It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Targeted temperature management (TTM) is recommended following cardiac arrest; however, time to target temperature varies in clinical practice. We hypothesised the effects of a target temperature of 33 °C when compared to normothermia would differ based on average time to hypothermia and those patients achieving hypothermia fastest would have more favorable outcomes.
Methods
In this post-hoc analysis of the TTM-2 trial, patients after out of hospital cardiac arrest were randomized to targeted hypothermia (33 °C), followed by controlled re-warming, or normothermia with early treatment of fever (body temperature, ≥ 37.8 °C). The average temperature at 4 h (240 min) after return of spontaneous circulation (ROSC) was calculated for participating sites. Primary outcome was death from any cause at 6 months. Secondary outcome was poor functional outcome at 6 months (score of 4–6 on modified Rankin scale).
Results
A total of 1592 participants were evaluated for the primary outcome. We found no evidence of heterogeneity of intervention effect based on the average time to target temperature on mortality (p = 0.17). Of patients allocated to hypothermia at the fastest sites, 71 of 145 (49%) had died compared to 68 of 148 (46%) of the normothermia group (relative risk with hypothermia, 1.07; 95% confidence interval 0.84–1.36). Poor functional outcome was reported in 74/144 (51%) patients in the hypothermia group, and 75/147 (51%) patients in the normothermia group (relative risk with hypothermia 1.01 (95% CI 0.80–1.26).
Conclusions
Using a hospital’s average time to hypothermia did not significantly alter the effect of TTM of 33 °C compared to normothermia and early treatment of fever.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer