It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
Spontaneous intracerebral hemorrhage (ICH) is a condition associated with high mortality and morbidity. Survivors may require prolonged intubation with mechanical ventilation (MV). The aim of this study was to analyze the predictors of extubation failure and prolonged MV in patients who undergo surgical evacuation.
Methods
This retrospective study was conducted on adult patients with ICH who underwent MV for at least 48 h and survived > 14 days after surgery. The demographics, clinical characteristics, laboratory tests, and Glasgow Coma Scale score were analyzed.
Results
A total of 134 patients with ICH were included in the study. The average age of the patients was 60.34 ± 15.59 years, and 79.9% (n = 107) were extubated after satisfying the weaning parameters. Extubation failure occurred in 11.2% (n = 12) and prolonged MV in 48.5% (n = 65) patients. Multivariable regression analysis revealed that a white blood cell count > 10,000/mm3 at the time of extubation was an independent predictor of reintubation. Meanwhile, age and initial Glasgow Coma Scale scores were predictors of prolonged MV.
Conclusions
This study provided the first comprehensive characterization and analysis of the predictors of extubation failure and prolonged MV in patients with ICH after surgery. Knowledge of potential predictors is essential to improve the strategies for early initiation of adequate treatment and prognosis assessment in the early stages of the disease.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer