Full Text

Turn on search term navigation

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Heart failure, a common clinical syndrome caused by functional and structural abnormalities of the heart, affects 64 million people worldwide. Long-term mechanical circulatory support can offer lifesaving treatment for end-stage systolic heart failure patients. However, this treatment is not without complications. This review covers the major complications associated with implantable mechanical circulatory support devices, including strokes, pump thrombosis and gastrointestinal bleeding. These complications were assessed in patients implanted with the following devices: Novacor, HeartMate XVE, CardioWest, Jarvik 2000, HeartMate II, EVAHEART, Incor, VentrAssist, HVAD and HeartMate 3. Complication rates vary among devices and remain despite the introduction of more advanced technology, highlighting the importance of device design and flow patterns. Beyond clinical implications, the cost of complications was explored, highlighting the difference in costs and the need for equitable healthcare, especially with the expected rise in the use of mechanical circulatory support. Future directions include continued improvement through advancements in design and technology to reduce blood stagnation and mitigate high levels of shear stress. Ultimately, these alterations can reduce complications and enhance cost-effectiveness, enhancing both the survival and quality of life for patients receiving mechanical circulatory support.

Details

Title
The Evolution and Complications of Long-Term Mechanical Circulatory Support Devices
Author
Sargent, Christian R 1 ; Ali, Sabrina 1 ; Venkateswarlu Kanamarlapudi 2   VIAFID ORCID Logo 

 Calon Cardio Technology Ltd., ILS II, Swansea University, Swansea SA2 8PP, UK; [email protected] 
 Singleton Park Campus, Swansea University Medical School, ILS I, Swansea SA2 8PP, UK; [email protected] 
First page
105
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
26733846
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3002000590
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.