It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Objective
To investigate whether left atrial (LA) volume and left ventricular filling pressure (LVFP) assessed by cardiovascular magnetic resonance (CMR) change during adenosine delivered myocardial hyperaemia as part of a first-pass stress perfusion study.
Methods and results
We enrolled 33 patients who had stress CMR. These patients had a baseline four-chamber cine and stress four-chamber cine, which was done at peak myocardial hyperaemic state after administering adenosine. The left and right atria were segmented in the end ventricular diastolic and systolic phases. Short-axis cine stack was segmented for ventricular functional assessment. At peak hyperaemic state, left atrial end ventricular systolic volume just before mitral valve opening increased significantly from baseline in all (91 ± 35ml vs. 81 ± 33ml, P = 0.0002), in males only (99 ± 35ml vs. 88 ± 33ml, P = 0.002) and females only (70 ± 26ml vs. 62 ± 22ml, P = 0.02). The right atrial end ventricular systolic volume increased less significantly from baseline (68 ± 21ml vs. 63 ± 20ml, P = 0.0448). CMR-derived LVFP (equivalent to pulmonary capillary wedge pressure) increased significantly at the peak hyperaemic state in all (15.1 ± 2.9mmHg vs. 14.4 ± 2.8mmHg, P = 0.0002), females only (12.9 ± 2.1mmHg vs. 12.3 ± 1.9mmHg, P = 0.029) and males only (15.9 ± 2.8mmHg vs. 15.2 ± 2.7mmHg, P = 0.002) cohorts.
Conclusion
Left atrial volume assessment by CMR can measure acute and dynamic changes in preloading conditions on the left ventricle. During adenosine administered first-pass perfusion CMR, left atrial volume and LVFP rise significantly.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer