Abstract
Background
To compare the clinical outcomes of patients undergoing sequential pars plana vitrectomy (PPV) followed by cataract extraction surgery (CE) [PPV/CE], simultaneous PPV and CE (PPV + CE), and sequential CE followed by PPV [CE/PPV].
Methods
A retrospective observational cohort study of 427 eyes of 404 patients who underwent either sequential or simultaneous PPV and CE surgery between March 2016 and May 2021. Pre-operative and post-operative assessments (up to 2 years of follow-up visits) of uncorrected visual acuity (UCVA), corrected distance visual acuity (CDVA), spherical equivalent (SEQ), and refractive prediction error (RPE) was done. Main outcome measures were both visual (UCVA, CDVA) and refractive (RPE, SEQ).
Results
There was a statistically significant difference in CDVA of the PPV/CE, PPV + CE, CE/PPV groups (logMAR 0.34 ± 0.40, 0.65 ± 0.61, and 0.55 ± 0.60, respectively) at one month postoperatively (POM1) (P < 0.001), and at the POM12 visits (logMAR 0.25 ± 0.34, 0.53 ± 0.68, and 0.44 ± 0.48; P = 0.04). In the subgroup analysis of patients with a diagnosis of either epiretinal membrane or vitreous opacities, there was no statistically significant difference in SEQ (P = 0.09) and RPE (P = 0.13) at the combined 1 month and 3 month visits.
Conclusion
Simultaneous PPV and cataract surgery demonstrated similar improvements in visual acuity and refractive outcomes, as well as comparable intraoperative and postoperative complication profiles to sequential surgery.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer