Introduction
Physical activity (PA) and exercise-based cardiac rehabilitation are paramount for preventing and managing cardiovascular diseases (CVD) such as heart failure (HF).1 HF patients with higher levels of moderate to vigorous PA (MVPA) show better quality of life and lower hospitalization and mortality rates.2 Unsurprisingly, PA is an important target for improving clinical outcomes in HF.3
However, assessing the daily PA profile is a challenging task, traditionally performed using self-report questionnaires such as the International PA Questionnaire (IPAQ).4 The IPAQ Short and Long Form (IPAQ-SF and IPAQ-LF) are instruments designed primarily for population-based surveillance of PA in adults. They have been developed and tested for use in healthy adults aged 15 to 69 years, across different countries and income levels.5 Even though the IPAQ has not been recommended for research studies that require precise PA quantification to examine changes at the individual level, the questionnaire has been widely used in this context,6 and both the IPAQ-SF and IPAQ-LF have been applied in populations with clinical conditions such as cancer, fibromyalgia, osteoarthritis, orthopaedic injury, schizophrenia, multiple sclerosis, chronic kidney disease, and HF.7–15
Methods for assessing PA have evolved from behavioural observation and self-report using interviews, questionnaires, and diaries to device-based measures using accelerometers, pedometers, armbands, and other instruments that can directly assess one or more dimensions of PA (e.g. frequency, intensity, time, and type) and have the ability to capture a variety of metrics such as number of steps, minutes of activity, intensity of activity, and bouts of activity.16,17
The literature shows that self-reported measures have important limitations, including recall bias, missingness, and low precision for measuring time in MVPA, while accelerometers cannot capture the context of PA.16,18–20 Thus, questionnaires and device-based measures should be applied simultaneously, as they capture different aspects of PA and may influence each other. Device-based measures such as accelerometry provide more consistent results for assessing time in MVPA and estimating rates of adherence to PA guidelines. Nevertheless, their precision in estimating PA levels depends on standardized data collection and processing criteria.21 Regarding data collection, there is no consensus about which wear protocol (i.e. waking hours and 24 h) to use for assessing MVPA in CVD patients.22 As for processing criteria, the selection of software (e.g. ActiLife and GGIR) and/or acceleration metrics (e.g. counts/min and raw acceleration) to convert raw acceleration data for analyses has a crucial impact on the accelerometer outcomes.21 Cut-points have been the most widely used method to link accelerometer metrics with PA intensity (i.e. sedentary, light, moderate, and vigorous).23
A recently published review22 assessed the methods used for collecting and processing accelerometer data in HF patients, reporting that Freedson et al.'s24 cut-points are the most frequently used. Troiano et al.'s25 cut-points were also used in one study. Both sets of cut-points were calibrated and validated in healthy adults. Two subsequent studies12,26 that would have met the review's inclusion criteria applied Dibben et al.'s27 cut-points, which were calibrated and validated in HF patients, and Santos-Lozano et al.'s28 cut-points, which were calibrated and validated in healthy older adults. Another study in patients with coronary artery disease29 used Mark et al.'s30 cut-points, which were calibrated and validated in the same population. Adults with chronic diseases31 have been assessed using Hildebrand et al.'s32 cut-points, which were calibrated and validated in health adults; lung cancer patients33 using Barnett et al.'s34 cut-points; and those with metabolic syndrome35 using Sanders et al.'s cut-points.36 The latter two sets of cut-points were both calibrated and validated in healthy adults.
The IPAQ-SF has been widely used to monitor PA and compare it with accelerometer measurements. Published studies in clinical populations show different levels of concordance, ranging from significant correlation to no correlation at all. These disparities have been observed in both total PA and PA intensity levels.8,9,11,12,37
In HF studies, Schmidt et al.12 challenged the validity of the IPAQ-SF, suggesting that self-reported measures overestimate MVPA in patients with HF with preserved ejection fraction (HFpEF). Additionally, according to accelerometry measures, these patients spent little time in MVPA, which was the only PA pattern positively associated with prognostic indicators.12 However, the certainty of these results was limited by the study's small sample size (n = 24) and the single cut-point value used.28 Moreover, there were no previous studies that correlated IPAQ-SF with accelerometer-derived data conducted in patients with HF with mildly reduced (HFmrEF) or reduced ejection fraction (HFrEF).
This study aims to assess the concurrent validity of the IPAQ-SF and accelerometer-assessed PA using six published cut-points in patients with HF (i.e. HFmrEF or HFrEF).
Methods
Participants and design
This study took place at the Dr Balmis General University Hospital (Alicante, Spain). Patients with HFmrEF (left ventricular ejection fraction [LVEF]: 41% to 49%) or HFrEF (LVEF: ≤40%), as confirmed by an attending cardiologist in the HF unit, were consecutively recruited from December 2020 to July 2022. Inclusion criteria were aged 18 years or older, LVEF of less than 50%, and able to walk independently of aids. Exclusion criteria were incapacity for ambulatory movement and the inability to understand verbal and written Spanish instructions. Eligible patients were invited to participate, and those who provided written informed consent were included.
Procedure
Participants received an accelerometer and instruction sheet on how to wear it for a period of 7 days (see Appendix S1). Anthropometric variables (i.e. weight, height, and body mass index) were recorded, as were clinical characteristics (e.g. aetiology and co-morbidities) collected from medical records. LVEF was measured by echocardiography, which was performed by an experienced cardiologist using an ultrasound system. Images were obtained during a breath hold. Cardiac chamber dimensions, volumes, and LV diastolic function were measured following the American Society of Echocardiography guidelines.38 LV systolic function was evaluated by calculating biplane ejection fraction (Simpson's method). After returning accelerometers (i.e. on the eighth day), the IPAQ-SF and sociodemographic variables were collected through a personal interview. The period assessed using the IPAQ-SF was the same as for the accelerometer record (i.e. the previous 7 days).
International Physical Activity Questionnaire - Short Form
The Spanish translation of the IPAQ-SF (Appendix S2) was used to assess self-reported PA. The IPAQ-SF evaluates the number of days and time spent performing MVPA, walking, and sitting in bouts of at least 10 min over the previous 7 days. The summary score is expressed in PA metabolic equivalent of task (MET)-min per day or week.
Calculation of moderate to vigorous physical activity time in metabolic equivalent of task-minutes
In this study, MET-min were estimated for each participant and classified according to the cumulative weekly MET-min following the IPAQ-SF analysis instructions4 for both IPAQ-SF and accelerometry data. Specifically, IPAQ-SF weekly MET-min were calculated by adding MET-min of moderate PA (4.0 MET-min/min), vigorous PA (8.0 MET-min/min), and walking (3.3 MET-min/min).4 Total weekly MET-min from accelerometers were calculated by adding the MET-min of moderate PA (4.0 MET-min/min), and vigorous PA (8.0 MET-min/min). The cumulative weekly MET-min were then used to classify participants into three categories4:
- low PA (individuals who did not meet criteria for moderate or high categories);
- moderate PA (≥3 days of vigorous-intensity activity of at least 20 min per day; ≥5 days of moderate-intensity activity and/or walking of at least 30 min per day; or 3–5 or more days of any combination of walking, moderate-intensity or vigorous intensity activities achieving a minimum total PA of at least 600 MET-min/week);
- high PA (vigorous activity on at least 3 days with a minimum total PA of at least 1500 MET-min/week or 7 days of any combination of walking and moderate or vigorous activities with a minimum total PA of 3000 MET-min/week).
Accelerometers and processing data
Device-based measures of PA were assessed for 7 days using an accelerometer (wGT3X-BT, ActiGraph, Pensacola, FL, USA) worn on the right hip, using waking-hour or 24 h wear protocol.22 Accelerometer data were processed and analysed either with ActiLife software (for count-based cut-points) or the GGIR package in R (for raw acceleration-based cut-points). Processing details can be found in the supporting information (ActiLife: Appendix S3; GGIR: RStudio script, Appendix S4). Six different cut-points, validated in patients with CVD,27,30 older adults,34,36 and adults,25,40 were applied to calculate time spent in MVPA (Appendices S5 and S6), which was then translated to MET-min.4 Steps/min outcomes from accelerometers were treated41,42 to assess walking cadence and intensity in bouts of at least 10 min (Appendix S7).
Wear time validation was performed in line with previous studies,22,43 including at least three weekdays and one weekend day of 10 h/day or more of monitoring for the waking-hour protocol and at least 16 h/day of monitoring for the 24 h protocol. Non-wear time in ActiLife was identified as at least 90 consecutive minutes of zero activity counts, with allowance for 2 min of activity counts between 0 and 100.44 Non-wear time in GGIR was estimated based on the standard deviation and the value range of the raw data from each accelerometer axis. Classification was done per 15-min block and based on the characteristics of the 60-min window, centred at these 15 min. A block was classified as non-wear time if the standard deviation of the 60-min window was <13 milligravities (mg, 1 mg = 0.00981 m·s−2) and the value range of the 60-min window was <50 mg, for at least two out of the three accelerometer axes.45 Bouted and non-bouted minutes of MVPA were calculated. An MVPA bout was defined as ≥10 consecutive min above the MVPA cutoff, with the allowance of 2 min below the cutoff.46 Bouted minutes of MVPA were determined as mean daily minutes in MVPA bouts. Non-bouted MVPA was determined as the daily average of the total MVPA minutes.
Data analysis
Patients' characteristics were reported as means (standard deviation) for continuous variables and as absolute and relative frequency for categorical variables. The Shapiro–Wilk test and box plots were used to test the normality of the distribution. Non-parametrically distributed values were expressed as medians (interquartile range). Percentiles were calculated as the weighted mean. The Spearman correlation coefficient was used to study the correlation between IPAQ-SF and accelerometry-derived MET-min based on the selected cut-points. The magnitude of correlations was described as follows: 0.00 to 0.30, negligible; 0.31 to 0.50, low; 0.51 to 0.70, moderate; 0.71 to 0.90, high; and 0.91 to 1.00, very high. The absolute bias for each cut-point was calculated as the difference between IPAQ-SF and accelerometry-derived MET-min. Bland–Altman plots were used to study the agreement between IPAQ-SF and accelerometry-derived MET-min. Maximally acceptable limits of agreement were not defined a priori. Simple linear regressions were used to study the association that absolute bias showed with wear protocol (24 h protocol vs. waking-hour protocol) and patient characteristics [i.e. age, weight, height, body mass index, LVEF, categorical LVEF (HFmrEF vs. HFrEF), sex (males vs. females), aetiology (ischaemic vs. non-ischaemic), diabetes (i.e. yes vs. no), dyslipidaemia (i.e. yes vs. no), hypertension (i.e. yes vs. no)]. Regression coefficients represent the increase in absolute bias when the independent variable increases one unit. Subsequently, multiple linear regression analyses were performed for the variables that reached statistical significance in the previous simple linear regressions. On the other hand, the Kappa index was used to evaluate concordance between IPAQ-SF and accelerometry in classifying patients as active or non-active. Concordance was judged as follows: 0.00 to 0.20, poor; 0.21 to 0.40, low; 0.41 to 0.60, moderate; 0.61 to 0.80, good; and 0.81 to 1.00, excellent.47 Statistical significance was set at P ≤ 0.050. As a form of sensitivity analysis, all analyses were re-run using non-bouted MET-min (Appendix S8). STATA software (version 16.0; Stata Corp LLC, College Station, TX, USA) was used to carry out statistical analyses.
Results
Figure 1 shows the patient flow chart. Of the 82 patients with HF who were initially invited to participate, 61 were finally recruited, and 4 were excluded because completed assessments (i.e. IPAQ-SF and accelerometry) were not provided. Therefore, 57 patients completed the assessment, and 53 met accelerometry inclusion criteria.
[IMAGE OMITTED. SEE PDF]
Table 1 shows participants' characteristics. Walking was the only form of PA for 90% of the participants.
Table 1 Participant characteristics (
Variable | Frequency |
Age, years | 63.6 (9.9) [40–82] |
Weight, kg | 81.4 (19.3) [51.5–161.6] |
Height, cm | 168.0 (9.6) [149–183] |
BMI, kg/m2 | 28.7 (5.3) [18.7–50.4] |
LVEF, % | 34.7 (7.8) [15–49] |
LVEF | |
Mildly reduced | 17 (32.1) |
Reduced | 36 (67.9) |
Sex | |
Male | 38 (71.7) |
Female | 15 (28.3) |
NYHA functional class | |
I | 34 (64.1) |
II | 18 (34.0) |
III | 1 (1.9) |
Smoking | |
Current | 17 (32.1) |
Never smoker | 20 (37.7) |
Ex-smoker | 16 (30.2) |
Aetiology | |
Ischaemic | 23 (43.4) |
Non-ischaemic | 30 (56.6) |
Co-morbidities | |
Type 2 diabetes | 18 (34.0) |
Dyslipidaemia | 32 (60.4) |
Hypertension | 24 (45.3) |
Protocol | |
24 h | 28 (52.8) |
Waking-hour | 25 (47.2) |
IPAQ-SF score | |
Low | 13 (24.5) |
Moderate | 27 (51.0) |
High | 13 (24.5) |
IPAQ-SF weekly MVPA time (without walking) | |
Zero | 47 (88.7) |
Nonzero | 6 (11.3) |
Table 2 presents the correlations between IPAQ-SF and accelerometry-derived MET-min. The IPAQ-SF showed low correlation with Dibben et al.'s26 and Barnett et al.'s34 cut-points (ρ = 0.35 to 0.37), and negligible correlation with Troiano et al.'s,25 Mark et al.'s,30 Sanders et al.'s,36 and Vaha-Ypya et al.'s40 cut-points (ρ = 0.12 to 0.23).
Table 2 Spearman correlation analyses between International PA Questionnaire Short Form and accelerometry-derived MET-min, by cut-point
Mark et al.30a | Barnett et al.34a | Troiano et al.25a | Dibben et al.27 | Sanders et al.36 | Vaha-Ypya et al.40 | |
Spearman's rho (95% CI) | 0.22 (−0.05; 0.47) | 0.35 (0.08; 0.56) | 0.12 (−0.16; 0.38) | 0.37 (0.11; 0.58) | 0.20 (−0.08; 0.44) | 0.23 (−0.04; 0.47) |
Table 3 presents the median IPAQ-SF score and accelerometry-derived MET-min and the absolute bias between the two measures (IPAQ-SF vs accelerometry). The median absolute bias ranged from 691 to 1386 MET-min.
Table 3 Total weekly MET-min, by cut-point, and absolute bias
IPAQ | Mark et al.30a | Barnett et al.34a | Troiano, Berrigan et al.25a | Dibben et al.27 | Sanders et al.36 | Vaha-Ypya et al.40 | |
Total weekly MET-min | 1466 (693, 2892) | 372 (85, 870) | 442 (158, 1021) | 44 (0, 386) | 944 (156, 1873) | 166 (0, 560) | 329 (0, 884) |
Absolute bias (MET-min) | 1199 (279, 2357) | 1197 (158, 2077) | 1386 (462, 2713) | 691 (−357, 1678) | 1386 (414, 2354) | 1288 (301, 2135) |
Bland–Altman plots for IPAQ and accelerometry-derived MET-min based on the selected cut-points are shown in Figure 2.
[IMAGE OMITTED. SEE PDF]
Simple regression analyses showed statistically significant differences (P ≤ 0.050) only according to the protocol used, with each cut-point except for Dibben et al.27 Therefore, multiple linear regression analyses were not conducted. Regression analyses including the one variable that reached statistical significance (i.e. protocol) are shown in Table 4. Absolute bias was higher in participants following the waking-hour protocol (P ≤ 0.007). The remaining analyses can be found in Table S4 (Appendix S8).
Table 4 Significant results in the regression analysis, showing association between absolute bias and the protocol used (24 h vs. waking-hours)
Cut-points | Variable | (95% CI) | ||
Mark et al.30a | Protocol | 2496 | (1081; 3910) | 0.001* |
Barnett et al.34a | Protocol | 2184 | (760; 3607) | 0.003* |
Troiano et al.25a | Protocol | 2176 | (760; 3592) | 0.003* |
Sanders et al.36 | Protocol | 2027 | (602; 3453) | 0.006* |
Vaha-Ypya et al.40 | Protocol | 2021 | (588; 3454) | 0.007* |
The concordance between the two methods to classify patients as active and non-active following WHO PA recommendations39 is presented in Table 5. Low concordance was found when Mark et al.'s30 (κ = 0.23) and Barnett et al.'s34 (κ = 0.34) cut-points were used, while poor concordance was found for the remaining cut-points (κ = 0.03 to 0.18).
Table 5 Patient WHO PA classification, kappa index, and concordance between the accelerometry cut-points and IPAQ-SF
Cut-points | IPAQ | κ | Concordance | ||
Non-active | Active | ||||
Mark et al.30a | Non-active | 9 (18%) | 21 (40%) | 0.23 | Low |
Active | 1 (2%) | 21 (40%) | |||
Barnett et al.34a | Non-active | 10 (19%) | 18 (35%) | 0.34 | Low |
Active | 0 (0%) | 24 (46%) | |||
Troiano et al.25a | Non-active | 9 (18%) | 35 (67%) | 0.03 | Poor |
Active | 1 (2%) | 7 (13%) | |||
Dibben et al.27 | Non-active | 6 (11%) | 15 (28%) | 0.18 | Poor |
Active | 4 (8%) | 28 (53%) | |||
Sanders et al.36 | Non-active | 10 (19%) | 30 (56%) | 0.14 | Poor |
Active | 0 (0%) | 13 (25%) | |||
Vaha-Ypya et al.40 | Non-active | 10 (19%) | 27 (51%) | 0.18 | Poor |
Active | 0 (0%) | 16 (30%) |
The results of the sensitivity analysis using non-bouted MET-min are presented in the supplementary material (Appendix S8, Tables S4 to S7). The IPAQ showed low correlation with accelerometry-derived MET-min when using Dibben et al.'s,27 Mark et al.'s,30 Barnett et al.'s,34 Vaha-Ypya et al.'s40 cut-points (Table S5). Compared with the primary analysis, negative median absolute bias was found when Dibben et al.'s27 and Mark et al.'s30 cut-points were used (Table S6). Bland–Altman plots are shown in Figure S1. The results of the regression analyses were comparable with those of the primary analyses (Table S7). Concerning participants' classification following WHO PA recommendations, poor concordance was found, regardless of the cut-points used.
When assessing descriptive weekly time in MVPA using both methods (see Appendix S6, Table S2), participants reported a median of 0 min in IPAQ-SF excluding walking and 440 min including walking. In contrast, with accelerometry, we obtained a median range of 11 to 239 min. As for weekly walking time (see Appendix S7, Table S3), the results showed that participants reported a median of 420 min walking in IPAQ-SF, while participants spent 147 min at a cadence of over 60 steps/min (considered continuous walking or running) according to accelerometry. Of these 147 min, 98 min (67%) were performed at slow to medium walking cadence.
Discussion
The main findings of this study are as follows. (i) Correlations between IPAQ-SF and accelerometer measurements are poor (i.e. negligible or low) for all six cut-points used in this study. (ii) The device wear protocol may affect the absolute bias in most cut-points for accelerometry-based measures. (iii) There is no concordance between IPAQ-SF and accelerometers when classifying participants as active or non-active following WHO PA recommendations. (iv) The disparity between self-report and accelerometry-based measure of MVPA cannot be attributed to the IPAQ-SF data collection criteria (bouts of at least 10 min duration).
While the correlations between the IPAQ-SF and accelerometry were low, the highest correlation came about when applying cut-points calibrated to patients with the same traits (i.e. HF).27 In line with previous comparisons between IPAQ-SF and accelerometry conducted in HFpEF patients12 and other clinical populations,8,9,14,15 our data show lower PA by accelerometry compared with self-report, a disparity in PA measurements, and a lack of agreement between methods in patients with HFmrEF or HFrEF. Additionally, the Bland–Altman magnitude of the difference between the two methods was higher in more active patients. The lack of correlation and agreement between methods may be related to the different constructs measured by the two instruments. While accelerometry measures motion through acceleration of body mass above a defined threshold, the IPAQ-SF measures the time or perceived time spent performing specific behaviours.48 Therefore, the use of device-based measures of PA could contribute to avoiding bias in populations with limited physical function and limited knowledge and past experience of regular PA.49 Thus, in agreement with previous studies, our results support the use of accelerometry for measuring absolute intensity of PA in order to assess adherence to PA guidelines. Having said that, and despite the low correlation found, we encourage researchers to choose cut-points calibrated to the population studied.16,22 For acceleration metrics based on activity counts, Mark et al.'s30 cut-points seem to be the most appropriate, even though Freedson et al.'s24 are the most frequently used in studies with CVD and patients with HF.16,22 Similarly, for metrics based on mean amplitude deviation (MAD) and sum of vector magnitudes (SVM), we recommend Dibben et al.'s27 cut-points. Recently, researchers have published open-source alternatives like the GGIR package for processing raw accelerations to obtain different types of acceleration metrics (e.g. Euclidean norm minus one, MAD, and SVM). These tools facilitate the processing and extraction of data collected with several accelerometers, providing valuable insights on PA patterns.50 This alternative transfers the choice of signal processor from the manufacturer of the accelerometer to PA researchers.45
As for the influence of the patient's profile, our data suggest that the device wear protocol may affect the results when using most of the cut-points.27,30,34,36,40 This finding is attributable to a higher margin of error with the waking-hour versus 24 h protocol. Regarding the wear protocol, as most researchers agree,22 the 24 h protocol seems more appropriate even if only to monitor MVPA. Nonetheless, future studies are needed to analyse the influence of the 24 h versus waking-hour protocol.
When classifying participants as active or non-active following the latest WHO PA recommendations,39 regardless of the statistical correlation between the IPAQ-SF and different cut-points, an average of 46% of participants who were classified as non-active using accelerometry were considered active according to the IPAQ-SF, which confirms that the concordance between tools is suboptimal. Our results are more compelling but in line with a previous study in another clinical population,9 whose authors warned that using self-reported IPAQ-SF may misclassify patients with optimal PA, leading to sub-optimal disease management. Nonetheless, IPAQ-SF may still be useful for identifying how active patients are relative to other patients.8
Additionally, 90% of the participants reported that walking was their only form of PA. This outcome could partially explain the disparity of the results between methods. When assessing walking or running cadence in accelerometry, our results show that participants had a slow to medium walking cadence 67% of the time. Thus, caution is warranted when interpreting the walking as assessed by the IPAQ-SF in patients with HFmrEF or HFrEF. As walking and cycling pace were removed from both IPAQ-SF and IPAQ-LF,4 we could not assess this outcome in our study, but walking pace should be addressed in future studies that aim to investigate self-reported PA surveillance in patients with HF.
Lastly, investigating the effect of bouted versus non-bouted PA data, and contrary to the results of Schmidt et al.12 in patients with HFpEF, we observed a worse correlation when processing and analysing accelerometry data as non-bouted. This result contradicts the hypothesis that the poor correlation and non-equivalence between IPAQ and accelerometry data are attributable to patients' failure to consider 10-min bouts when self-reporting with the IPAQ-SF.
The main strength of our study is its novel approach; to our knowledge, there are no other studies comparing IPAQ-SF against different cut-points and accelerometer data processing approaches in a clinical population. Furthermore, as far as we know, there are no previous studies assessing correlation and agreement between IPAQ-SF versus accelerometry in patients with HFmrEF or HFrEF.
This study also has some limitations. Firstly, using two different protocols (i.e. 24 h vs waking-hour protocols) without randomized allocation limits intergroup comparability, and this may affect outcomes. Nonetheless, the two protocols were used, and the influence of the protocol on the difference between self-reported and device-based measurements was investigated. Secondly, due to sample size, adjustment for multiple testing has not been performed, and significant results have to be interpreted as exploratory due to a higher chance of false positive results. Thirdly, the IPAQ-SF does not distinguish between different intensities of walking (i.e. brisk walking = 4 MET); this bias was a limitation when transforming self-reported PA measurements from min to MET-min. Lastly, even though WHO PA guidelines are no longer presented in bouts, the IPAQ-SF still collects data in 10-min bouts.
In conclusion, given that high levels of PA in patients with HF have positive effects on HF prognostic indicators,19 accurate measurements are paramount for optimal clinical management. Although the IPAQ-SF has been commonly applied to monitor PA within clinical populations, MVPA measures using the IPAQ-SF and accelerometers are not equivalent, and we advise researchers against using the IPAQ-SF alone when assessing PA in patients with HFmrEF or HFrEF. Additionally, we cautiously support following the 24 h protocol and selecting cut-points calibrated to the CVD population.27,30 Finally, a new tailored questionnaire must be developed to consider walking intensity, in line with current WHO recommendations for PA, that is, collecting data on PA of any duration, without a minimum threshold.
Acknowledgements
TV was supported by the Cooperatio Program, research area Sport Sciences – Biomedical & Rehabilitation Medicine. We would like to thank Isabel Hernández, María Ajo, Raquel Ajo, and Ángela Carrillo for their support with the recruitment process and data collection.
Conflict of interest
None declared.
Funding
This research was funded by the Institute for Health and Biomedical Research of Alicante (ISABIAL, grant number 2020-0333) and by the Instituto de Salud Carlos III (ISCIII), co-funded by European Union. (ERDF, “A way to make Europe, grant number DTS21/00171).
Blasco‐Peris C, Fuertes‐Kenneally L, Vetrovsky T, Sarabia JM, Climent‐Paya V, Manresa‐Rocamora A. Effects of exergaming in patients with cardiovascular disease compared to conventional cardiac rehabilitation: A systematic review and meta‐analysis. Int J Environ Res Public Health 2022;19: [eLocator: 3492]. doi:
Kondamudi N, Haykowsky M, Forman DE, Berry JD, Pandey A. Exercise training for prevention and treatment of heart failure. Prog Cardiovasc Dis 2017;60:115–120. doi:
McDonagh TA, Metra M, Adamo M, Gardner RS, Baumbach A, Bohm M, et al. 2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J 2021;42:3599–3726. doi:
Craig CL, Marshall AL, Sjostrom M, Bauman AE, Booth ML, Ainsworth BE, et al. International physical activity questionnaire: 12‐country reliability and validity. Med Sci Sports Exerc 2003;35:1381–1395. doi:
Sallis JF, Bowles HR, Bauman A, Ainsworth BE, Bull FC, Craig CL, et al. Neighborhood environments and physical activity among adults in 11 countries. Am J Prev Med 2009;36:484–490. doi:
Sember V, Meh K, Soric M, Starc G, Rocha P, Jurak G. Validity and reliability of international physical activity questionnaires for adults across EU countries: systematic review and meta analysis. Int J Environ Res Public Health 2020;17:23. doi:
Benitez‐Porres J, Delgado M, Ruiz JR. Comparison of physical activity estimates using international physical activity questionnaire (IPAQ) and accelerometry in fibromyalgia patients: The Al‐Andalus study. J Sports Sci 2013;31:1741–1752. doi:
Firth J, Stubbs B, Vancampfort D, Schuch FB, Rosenbaum S, Ward PB, et al. The validity and value of self‐reported physical activity and Accelerometry in people with schizophrenia: A population‐ scale study of the UK biobank. Schizophr Bull 2018;44:1293–1300. doi:
Joseph KL, Dagfinrud H, Christie A, Hagen KB, Tveter AT. Criterion validity of the international physical activity questionnaire‐short form (IPAQ‐SF) for use in clinical practice in patients with osteoarthritis. BMC Musculoskelet Disord 2021;22:9. doi:
Krueger T, Behrens JR, Grobelny A, Otte K, Mansow‐Model S, Kayser B, et al. Subjective and objective assessment of physical activity in multiple sclerosis and their relation to health‐related quality of life. Bmc. Neurology 2017;17:10. doi:
Rosa CSD, Gracia‐Marco L, Barker AR, Freitas IF, Monteiro HL. Assessment of physical activity by accelerometer and IPAQ‐short version in patients with chronic kidney disease undergoing hemodialysis. Blood Purif 2015;40:250–255. doi:
Schmidt C, Santos M, Bohn L, Delgado BM, Moreira‐Goncalves D, Leite‐Moreira A, et al. Comparison of questionnaire and accelerometer‐based assessments of physical activity in patients with heart failure with preserved ejection fraction: Clinical and prognostic implications. Scand Cardiovasc J 2020;54:77–83. doi:
Stavropoulos‐Kalinoglou A, Metsios GS, Smith JP, Panoulas VF, Douglas KMJ, Jamurtas AZ, et al. What predicts obesity in patients with rheumatoid arthritis? An investigation of the interactions between lifestyle and inflammation. Int J Obes (Lond) 2010;34:295–301. doi:
Vassbakk‐Brovold K, Kersten C, Fegran L, Mjaland O, Mjaland S, Seiler S, et al. Cancer patients participating in a lifestyle intervention during chemotherapy greatly over‐report their physical activity level: A validation study. BMC Sports Sci Med Rehabil 2016;8:9. doi:
Veitch WG, Climie RE, Gabbe BJ, Dunstan DW, Owen N, Ekegren CL. Agreement between the international physical activity questionnaire and accelerometry in adults with orthopaedic injury. Int J Environ Res Public Health 2020;17:13. doi:
Klompstra L, Kyriakou M, Lambrinou E, Piepoli MF, Coats AJS, Cohen‐Solal A, et al. Measuring physical activity with activity monitors in patients with heart failure: From literature to practice. A position paper from the Committee on Exercise Physiology and Training of the Heart Failure Association of the European Society of Cardiology. Eur J Heart Fail 2021;23:83–91. doi:
Sylvia LG, Bernstein EE, Hubbard JL, Keating L, Anderson EJ. Practical guide to measuring physical activity. J Acad Nutr Diet 2014;114:199–208. doi:
Limb ES, Ahmad S, Cook DG, Kerry SM, Ekelund U, Whincup PH, et al. Measuring change in trials of physical activity interventions: A comparison of self‐report questionnaire and accelerometry within the PACE‐UP trial. Int J Behav Nutr Phys Act 2019;16:10. doi:
Shoemaker MJ, Mattern M, Scholten H, Zeitler J, Gore S. Subjective daily physical activity measures in heart disease: A systematic review. J Phys Act Health 2021;18:450–460. doi:
Stelmach M. Physical activity assessment tools in monitoring physical activity: The global physical activity questionnaire (GPAQ), the international physical activity questionnaire (IPAQ) or accelerometers ‐ choosing the best tools. Health Problems Civilization 2018;12:57–63. doi:
Migueles JH, Cadenas‐Sanchez C, Tudor‐Locke C, Lof M, Esteban‐Cornejo I, Molina‐Garcia P, et al. Comparability of published cut‐points for the assessment of physical activity: Implications for data harmonization. Scand J Med Sci Sports 2019;29:566–574. doi:
Vetrovsky T, Clark CCT, Bisi MC, Siranec M, Linhart A, Tufano JJ, et al. Advances in accelerometry for cardiovascular patients: A systematic review with practical recommendations. Esc Heart Failure 2020;7:2021–2031. doi:
Kim Y, Beets MW, Welk GJ. Everything you wanted to know about selecting the "right" Actigraph accelerometer cut‐points for youth, but …: A systematic review. J Sci Med Sport 2012;15:311–321. doi:
Freedson PS, Melanson E, Sirard J. Calibration of the computer science and applications, Inc accelerometer. Med Sci Sports Exerc 1998;30:777–781. doi:
Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M. Physical activity in the United States measured by accelerometer. Med Sci Sports Exerc 2008;40:181–188. doi:
Dibben GO, Hillsdon M, Dalal HM, Tang LH, Doherty PJ, Taylor R. Home‐based cardiac rehabilitation and physical activity in people with heart failure: A secondary analysis of the REACH‐HF randomised controlled trials. BMJ Open 2023;13: [eLocator: e063284]. doi:
Dibben GO, Gandhi MM, Taylor R, Dalal HM, Metcalf B, Doherty P, et al. Physical activity assessment by accelerometry in people with heart failure. BMC Sports Sci Med Rehabil 2020;12:47. doi:
Santos‐Lozano A, Santin‐Medeiros F, Cardon G, Torres‐Luque G, Bailon R, Bergmeir C, et al. Actigraph GT3X: Validation and determination of physical activity intensity cut points. Int J Sports Med 2013;34:975–982. doi:
Prince SA, Reed JL, Mark AE, Blanchard CM, Grace SL, Reid RD. A comparison of accelerometer cut‐points among individuals with coronary artery disease. PLoS ONE 2015;10:12. doi:
Mark AE, Prince SA, Reed JL, Reid RD. Actigraph GT3X+ cut points in coronary artery disease patients: A pilot study. Health Fitness J Can 2015;8:13–21. doi:
Barker J, Byrne KS, Doherty A, Foster C, Rahimi K, Ramakrishnan R, et al. Physical activity of UK adults with chronic disease: Cross‐sectional analysis of accelerometer‐measured physical activity in 96 706 UK biobank participants. Int J Epidemiol 2019;48:1167–1174. doi:
Hildebrand M, Van Hees VT, Hansen BH, Ekelund U. Age group comparability of raw accelerometer output from wrist‐ and hip‐worn monitors. Med Sci Sports Exerc 2014;46:1816–1824. doi:
Jonsson M, Westerdahl E, Ahlsson A, Hurtig‐Wennlof A. Validation of two self‐reported physical activity instruments against accelerometer data in patients undergoing lung cancer surgery. Physiother Theory Pract 2022;38:3119–3125. doi:
Barnett A, van den Hoek D, Barnett D, Cerin E. Measuring moderate‐intensity walking in older adults using the ActiGraph accelerometer. Bmc. Geriatrics 2016;16:211. doi:
Subias‐Perie J, Navarrete‐Villanueva D, Fernandez‐Garcia AI, Moradell A, Gesteiro E, Perez‐Gomez J, et al. Prevalence of metabolic syndrome and association with physical activity and frailty status in Spanish older adults with decreased functional capacity: a cross‐sectional study. Nutrients 2022;14: [eLocator: 2302]. doi:
Sanders GJ, Boddy LM, Sparks SA, Curry WB, Roe B, Kaehne A, et al. Evaluation of wrist and hip sedentary behaviour and moderate‐to‐vigorous physical activity raw acceleration cutpoints in older adults. J Sports Sci 2019;37:1270–1279. doi:
O'Donnell J, Smith‐Byrne K, Velardo C, Conrad N, Salimi‐Khorshidi G, Doherty A, et al. Self‐reported and objectively measured physical activity in people with and without chronic heart failure: UK biobank analysis. Open Heart 2020;7:7. doi:
Lang RM, Badano LP, Mor‐Avi V, Afilalo J, Armstrong A, Ernande L, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J‐Cardiovasc Imaging 2015;16:233–271. doi:
WHO. World Health Organization. Guidelines on physical activity and sedentary behaviour. 2020.
Vaha‐Ypya H, Vasankari T, Husu P, Manttarl A, Vuorimaa T, Suni J, et al. Validation of cut‐points for evaluating the intensity of physical activity with Accelerometry‐based mean amplitude deviation (MAD). PLoS ONE 2015;10: [eLocator: e0134813]. doi:
Tudor‐Locke C, Ducharme SW, Aguiar EJ, Schuna JM, Barreira TV, Moore CC, et al. Walking cadence (steps/min) and intensity in 41 to 60‐year‐old adults: The CADENCE‐adults study. Int J Behav Nutr Phys Act 2020;17:137. doi:
Tudor‐Locke C, Han H, Aguiar EJ, Barreira TV, Schuna JM, Kang M, et al. How fast is fast enough? Walking cadence (steps/min) as a practical estimate of intensity in adults: A narrative review. Br J Sports Med 2018;52:776–788. doi:
Migueles JH, Cadenas‐Sanchez C, Ekelund U, Nystrom CD, Mora‐Gonzalez J, Lof M, et al. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: A systematic review and practical considerations. Sports Med 2017;47:1821–1845. doi:
Choi L, Liu ZW, Matthews CE, Buchowski MS. Validation of accelerometer wear and nonwear time classification algorithm. Med Sci Sports Exerc 2011;43:357–364. doi:
van Hees VT, Gorzelniak L, Leon ECD, Eder M, Pias M, Taherian S, et al. Separating movement and gravity components in an acceleration signal and implications for the assessment of human daily physical activity. PLoS ONE 2013;8: [eLocator: e61691]. doi:
Wolff‐Hughes DL, Fitzhugh EC, Bassett DR, Churilla JR. Total activity counts and bouted minutes of moderate‐to‐vigorous physical activity: Relationships with cardiometabolic biomarkers using 2003‐2006 NHANES. J Phys Act Health 2015;12:694–700. doi:
Altman D. Practical statistics for medical research. London: Chapman and Hall; 1991:1–611.
Troiano RP, McClain JJ, Brychta RJ, Chen KY. Evolution of accelerometer methods for physical activity research. Br J Sports Med 2014;48:1019–1023. doi:
Prince SA, Adamo KB, Hamel ME, Hardt J, Gorber SC, Tremblay M. A comparison of direct versus self‐report measures for assessing physical activity in adults: A systematic review. Int J Behav Nutr Phys Act 2008;5: [eLocator: 56]. doi:
Migueles JH, Rowlands AV, Huber H, Sabia S, van Hees VT. GGIR: A research community–driven open source R package for generating physical activity and sleep outcomes from multi‐day raw accelerometer data. J Meas Phys Behav 2019;2:188–196. doi:
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2024. This work is published under http://creativecommons.org/licenses/by-nc-nd/4.0/ (the "License"). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Aims
Physical activity (PA) is an important target for improving clinical outcomes in heart failure (HF) patients. Nonetheless, assessing the daily PA profile in this population is a challenging task, traditionally performed using self‐report questionnaires such as the International PA Questionnaire Short Form (IPAQ‐SF). This study aimed to evaluate the concurrent validity of the IPAQ‐SF and accelerometer‐assessed PA using six published cut‐points in patients with HF and reduced or mildly reduced ejection fraction.
Methods and results
The concordance between the IPAQ‐SF and a hip‐worn accelerometer regarding daily time spent performing moderate to vigorous PA in bouts of at least 10 min was assessed in 53 participants for seven consecutive days using six different cut‐points (Barnett, Dibben, Mark, Sanders, Troiano, and Vaha‐Ypya). Spearman's correlation and Bland–Altman plots were used to evaluate concurrent validity between methods. Regressions were used to study the association between patient variables, wear protocol (waking hour or 24 h), and absolute bias. The kappa index was used to evaluate the concordance between IPAQ‐SF and accelerometry for classifying patients as active or non‐active. All analyses were re‐run using non‐bouted metrics to investigate the effect of bouted versus non‐bouted analysis. The IPAQ‐SF and accelerometry showed low to negligible correlation (ρ = 0.12 to 0.37), depending on the cut‐point used. The regression analysis showed that the absolute bias was higher in participants following the waking‐hour protocol at all cut‐points except Dibben's (P ≤ 0.007). The concordance between the two methods to classify patients as active and non‐active was low when using Mark (κ = 0.23) and Barnett (κ = 0.34) cut‐points and poor for the remaining cut‐points (κ = 0.03 to 0.18). The results of the sensitivity analysis showed negligible to low correlation using non‐bouted metrics (ρ = 0.27 to 0.33).
Conclusions
Moderate to vigorous PA measures using IPAQ‐SF and accelerometers are not equivalent, and we do not encourage researchers to use IPAQ‐SF alone when assessing PA in HF patients. Moreover, applying personalized collection and processing criteria is important when assessing PA in HF patients. We recommend following the 24 h protocol and selecting cut‐points calibrated in patients with cardiovascular diseases. Finally, it is necessary to develop a new tailored questionnaire that considers walking intensity and is adjusted to the current World Health Organisation recommendations, which use non‐bouted metrics.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details







1 Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain, Department of Physical Education and Sport, University of Valencia, Valencia, Spain
2 Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain, Department of Cardiology, Dr Balmis General University Hospital (HGUA), Alicante, Spain
3 Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic
4 Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain, Department of Sport Sciences, Sports Research Centre, Miguel Hernández University of Elche, Elche, Spain
5 Department of Sport Sciences, Sports Research Centre, Miguel Hernández University of Elche, Elche, Spain