Abstract

Background

For femoral neck fractures in young and middle-aged patients, both fibula allograft with cannulated screw fixation and ordinary cannulated screw fixation are clinically effective treatments. However, for unstable femoral neck fractures, ordinary cannulated screw fixation is characterized by a high risk of postoperative complications and a high rate of mechanical failure after internal fixation. For this study, we systematically compared the long-term efficacy and postoperative complications of these two procedures.

Methods

A total of 156 subjects diagnosed as femoral neck fractures participated in our study. Subjects in the combination group underwent fibula allograft with cannulated screw fixation (n = 76), and those in the control group were treated with ordinary cannulated screw fixation (n = 80). Baseline characteristics, perioperative outcomes, Harris hip score (HHS) and EuroQoL five-dimension questionnaire (EQ-5D); and the incidence of postoperative and bone healing complications in the two groups were recorded and compared.

Results

The average follow-up time was more than 10 years. Intra-operative blood loss significantly increased in the combination group compared with the control group (P < 0.05). There were significantly improved performances in healing time, the time course of recovery of full-weight-bearing stepping, HHS and EQ-5D scores in the combination group compared with the control group (P < 0.05). Besides, the incidence rates of femoral head necrosis, nonunion, femoral neck shortening and total hip replacement were significantly lower in the combination group than those in the control group (P < 0.05).

Conclusion

Fibula allograft with cannulated screw fixation shows a better long-term therapeutic effect than ordinary cannulated screw fixation for femoral neck fractures in young and middle-aged patients. Patients receiving the combination strategy have faster and high-quality functional recovery after femoral neck fractures and a lower incidence rate of postoperative complications.

Details

Title
Fibula allograft with cannulated screw fixation versus ordinary cannulated screw fixation for femoral neck fractures: a 10-year retrospective comparative study
Author
Yangwenxiang Wei; Lin, Tianye; Liu, Yuhao; Chen, Zhenqiu; Zhou, Chi
Pages
1-9
Section
Research Article
Publication year
2023
Publication date
2023
Publisher
BioMed Central
e-ISSN
1749-799X
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2852150200
Copyright
© 2023. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.