Full text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

A new fast, sensitive, and environmentally friendly analytical method has been developed for the simultaneous determination of Ba, Be, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, and Zn in wastewater samples using inductively coupled plasma optical emission spectroscopy (ICP OES). A preconcentration step using a magnetic dispersive solid-phase extraction (MDSPE) technique with a new magnetic sorbent was performed. The new sorbent material was a carbon containing magnetic cobalt and nitrogen groups. This material was synthetized using controlled pyrolysis of a zeolitic imidazolate framework (i.e., ZIF-67). In order to optimize the experimental parameters that affect the MDSPE procedure, a multivariate optimization strategy, using Plackett–Burman and circumscribed central composite designs (CCD), was used. The method has been evaluated employing optimized experimental conditions (i.e., sample weight, 10 g; sample pH, 7.6; amount of sorbent, 10 mg; dispersive agent, vortex; complexing agent concentration, 0.5%; ionic concentration, 0%; eluent, HCl; eluent concentration, 0.5 M; eluent volume, 300 μL; elution time, 3 min and extraction time, 3 min) using external calibration. Limits of detection (LODs) in a range from 0.073 to 1.3 μg L−1 were obtained, and the repeatability was evaluated at two different levels, resulting in relative standard deviations below 8% for both levels (n = 5). An increase in the sensitivity was observed due to the high enrichment factors (i.e., 3.2 to 13) obtained compared with direct ICP OES analysis. The method was also validated through carrying out recovery studies that employed a real wastewater sample and through the analysis of a certified reference material (ERM®-CA713). The recovery values obtained with the real wastewater were between 94 and 108% and between 90 and 109% for the analysis of ERM®-CA713, showing negligible matrix effects.

Details

Title
Enhancing Trace Metal Extraction from Wastewater: Magnetic Activated Carbon as a High-Performance Sorbent for Inductively Coupled Plasma Optical Emission Spectrometry Analysis
Author
Abellán-Martín, Sergio J 1 ; Villalgordo-Hernández, David 2   VIAFID ORCID Logo  ; Aguirre, Miguel Ángel 1 ; Ramos-Fernández, Enrique V 2   VIAFID ORCID Logo  ; Narciso, Javier 3 ; Canals, Antonio 1 

 Department of Analytical Chemistry and Food Science, University Institute of Materials, Faculty of Science, University of Alicante, P.O. Box 99, 03080 Alicante, Spain; [email protected] 
 Department of Inorganic Chemistry, University Institute of Materials, Faculty of Science, University of Alicante, P.O. Box 99, 03080 Alicante, Spain; [email protected] (D.V.-H.); [email protected] (E.V.R.-F.); [email protected] (J.N.) 
 Department of Inorganic Chemistry, University Institute of Materials, Faculty of Science, University of Alicante, P.O. Box 99, 03080 Alicante, Spain; [email protected] (D.V.-H.); [email protected] (E.V.R.-F.); [email protected] (J.N.); Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), 03010 Alicante, Spain 
First page
563
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
22978739
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2893318758
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.