Full text

Turn on search term navigation

© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

The proliferation and great variety of low-cost air quality (AQ) sensors, combined with their flexibility and energy efficiency, gives an opportunity to integrate them into Wireless Sensor Networks (WSN). However, with these sensors, AQ monitoring poses a significant challenge, as the data collection and analysis process is complex and prone to errors. Although these sensors do not meet the performance requirements for reference regulatory-equivalent monitoring, they can provide informative measurements and more if we can adjust and add further processing to their raw measurements. Therefore, the integration of these sensors aims to facilitate real-time monitoring and achieve a higher spatial and temporal sampling density, particularly in urban areas, where there is a strong interest in providing AQ surveillance services since there is an increase in respiratory/allergic issues among the population. Leveraging a network of low-cost sensors, supported by 5G communications in combination with Artificial Intelligence (AI) techniques (using Convolutional and Deep Neural Networks (CNN and DNN)) to predict 24-h-ahead readings is the goal of this article in order to be able to provide early warnings to the populations of hazards areas. We have evaluated four different neural network architectures: Multi-Linear prediction (with a dense Multi-Linear Neural Network (NN)), Multi-Dense network prediction, Multi-Convolutional network prediction, and Multi-Long Short-Term Memory (LSTM) network prediction. To perform the training of the prediction of the readings, we have prepared a significant dataset that is analyzed and processed for training and testing, achieving an estimation error for most of the predicted parameters of around 7.2% on average, with the best option being the Multi-LSTM network in the forthcoming 24 h. It is worth mentioning that some pollutants achieved lower estimation errors, such as CO2 with 0.1%, PM10 with 2.4% (as well as PM2.5 and PM1.0), and NO2 with 6.7%.

Details

Title
AI-IoT Low-Cost Pollution-Monitoring Sensor Network to Assist Citizens with Respiratory Problems
Author
Felici-Castell, Santiago 1   VIAFID ORCID Logo  ; Segura-Garcia, Jaume 1   VIAFID ORCID Logo  ; Perez-Solano, Juan J 1   VIAFID ORCID Logo  ; Fayos-Jordan, Rafael 2   VIAFID ORCID Logo  ; Soriano-Asensi, Antonio 1   VIAFID ORCID Logo  ; Alcaraz-Calero, Jose M 2   VIAFID ORCID Logo 

 Escola Tècnica Superior d’Enginyeria, Universitat de València, Campus de Burjassot, 46100 Valencia, Spain; [email protected] (J.J.P.-S.); [email protected] (A.S.-A.) 
 School of Computing, Engineering and Physical Sciences, University of West of Scotland, Storie Street, Paisley PA1 2HB, UK; [email protected] (R.F.-J.); [email protected] (J.M.A.-C.) 
First page
9585
Publication year
2023
Publication date
2023
Publisher
MDPI AG
e-ISSN
14248220
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2899458383
Copyright
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.