Full text

Turn on search term navigation

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Respiratory rate (RR) is a critical vital sign that can provide valuable insights into various medical conditions, including pneumonia. Unfortunately, manual RR counting is often unreliable and discontinuous. Current RR estimation algorithms either lack the necessary accuracy or demand extensive window sizes. In response to these challenges, this study introduces a novel method for continuously estimating RR from photoplethysmogram (PPG) with a reduced window size and lower processing requirements. To evaluate and compare classical and deep learning algorithms, this study leverages the BIDMC and CapnoBase datasets, employing the Respiratory Rate Estimation (RRest) toolbox. The optimal classical techniques combination on the BIDMC datasets achieves a mean absolute error (MAE) of 1.9 breaths/min. Additionally, the developed neural network model utilises convolutional and long short-term memory layers to estimate RR effectively. The best-performing model, with a 50% train–test split and a window size of 7 s, achieves an MAE of 2 breaths/min. Furthermore, compared to other deep learning algorithms with window sizes of 16, 32, and 64 s, this study’s model demonstrates superior performance with a smaller window size. The study suggests that further research into more precise signal processing techniques may enhance RR estimation from PPG signals.

Details

Title
A Novel Respiratory Rate Estimation Algorithm from Photoplethysmogram Using Deep Learning Model
Author
Wee, Jian Chin 1 ; Ban-Hoe Kwan 1   VIAFID ORCID Logo  ; Wei Yin Lim 2   VIAFID ORCID Logo  ; Yee, Kai Tee 1   VIAFID ORCID Logo  ; Darmaraju, Shalini 3 ; Liu, Haipeng 4   VIAFID ORCID Logo  ; Choon-Hian Goh 1   VIAFID ORCID Logo 

 Department of Mechatronics and Biomedical Engineering, Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang 43000, Selangor, Malaysia; [email protected] (W.J.C.); [email protected] (B.-H.K.); [email protected] (Y.K.T.); [email protected] (S.D.); Centre for Healthcare Science and Technology, Universiti Tunku Abdul Rahman, Kajang 43000, Selangor, Malaysia 
 Electrical and Computer Systems Engineering, School of Engineering and Advanced Engineering Platform, Monash University Malaysia, Bandar Sunway 47500, Selangor, Malaysia; [email protected] 
 Department of Mechatronics and Biomedical Engineering, Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Kajang 43000, Selangor, Malaysia; [email protected] (W.J.C.); [email protected] (B.-H.K.); [email protected] (Y.K.T.); [email protected] (S.D.) 
 Centre for Intelligent Healthcare, Coventry University, Coventry CV1 5RW, UK; [email protected] 
First page
284
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
20754418
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2923901564
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.