Full Text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background and Objectives: Bleeding is one of the most feared and frequent adverse events in the case of EUS-guided drainage of WOPN using lumen-apposing metal stents (LAMSs) and of direct endoscopic necrosectomy (DEN). When it occurs, its management is still controversial. In the last few years, PuraStat, a novel hemostatic peptide gel has been introduced, expanding the toolbox of the endoscopic hemostatic agents. The aim of this case series was to evaluate the safety and efficacy of PuraStat in preventing and controlling bleeding of WOPN drainage using LAMSs. Materials and Methods: This is a multicenter, retrospective pilot study from three high-volume centers in Italy, including all consecutive patients treated with the novel hemostatic peptide gel after LAMSs placement for the drainage of symptomatic WOPN between 2019 and 2022. Results: A total of 10 patients were included. All patients underwent at least one session of DEN. Technical success of PuraStat was achieved in 100% of patients. In seven cases PuraStat was placed for post-DEN bleeding prevention, with one patient experiencing bleeding after DEN. In three cases, on the other hand, PuraStat was placed to manage active bleeding: two cases of oozing were successfully controlled with gel application, and a massive spurting from a retroperitoneal vessel required subsequent angiography. No re-bleeding occurred. No PuraStat-related adverse events were reported. Conclusions: This novel peptide gel could represent a promising hemostatic device, both in preventing and managing active bleeding after EUS-guided drainage of WON. Further prospective studies are needed to confirm its efficacy.

Details

Title
The Use of PuraStat® in the Management of Walled-Off Pancreatic Necrosis Drained Using Lumen-Apposing Metal Stents: A Case Series
Author
Binda, Cecilia 1   VIAFID ORCID Logo  ; Fugazza, Alessandro 2   VIAFID ORCID Logo  ; Fabbri, Stefano 1   VIAFID ORCID Logo  ; Coluccio, Chiara 1   VIAFID ORCID Logo  ; Repici, Alessandro 3 ; Tarantino, Ilaria 4 ; Anderloni, Andrea 5   VIAFID ORCID Logo  ; Fabbri, Carlo 1   VIAFID ORCID Logo 

 AUSL Romagna, Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, 47121 Forlì-Cesena, Italy 
 Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, 20089 Milan, Italy 
 Humanitas Research Hospital, Digestive Endoscopy Unit, Division of Gastroenterology, Rozzano, 20089 Milan, Italy; Humanitas University, Department of Biomedical Sciences, 20090 Pieve Emanuele, Italy 
 Digestive Endoscopy and Gastroenterology Unit, Department of Gastroenterology, Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (IsMeTT/UPMC), 90127 Palermo, Italy 
 Fondazione I.R.C.C.S. Policlinico San Matteo, Gastroenterology and Digestive Endoscopy Unit, 27100 Pavia, Italy 
First page
750
Publication year
2023
Publication date
2023
Publisher
MDPI AG
ISSN
1010660X
e-ISSN
16489144
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2806574430
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.