applied to daily and seasonal population fluctuations and a potential surveillance tool for other mosquito species in other locations.
Supporting information
S1 Fig. Measurement of lengths of adult male and female Aedes albopictus and Culex quinquefasciatus.
https://doi.org/10.1371/journal.pntd.0010701.s001
(PDF)
S1 Table. Average lengths of adult male and female Aedes albopictus and Culex quinquefasciatus.
https://doi.org/10.1371/journal.pntd.0010701.s002
(XLSX)
S2 Table. Test of MS-300 monitor in laboratory.
*Efficiency = number of mosquitoes in bag/number of mosquitoes released. †Accuracy = number of mosquitoes in bag/cloud-based server data.
https://doi.org/10.1371/journal.pntd.0010701.s003
(XLS)
S3 Table. Test of MS-300 monitor in semi-field trail.
*Efficiency = number of mosquitoes in bag/number of mosquitoes released. †Accuracy = number of mosquitoes in bag/cloud-based server data. ‡Correction formula of accuracy = 1-∣[1-(Number of mosquitoes in bag/cloud-based server data)]∣*100.
https://doi.org/10.1371/journal.pntd.0010701.s004
(XLS)
Acknowledgments
AAJ is a Donald Ben Professor at the University of California Irvine.
Citation: Lai Z, Wu J, Xiao X, Xie L, Liu T, Zhou J, et al. (2022) Development and evaluation of an efficient and real-time monitoring system for the vector mosquitoes, Aedes albopictus and Culex quinquefasciatus. PLoS Negl Trop Dis 16(9): e0010701. https://doi.org/10.1371/journal.pntd.0010701
1. Shuman E K. Global climate change and infectious diseases. Int J Occup Env Med. 2011;2(1):11–9. pmid:23022814
2. Ranson H, Burhani J, Lumjuan N, Black IV. Insecticide resistance in dengue vectors. TropIKA. net, 2010, 1(1). Available from: https://archive.lstmed.ac.uk/999/
3. World Health Organization. Global strategy for dengue prevention and control 2012–2020. 2012. Available from: https://apps.who.int/iris/bitstream/handle/10665/75303/9789241504034_eng.pdf
4. Bde Almeida JP, Aguiar ER, Armache JN, Olmo RP, Marques JT. The virome of vector mosquitoes. Curr Opin Virol. 2021;49:7–12. pmid:33991759
5. Rutledge CR, Day JF, Lord CC, Stark LM, Tabachnick WJ. West Nile virus infection rates in Culex nigripalpus (Diptera: Culicidae) do not reflect transmission rates in Florida. J Med Entomol. 2003;40(3):253–258. pmid:12943101
6. Hribar LJ, Vlach JJ, Demay DJ, Stark LM, Stoner RL, Godsey MS, et al. Mosquitoes infected with West Nile virus in the Florida Keys, Monroe County, Florida, USA. J Med Entomol. 2003;40(3):361–363. pmid:12943117
7. Vitek CJ, Richards SL, Mores CN, Day JF, Lord CC. Arbovirus transmission by Culex nigripalpus in Florida, 2005. J Med Entomol. 2008;45(3):483–493. pmid:18533444
8. Fontes G, Leite AB, de Lima AR, Freitas H, Ehrenberg JP, da Rocha EM. Lymphatic filariasis in Brazil: epidemiological situation and outlook for elimination. Parasit Vectors. 2012;5:272. pmid:23181663
9. Wu F, Liu Q, Lu L, Wang J, Song X, Ren D. Distribution of Aedes albopictus (Diptera: Culicidae) in northwestern China. Vector Borne Zoonotic Dis. 2011;11(8):1181–1186. pmid:21254912
10. Zhao M, Dong Y, Ran X, Guo X, Xing D, Zhang Y, et al. Sodium channel point mutations associated with pyrethroid resistance in Chinese strains of Culex pipiens quinquefasciatus (Diptera: Culicidae). Parasit Vectors. 2014;7:369. pmid:25128988
11. Gubler DJ. Dengue and dengue hemorrhagic fever. Clin Microbiol Rev. 1998;11(3):480–496. pmid:9665979
12. Govella NJ, Chaki PP, Mpangile JM, Killeen GF. Monitoring mosquitoes in urban Dar es Salaam: evaluation of resting boxes, window exit traps, CDC light traps, Ifakara tent traps and human landing catches. Parasit Vectors. 2011;4:40. pmid:21418622
13. Tangena JA, Thammavong P, Hiscox A, Lindsay SW, Brey PT. The Human-Baited Double Net Trap: An Alternative to Human Landing Catches for Collecting Outdoor Biting Mosquitoes in Lao PDR. PLoS One. 2015;10(9):e0138735. pmid:26381896
14. Li Y, Su X, Zhou G, Zhang H, Puthiyakunnon S, Shuai S, et al. Comparative evaluation of the efficiency of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap for the surveillance of vector mosquitoes. Parasit Vectors. 2016;9(1):446. pmid:27519419
15. Lines JD, Curtis CF, Wilkes TJ, Njunwa KJ. Monitoring human-biting mosquitoes (Diptera: Culicidae) in Tanzania with light-traps hung beside mosquito nets. B Entomol Res, 1991, 81(1): 77–84.
16. Arimoto H, Harwood JF, Nunn PJ, Richardson AG, Gordon S, Obenauer PJ. Comparison of Trapping Performance Between the Original BG-Sentinel Trap and BG-Sentinel 2 Trap (1). J Am Mosq Control Assoc. 2015;31(4):384–387. pmid:26675464
17. Guindo A, Epopa PS, Doumbia S, Millogo AA, Diallo B, Yao FA, et al. Improved BioGents Sentinel trap with heat (BGSH) for outdoor collections of Anopheline species in Burkina Faso and Mali, West Africa. Parasit Vectors. 2021;14(1):82. pmid:33509273
18. Pombi M, Guelbeogo WM, Calzetta M, Sagnon NF, Petrarca V, Gioia VL, et al. Evaluation of a protocol for remote identification of mosquito vector species reveals BG-Sentinel trap as an efficient tool for Anopheles gambiae outdoor collection in Burkina Faso. Malar J. 2015;14:161. pmid:25888896
19. Gama RA, Silva IM, Geier M, Eiras AE. Development of the BG-Malaria trap as an alternative to human-landing catches for the capture of Anopheles darlingi. Mem Inst Oswaldo Cruz. 2013;108(6):763–771. pmid:24037199
20. Day CA, Richards SL, Reiskind MH, Doyle MS, Byrd BD. Context-Dependent Accuracy of the BG-Counter Remote Mosquito Surveillance Device in North Carolina. J Am Mosq Control Assoc. 2020;36(2):74–80. pmid:33647123
21. Xie L, Yang W, Liu H, Liu T, Xie Y, Lin F, et al. Enhancing attraction of the vector mosquito Aedes albopictus by using a novel synthetic odorant blend. Parasit Vectors. 2019;12(1):382. pmid:31362759
22. Gimnig JE, Walker ED, Otieno P, Kosgei J, Olang G, Ombok M, et al. Incidence of malaria among mosquito collectors conducting human landing catches in western Kenya. Am J Trop Med Hyg. 2013;88(2):301–308. pmid:23249685
23. Schober P, Boer C, Schwarte LA. Correlation Coefficients: Appropriate Use and Interpretation. Anesth Analg. 2018;126(5):1763–1768. pmid:29481436
24. Taylor R. Interpretation of the correlation coefficient: a basic review. J Diagn Med Sonog, 1990, 6(1): 35–39.
25. Zou HB, Song W, Lin HB, Li JL, Wang YF, Li ZQ, et al. Background investigation on mosquitoes at Guangzhou ports along the Zhujiang river. Chinese J Frontier Health Quarantine. 2014;37(05):331–5.
26. Liu YS, Liang HY, Huang F, Li GH, Zhai JS, Zhang WD, et al. Investigation on Mosquitoes at Luogang Ports in Guangzhou from 2008 to 2009. Chinese J Frontier Health Quarantine. 2010;33:4.
27. Williams CR, Long SA, Russell RC, Ritchie SA. Field efficacy of the BG-Sentinel compared with CDC Backpack Aspirators and CO2-baited EVS traps for collection of adult Aedes aegypti in Cairns, Queensland, Australia. J Am Mosq Control Assoc, 2006, 22(2): 296–300. pmid:17019776
28. Clifton ME, Xamplas CP, Nasci RS, Harbison J. Gravid Culex pipiens Exhibit A Reduced Susceptibility to Ultra-Low Volume Adult Control Treatments Under Field Conditions. J Am Mosq Control Assoc. 2019;35(4):267–278. pmid:31922942
29. Lucas KJ, Watkins A, Phillips N, Appazato DJ, Linn P. The Impact of Hurricane Irma on Population Density of the Black Salt-Marsh Mosquito, Aedes taeniorhynchus, in Collier County, Florida. J Am Mosq Control Assoc. 2019;35(1):71–74. pmid:31442180
30. Johnson BJ, Manby R, Devine GJ. Further Evidence that Development and Buffer Zones Do Little To Reduce Mosquito Nuisance from Neighboring Habitat. J Am Mosq Control Assoc. 2020;36(3):204–207. pmid:33600590
31. Johnson B J, Manby R, Devine G J. What happens on islands, doesn’t stay on islands: Patterns of synchronicity in mosquito nuisance and host-seeking activity between a mangrove island and adjacent coastal development. Urban Ecosyst, 2020, 23(6): 1321–1333.
32. Pruszynski C. The BG-Counter: A new surveillance trap that remotely measures mosquito density in real-time. Wing Beats, 2016, 27(1).
33. Asigau S, Parker PG. The influence of ecological factors on mosquito abundance and occurrence in Galápagos. J Vector Ecol. 2018;43(1):125–137. pmid:29757523
About the Authors:
Zetian Lai
Contributed equally to this work with: Zetian Lai, Jing Wu
Roles Conceptualization, Formal analysis, Methodology, Validation, Visualization, Writing – original draft, Writing – review & editing
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Jing Wu
Contributed equally to this work with: Zetian Lai, Jing Wu
Roles Data curation, Formal analysis, Investigation, Methodology, Validation
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Xiaolin Xiao
Roles Data curation, Investigation, Methodology
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Lihua Xie
Roles Data curation, Formal analysis, Methodology
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Tong Liu
Roles Data curation, Formal analysis, Methodology
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Jingni Zhou
Roles Methodology, Visualization
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Ye Xu
Roles Methodology, Validation
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Yiquan Cai
Roles Methodology, Visualization
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Feng Lin
Roles Methodology, Visualization
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
Bin Li
Roles Formal analysis, Software
Affiliation: Guangzhou NewVision Electronic and Technology Co. Ltd, Guangzhou, China
Lu Gan
Roles Methodology, Visualization
Affiliation: Guangdong Huilimin Pest Control Engineering Co. Ltd, Guangzhou, China
Anthony A. James
Roles Visualization, Writing – review & editing
Affiliation: Departments of Microbiology & Molecular Genetics and Molecular Biology & Biochemistry, University of California, Irvine, California, United States of America
Xiao-Guang Chen
Roles Conceptualization, Data curation, Formal analysis, Supervision, Writing – original draft, Writing – review & editing
* E-mail: [email protected]
Affiliation: Department of Pathogen Biology, Institute of Tropical Medicine, School of Public Health, Southern Medical University, Guangzhou, China
ORCID logo https://orcid.org/0000-0002-7927-691X
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2022 Lai et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Background
The surveillance of vector mosquitoes is essential for prevention and control of mosquito-borne diseases. In this study, we developed an internet-based vector mosquito monitor, MS-300, and evaluated its efficiency for the capture of the important vector mosquitoes, Aedes albopictus and Culex quinquefasciatus, in laboratory and field trials.
Methodology/Principal findings
The linear sizes of adult Ae. albopictus and Cx. quinquefasciatus were measured and an infrared window was designed based on these data. A device to specifically attract these two species and automatically transmit the number of captured mosquitoes to the internet was developed. The efficiency of the device in capturing the two species was tested in laboratory, semi-field and open field trials. The efficiency results for MS-300 for catching and identifying Ae. albopictus in laboratory mosquito-net cages were 98.5% and 99.3%, and 95.8% and 98.6%, respectively, for Cx. quinquefasciatus. In a wire-gauze screened house in semi-field trials, the efficiencies of MS-300 baited with a lure in catching Ae. albopictus and Cx. quinquefasciatus were 54.2% and 51.3%, respectively, which were significantly higher than 4% and 4.2% without the lure. The real-time monitoring data revealed two daily activity peaks for Ae. albopictus (8:00–10:00 and 17:00–19:00), and one peak for Cx. quinquefasciatus (20:00–24:00). During a 98-day surveillance trial in the field, totals of 1,118 Ae. albopictus and 2,302 Cx. quinquefasciatus were captured by MS-300. There is a close correlation between the number of captured mosquitoes and the temperature in the field, and a positive correlation in the species composition of the captured samples among the mosquitoes using MS-300, BioGents Sentinel traps and human landing catches.
Conclusions/Significance
The data support the conclusion that MS-300 can specifically and efficiently capture Ae. albopictus and Cx. quinquefasciatus, and monitor their density automatically in real-time. Therefore, MS-300 has potential for use as a surveillance tool for prevention and control of vector mosquitoes.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer