Abstract
Objective
To establish a finite element model of meniscus horizontal cleavage and partial resection, to simulate the mechanical changes of knee joint under 4 flexion angles, and to explore what is the optimal surgical plan.
Methods
We used Mimics Research, Geomagic Wrap, and SolidWorks computer software to reconstruct the 3D model of the knee joint, and then produced the horizontal cleavage tears model of the internal and lateral meniscus, the suture model, and the partial meniscectomy model. These models were assembled into a complete knee joint in SolidWorks software, and corresponding loads and boundary constraints were added to these models in ANSYS software to simulate the changing trend of pressure and shear force on femoral condylar cartilage, meniscus, and tibial cartilage under the flexion angles of 0°, 10°, 20°, 30° and 40° of the knee joint. At the same time, the difference of force area between medial interventricular and lateral interventricular of knee joint under four states of bending the knee was compared, to explore the different effects of different surgical methods on knee joint after horizontal meniscus tear.
Results
Within the four medial meniscus injury models, the lowest peak internal pressure and shear force of the knee joint was observed in the meniscal suture model; the highest values were found in the bilateral leaflet resection model and the inferior leaflet resection model; the changes of pressure, shear force and stress area in the superior leaflet resection model were the most similar to the changes of the knee model with the meniscal suture model.
Conclusion
Suture repair is the best way to maintain the force relationship in the knee joint. However, resection of the superior leaflet of the meniscus is also a reliable choice when suture repair is difficult.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer