Full text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Previous studies have demonstrated the energy- and water-saving potentials of showering facilities in residential buildings. However, the prospect of public showering places where multiple showerheads usually worked together according to their opening hours has often been overlooked and rarely investigated. This study measured the water flow rate in a water supply pipe to understand the water-use patterns and water consumption of showering facilities in a swimming pool. The measurements were carried out on typical cold and warm days. The results showed that the average water consumption was 50.5 L/person in December (T = 19.7 °C) and 38.6 L/person in April (T = 24.5 °C). The fluctuation of the water flow rate demonstrated a water demand pattern for the showering facilities, where the maximum water flow rate was more than twice the average level, indicating inefficient working modes of the water supply pump. To improve the current situation, an appropriately sized water tank was suggested to be installed, which could ensure a more stable water flow rate in the main supply pipe, enhancing the water supply system efficiency and saving energy for the water pump. These results contribute to establishing the design data for optimizing water tank design in swimming pools or similar buildings with public showering demand and illustrate the energy-saving potential of water supply systems in showering facilities. Nevertheless, the results of this study are only based on theoretical calculations. More comprehensive field studies with a water tank are required to confirm these findings and better elucidate the effects.

Details

Title
Optimizing the Pump Storage System for Hot Water Showering at Swimming Pools
Author
Wong, Ling-Tim  VIAFID ORCID Logo  ; Chun-San, Chan  VIAFID ORCID Logo  ; Kwok-Wai Mui; Zhang, Dadi  VIAFID ORCID Logo 
First page
2083
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
20734441
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2824049921
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.