Abstract
Objective
Despite the studies that have investigated the reliability of Upper Extremity Functional Tests(UEFTs), the reliability of Closed Kinetic Chain Upper Extremity Stability(CKCUES), Seated Medicine Ball Throw(SMBT), push-up(PU) and Unilateral Seated Shot Put(USSP) tests in overhead athletes has yet to be assessed. The objective of this study was to determine both the relative and absolute test–retest reliability of the four UEFTs in female overhead athletes.
Methods
Twenty-nine female overhead athletes (age: 26.6 ± 5.29 years) underwent the four UEFTs twice within a three- day interval. The upper limb stability was assessed through PU and CKCUES tests, while the power was assessed though SMBT and USSP tests. The Intraclass Correlation of Coefficient (ICC) was applied to assess the relative reliability. Absolute reliability was determined by calculating the Standard Error of Measurement (SEM) and the Minimal Detectable Change (MDC). Furthermore, Bland–Altman plots were used to detect the agreements between the two measurements.
Results
The relative reliability of PU, CKCUES, SMBT, and non-dominant arm USSP tests was excellent (ICC = 0.83, 0.80, 0.91, and 0.83, respectively). SEM was within a range of 1.69 to 1.72 for stability tests and a range of 13.61 to 52.12 for power (based on a 95% confidence interval). The MDC was 4.68 for PU and 4.75 for CKCUES test. At least four repetitions are needed to be considered a real improvement on PU and CKCUES tests. This value was 144.04, in SMBT and 59.03, 37.62 cm (dominant and non-dominant arm, respectively) in USSP tests, which represents the minimum change that must occur to be considered an athlete’s progression.
Conclusion
This study revealed that both the upper limb stability and power tests have acceptable relative and absolute intra-rater reliability in female overhead athletes. These can be considered as reliable tools in research and clinical settings.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer