Abstract
Background
It is becoming increasingly evident that the accurate assessment of fluid status is critical to ensure optimal care in patients undergoing hemodialysis (HD). Various fluid parameters, including overhydration (OH) and overhydration/extracellular water (OH/ECW%), which can be obtained using a bioimpedance spectroscopy device have been used to indicate the hydration status in such patients. This study aimed to explore the effect of these fluid parameters on cardiovascular events and determine which parameter was a better predictor of cardiovascular events (CVEs).
MethodsA total of 227 patients who underwent HD at the Hangzhou Hospital of Traditional Chinese Medicine were enrolled in this prospective study between December 2017 and August 2018. Clinical data were collected, and the fluid status of patients was assessed using a body composition monitor. The patients were followed up until December 2020. The primary outcomes were CVEs. The association between fluid parameters and CVEs was analyzed using Cox proportional hazards models. The areas under the curve (AUCs) of receiver operating characteristic analysis and improvement in the global chi-squared value were used to compare the predictive values of fluid parameters for CVEs.
ResultsDuring a median follow-up of 31 months, 66 CVEs were recorded. The patients with a higher absolute hydration index (OH) and a relative hydration index (OH/ECW%) exhibited an increased risk of developing CVEs. After adjusting for confounding factors, both OH [hazard ratio (HR) 1.279 per L, 95% confidence interval (CI) 1.047–1.562; p = 0.016] and OH/ECW% (HR 1.061 per %, 95% CI 1.017–1.108; p = 0.006) were independently associated with CVEs. The predictive ability of the absolute hydration index was superior to the relative hydration index based on AUC calculations for CVEs. Furthermore, a greater change in χ2 in predicting CVEs was noted for the absolute hydration index.
ConclusionsBoth absolute hydration index and relative hydration index were found to be independent predictors of CVEs in univariate and multivariate analyses. Furthermore, the absolute hydration index had a better additive predictive value than the relative hydration index in predicting CVEs.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details
1 Department of Nephrology, Hangzhou TCM Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China