Abstract

A suggested value for the length of each drawn line would appear in the toolbar and then the ratio of the width to the length could be calculated according to these suggested values. [...]this step of calculation of CVI would compensate for the concern raised by Dr. Motamed Shariati. In the present study, we selected a region of interest with a total width of 3000 microns; thus, this could explain the larger area of TCA reported in our study.

Details

Title
Image Calibration in choroidal vascularity index measurement
Author
Hassanpour, Kiana; Ahmadieh, Hamid
Pages
1-2
Section
Letter to the Editor
Publication year
2023
Publication date
2023
Publisher
BioMed Central
e-ISSN
20569920
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2890078940
Copyright
© 2023. This work is licensed under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.