Abstract
Background
Performing a surgical task subjects the surgeon to multitudinal stressors, especially with the newer 3D technology. The quantum of cognitive workload using this modern surgical system in comparison to the Conventional microscope system remains unexplored. We evaluate the surgeon’s cognitive workload and the surgical outcomes of macular hole(MH) surgery performed on a 3D versus a Conventional microscope operating system.
Methods
50 eyes of 50 patients with MH undergoing surgery using the 3D or Conventional microscope visualization system. Cognitive workload assessment was done by real-time tools(Surgeons’ heart rate [HR] and oxygen saturation[SPO2]) and self-report tool(Surgery Task Load Index[SURG-TLX] questionnaire) of three Vitreoretinal surgeons. Based on the SURG-TLX questionnaire, an assessment of the workload was performed.
Results
Of the 50 eyes, 30 eyes and 20 eyes underwent surgery with the Conventional microscope and the 3D system, respectively. No difference was noted in the MH basal-diameter(p = 0.128), total surgical-duration(p = 0.299), internal-limiting membrane(ILM) peel time(p = 0.682), and the final visual acuity (VA; p = 0.515) between the two groups. Both groups showed significant improvement in VA(p < 0.001) with a 90% closure rate at one-month post-surgery. Cognitive workload comparison, the intraoperative HR(p = 0.024), total workload score(P = 0.005), and temporal-demand dimension(p = 0.004) were significantly more in Conventional microscope group as compared to 3D group. In both the groups, the HR increased significantly from the baseline while performing ILM peeling and at the end.
Conclusion
The surgeon’s cognitive workload is markedly reduced while performing macular hole surgery with a 3D viewing system. Moreover, duration of surgery including ILM peel time, MH closure rates, and visual outcomes remains unaffected irrespective of the operating microscope system.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer