Full text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

It is important to control airborne particles in residential houses for protecting human health. Indoor particulate matter of <2.5 μm (PM2.5) can be effectively monitored and managed using an air purifier. In this study, the actual clean air delivery rates in residential houses (CADRActual) were acquired by comparing decay rates of fine particles with and without operations of the air purifier under actual conditions, following the standard CADR of an air purifier obtained in a closed test chamber. The measurements of CADRActual at different outdoor PM2.5 concentrations over a month in two residential houses revealed different airtightness levels, compared to the standardized clean air delivery rate of the air purifier (CADRAP). Air changes per hour at 50 Pa (ACH50) was 4.8 h−1 for “house A” (built in 2007) and 2.1 h−1 for “house B” (built in 2018). The CADR of the air purifier used in this study was 10.6 m3/min, while the averaged CADRActual at the “house A” was 7.2 m3/min (approximately 66% of the CADR of the air purifier) and 9.5 m3/min at “house B” (approximately 90% of the CADR of the air purifier). Under the outdoor PM2.5 concentrations of <35 μg/m3, the averaged CADRActual of house A and house B were 7.8 ± 0.3 and 9.7 ± 0.4 m3/min, respectively. However, under the outdoor PM2.5 concentrations of >35 μg/m3, the analogous averaged concentrations were 6.8 ± 0.6 and 9.6 ± 0.3 m3/min for houses A and B, respectively. The measured CADRActual agreed well with the theoretical estimates of CADRActual acquired by the mass balance equation using the infiltration rate of ACH50/20. We also estimated CADRActual/CADRAP for house C built in 2017, where the ACH50 was 1.8 h−1. Overall, this study demonstrated how CADRActual/CADRAP of an air purifier at residential houses can be predicted according to outdoor PM2.5 concentration and airtightness of the house. As shown, it can be closer to 1 at lower ACH50 houses and at lower outdoor PM2.5 concentrations.

Details

Title
The Actual Efficacy of an Air Purifier at Different Outdoor PM2.5 Concentrations in Residential Houses with Different Airtightness
Author
Shin, Dongho 1 ; Kim, Younghun 2   VIAFID ORCID Logo  ; Hong, Keejung 1 ; Lee, Gunhee 1 ; Park, Inyong 1 ; Han, Bangwoo 1 

 Department of Sustainable Environment Research, Korea Institute of Machinery & Materials, Daejeon 34103, Korea 
 Department of Sustainable Environment Research, Korea Institute of Machinery & Materials, Daejeon 34103, Korea; Department of Mechanical Engineering, Yonsei University, Seoul 03722, Korea 
First page
616
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
23056304
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2728533388
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.