Full Text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Water management is an important criterion in the operation of proton-exchange membrane fuel cells to maintain the high performance and reliability of the system. The water content in the cathode air that is supplied to the cathode channel contributes to the membrane humidification and the transport of protons inside the membrane structure. In automotive applications, the supply air is typically driven through an external membrane humidifier to absorb more moisture from the recirculated cathode exhaust. In the literature, humidifiers and fuel cell stacks have been separately investigated without considering whole-system configurations for water management. This study investigates changes in the cathode air characteristics through a membrane humidifier and compares two configurations using a humidifier bypass of the supply flow and exhaust flow to adjust the cathode inlet air relative humidity. Each component in the system was modeled using mathematical relations and converted into blocks of inputs and outputs in MATLAB/Simulink for simulation. The bypass valve was demonstrated to effectively reduce the relative humidity of the supply air from the saturation rate to above 60%, with a bypass fraction of up to 0.6 in both configurations. These adjustments provide system flexibility to accommodate load changes and prevent flooding in the stack channels. Bypassing the supply air through the humidifier effectively maintained consistent cathode inlet humidity across a wide operational range. A 0.4 bypass fraction on the supply side sustained a relative humidity of around 80% for the whole range of operating flow rates. In contrast, the exhaust-side bypass had a smaller impact, and the relative humidity of the cathode air was reduced when the flow rate and bypass fraction increased. This study further supports the control system design to regulate the bypass fraction according to load transients.

Details

Title
Bypass Configurations of Membrane Humidifiers for Water Management in PEM Fuel Cells
Author
Hoang Nghia Vu 1   VIAFID ORCID Logo  ; Dinh Hoang Trinh 1 ; Dat Truong Le Tri 1 ; Yu, Sangseok 2 

 Department of Mechanical Engineering, Graduate School, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea; [email protected] (H.N.V.); [email protected] (D.H.T.); [email protected] (D.T.L.T.) 
 School of Mechanical Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea 
First page
6986
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
19961073
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2876599923
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.