Full text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Automatic flushing valve (AFV) can improve the anti-clogging ability of the drip fertigation system. The minimum inlet pressure (Hamin) required for automatic closing and the maximum flushing duration (FDmax) are two important performance indexes of AFV. The existing AFV products have the problem of larger Hamin and smaller FDmax, which result higher investment and operating cost, and poor flushing efficiency. Based on the mechanical analysis of the AFV elastic diaphragm and the derivation of the FD, elastic diaphragm hardness (E), ascending channel offset distance (D), and drain hole width (W) were selected as the experimental factors, and nine AFVs were designed by L9(33) orthogonal test method to investigate the influence of elastic diaphragm hardness and structural parameters on the hydraulic performance of AFVs. The hydraulic performance test results showed that the Hamin of the nine AFVs ranged from 0.026 to 0.082 MPa and FDmax ranged from 36.3 to 95.7 s. Hamin was positively correlated with E and D and negatively correlated with W. FDmax was negatively correlated with E and W and tended to increase and then decrease with D. All elastic diaphragm hardness and structural parameters had a significant effect on Hamin, and E and W had a significant effect on FDmax. Based on the range analysis, two new combinations of AFV elastic diaphragm hardness and structural parameters with minimum Hamin (E = 40 HA, D = 0 mm, W = 2 mm) and maximum FDmax (E = 40 HA, D = 2 mm, W = 1.68 mm) were determined, and the corresponding Hamin was 0.022 MPa, 63.3% lower than that of the existing product, and FDmax was 116.4 s, 71.2% higher than that of the existing product. In this study, two ternary nonlinear mathematical regression models of Hamin and FDmax with elastic diaphragm hardness and structural parameters was constructed. The simulation accuracy of the models is good and can be used to quickly predict the optimal combination of AFV parameters to satisfy the actual engineering-required Hamin and FDmax.

Details

Title
Impact of Elastic Diaphragm Hardness and Structural Parameters on the Hydraulic Performance of Automatic Flushing Valve
Author
Gao, Hao 1 ; Mo, Yan 2 ; Wu, Feng 3 ; Wang, Jiandong 4 ; Gong, Shihong 2 

 School of Water Conservancy, North China University of Water Resources and Electric Power, Zhengzhou 450046, China; State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100048, China 
 State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, China Institute of Water Resources and Hydropower Research, Beijing 100048, China 
 School of Water Conservancy, North China University of Water Resources and Electric Power, Zhengzhou 450046, China 
 Institute of Environment and Sustainable Development in Agriculture, Chinese Academy of Agricultural Sciences, Beijing 100081, China 
First page
287
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
20734441
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2767300586
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.