It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Electrical impedance tomography (EIT) utilizes voltage/current data measured from the surface of interest to reconstruct the electrical conductivity distribution. This results in a noninvasive medical imaging procedure with many applications. Some examples would be: lung ventilation monitoring, breast cancer detection, and fatty liver detection. Non-alcoholic fatty liver disease (NAFLD) is one of the most common causes of cardiometabolic diseases in overweight individuals. The gold standard for NAFLD diagnosis is a liver biopsy which is a risky and invasive procedure. A non-invasive and cost effective method to detect fatty liver is an important unmet clinical need. Due to the distinct electrical properties of fatty tissue versus normal tissue, EIT can be applied to detect the fat infiltrate in the liver. We conducted EIT measurements and reconstructions on 19 subjects where the fat infiltrate was validated by MRI proton-density fat fraction (PDFF). The liver EIT conductivity was shown to be inversely correlated with MRI PDFF, demonstrating the ability of EIT to detect fatty infiltrate in the liver.
This thesis also extends the EIT reconstruction to detect atherosclerosis, which is a build-up of fatty tissue in the arteries (plaque). Some plaques are prone to rupture and the current gold standard has a false negative rate of 20 % when distinguishing between vulnerable plaque and stable plaque. We sought to use EIT to detect the fatty content (mainly oxidize LDL) inside these vulnerable plaques. Therefore, the reconstruction method was modified into an outward setting that can measure from the inner surface of interest. Ex vivo experiments have demonstrated the ability to detect the location of fatty tissue in swine aorta. This technique has the potential to detect vulnerable plaque. However, the dimension of the device and the required electrode number limits the application from in vivoanimal artery experiments.
Finally EIS-derived EIT, a new method we proposed, utilizes impedance values at a fixed frequency to solve for the conductivity distribution. This approach circumvents the mathematically ill-posed problem found when performing traditional EIT methods. We designed a 6-point EIS electrode array that was circumferentially configured to a balloon catheter and deployed in Yorkshire mini-pigs with induced stenosis in the right carotid artery. The EIS spectra demonstrated an elevated impedance in the right carotid arteries and the EIS-derived EIT mappings were reconstructed. The low conductivity regions in the EIS-derived EIT mappings were correlated with the positive E06 immunostaining for oxLDL-laden regions. Thus, we establish the capability of 3D EIS-derived EIT to detect oxLDL-laden arterial walls with translational implication to predict metabolically active plaques prone to acute coronary syndromes.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer