Full text

Turn on search term navigation

Copyright © 2023 Palaniappan Prasath et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/

Abstract

The performance of structural composites during loading has always been a concern for the designers and construction industry since the reinforced concrete structure was discovered. In this study, lateral load–displacement behavior of beam–column joints wrapped with aramid fiber is evaluated using both experimental and numerical analysis subjected to torsional moment (beam-eccentric loading). Three categories of reinforcement concepts are adopted for the preparation of the beam–column joints, where members are wrapped with aramid fiber at the joints, and others are not fortified with aramid fibers. Prior to testing, the structural composites are cured for maximum 28 days into water. The beam–column joints are subjected to lateral load at a point near the column end of the beam–column connection, and the corresponding deflections are measured until the member fails. Based on the test results, ductility and energy absorption capacity are evaluated. The findings of the numerical investigation of beam–column joint show there is not much variation in the experimental and numerical analysis; it is clearly found that aramid fiber wrapping provided large rigidity in the joint, and it is also prolonged the final failure of the joints. This study shows that in addition to the conventional reinforcement, providing the hanger reinforcement and the diagonal reinforcement improves the rigidity of the beam–column joints during severe loadings, as this study described.

Details

Title
Torsional Modeling of Reinforced Concrete Beam–Column Joint Retrofitted by Aramid Fiber—Experimental and Numerical Analysis
Author
Palaniappan Prasath 1 ; Ravindran Gobinath 2   VIAFID ORCID Logo  ; Jayaprakash Sridhar 3   VIAFID ORCID Logo 

 Department of Civil Engineering, Muthayammal College of Engineering, Rasipuram, Tamil Nadu, India 
 Department of Civil Engineering, SR University, Warangal 506371, Telangana, India 
 Department of Civil Engineering, GMR Institute of Technology, Rajam, Andhra Pradesh 532127, India 
Editor
Junqing Zuo
Publication year
2023
Publication date
2023
Publisher
John Wiley & Sons, Inc.
ISSN
16878086
e-ISSN
16878094
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2879845853
Copyright
Copyright © 2023 Palaniappan Prasath et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0/