Introduction
Although the incidence of spontaneous intracerebral hemorrhage is lower than that of ischemic stroke, it results in more severe neurological damage, higher mortality rates, and poorer prognoses [1]. Recent advancements in surgical instruments and techniques have created conditions conducive to precise minimally invasive puncture surgery for treating spontaneous intracerebral hemorrhage. While the STICH trials [2,3] suggested that surgery did not lead to a better prognosis for patients, findings from the MISTIE trials [4–6] suggested that minimally invasive surgery improved functional outcomes for patients with a residual hematoma volume of 15 ml or less. The latest ENRICH trial [7] was the first to indicate that surgical removal of intracerebral hematoma within 24 hours of symptom onset could enhance functional outcomes in patients with spontaneous intracerebral hemorrhage. Consequently, early reduction of hematoma volume may play an important role in enhancing the efficacy of surgical interventions.
Intra-hematoma injection of thrombolytic drugs, such as alteplase or urokinase, has become a widely employed clinical treatment for patients with spontaneous intracerebral hemorrhage [1]. However, the effectiveness of hematoma lysis solely through the injection of thrombolytic drugs is limited due to the localized diffusion around the drainage tube tip and the constraints imposed by the indwelling time, volume, and frequency of drug injections. In the MISTIE III trial [6], the proportion of postoperative residual hematoma volumes > 15 ml was 43% (108/250), indicating the need to address the challenge of accelerating hematoma lysis to facilitate drainage.
The combined use of ultrasound with thrombolytic drugs has shown significant efficacy in clinical applications such as middle cerebral artery thrombosis, peripheral deep vein thrombosis, and pulmonary artery thrombosis [8–11]. However, it remains unknown whether this combination can enhance intracerebral hematoma lysis in patients with spontaneous intracerebral hemorrhage. In an in vitro experiment [12], researchers implanted an endosonography probe into blood clots in vitro and found that ultrasound combined with thrombolytic drugs dissolved clots more effectively compared with the use of ultrasound or thrombolytic drugs alone. However, the placement of an ultrasound probe into the cerebrum is invasive [13]. If extracorporeal ultrasound proves effective in enhancing intracerebral hematoma lysis, it could significantly strengthen its clinical utility.
Conventional transcranial ultrasound is impeded by the skull, resulting in a substantial loss of ultrasound energy [14]. Considering these challenges and the need for surgical feasibility, we developed an experimental device (Fig 1) based on a key-shaped bone window, as per previous studies [12,13,15,16]. This device simulated minimally invasive puncture and drainage surgery for spontaneous intracerebral hemorrhage, while using ultrasound to irradiate the blood clot (Fig 2). The objective of this study is to investigate the feasibility of using ultrasound combined with urokinase to enhance blood clot lysis in vitro.
[Figure omitted. See PDF.]
The 37°C thermostatic water bath simulates the cranial cavity in Fig 2, with the white, key-shaped defect area of the lid of the water bath representing the key-shaped bone window of the skull in Fig 2B, and the red balloon simulating the intracerebral hematoma. The complete set of experimental devices simulates the puncture and drainage of the intracerebral hematoma and continuous ultrasound irradiation of the hematoma, as shown in Fig 2C.
[Figure omitted. See PDF.]
(a) Surgical incision. (b) Scalp pulled back and a key-shaped bone window cut into the skull (The key-shaped bone window consists of two parts: The bone pore and the bone gap. The diameter of the bone pore is 1.5 cm, determined by the surgical drill size. The width of the bone gap is > 0.5 mm, determined by the ultrasonic wavelength. The length of the bone gap can be adjusted according to the sagittal diameter of the hematoma.). (c) Hematoma punctured, drainage tube placed, and continuous ultrasound irradiation applies through the key-shaped bone window.
Materials and methods
Experimental equipment
The following experimental equipment was used in this study. The color ultrasound diagnostic system (Wisonic Clivia 90, Shenzhen Huasheng Medical Technology Co., Ltd., China): pulsed-wave mode, frequency (4.5 MHz), power (91 mW), mechanical index (1.8) and duration (1 hour). Thermostatic water bath (JOANLAB, model BHS, China). Temperature measuring instrument (YOWEXA, model YET-620L, China). Scale (KTURE high-precision scale, China). Drainage tube (Weihai Chuangshi Medical Technology Co., Ltd., model NSYL-II [external diameter 4 mm, 2 side holes], China).
Preparation and grouping of blood clots
Following previous studies [17,18], a solution of 600 μl 5% calcium chloride (Xiamen Haibiao Technology Co., Ltd., China) was combined with 30 ml of fresh sterile anticoagulant bovine whole blood (Zhengzhou Pingrui Biotechnology Co., Ltd., China) in a balloon. The mixture was thoroughly blended, and the balloon was securely sealed using sutures after completion. Subsequently, the sealed balloon was immersed in a 37°C thermostatic water bath, with its center positioned 8 cm from the water surface. The incubation period lasted for 3 hours to facilitate the formation of a stable blood clot (Fig 3).
[Figure omitted. See PDF.]
The smallest scale on the ruler is 0.5mm. (a) Formation of a blood clot inside a balloon. (b) Median dissection of the blood clot.
With reference to previous literature [15] (residual hematoma weight as the main outcome), the sample size was calculated using PASS 15.0 software to be 16 (power = 90%, α = 0.05, dropout rate = 20%). However, since our study was an exploratory experiment, and considering the differences between our experimental methods and the reference, we set the sample size to 40.
A total of 40 blood clots were prepared using the methods described above. The blood clots were then categorized into four groups—control group, ultrasound group, urokinase group, and ultrasound + urokinase group—based on the random number table method. Each group consisted of 10 blood clots.
Medications for injection
Urokinase (Wuhan Renfu Pharmaceutical Co., Ltd., 100,000 IU, China) was prepared into a solution with 10,000 IU/ml using normal saline (Southwest Pharmaceutical Co., Ltd., 0.9% concentration, China). The prepared solution was stored in a 5°C refrigerator, and it was reformulated if kept for more than 24 hours. For the control and ultrasound groups, 3 ml of normal saline was injected. In the urokinase group and ultrasound + urokinase group, 20,000 IU of urokinase was injected, followed by flushing the tube with 1 ml of normal saline (the drainage tube’s cavity volume was 1 ml). The volume of the transcatheter injection solution into each blood clot was standardized to 3 ml.
Experimental procedure
Following the preparation of the blood clot, the balloon containing the blood clot was weighed to determine the pre-treatment weight, after removing surface water from the balloon. The balloon was then securely ligated with sutures after placing a drainage tube at the center of the blood clot. Subsequently, the balloon was positioned in a 37°C thermostatic water bath, with the center of the blood clot situated 8 cm under the water surface. This arrangement aimed to simulate the distance between the scalp and the intracerebral hematoma in the basal ganglia on the sagittal plane. The other end of the drainage tube was connected to a drainage bag, positioned 20 cm below the blood clot, allowing gravity to facilitate the drainage of the liquefied blood clot (Fig 1).
For the control group, a volume of 3 ml normal saline was injected into the blood clot through a three-way valve, and the valve was closed for a duration of 1 hour. In the ultrasound group, a similar volume of normal saline was injected into the blood clot through the three-way valve, the valve was then closed, and the tip of the drainage tube was positioned through the key-shaped bone window using ultrasound, followed by continuous irradiation for 1 hour. In the urokinase group, 20,000 IU of urokinase was initially injected into the blood clot through the three-way valve, followed by the injection of 1 ml of normal saline to flush the drainage tube. The three-way valve was closed for 1 hour. In the ultrasound + urokinase group, 20,000 IU of urokinase was injected into the blood clot through the three-way valve, followed by 1 ml of normal saline to flush the drainage tube. The three-way valve was then closed, and the tip of the drainage tube was positioned through the key-shaped bone window using ultrasound, with continuous irradiation for 1 hour (Fig 4).
[Figure omitted. See PDF.]
The smallest scale on the ruler is 5mm.
After the above treatments, the three-way valve was opened to drain the liquefied blood clot in all experimental groups. The valve was closed after continuous drainage for 1 hour. The drainage tube and sutures were removed, and any remaining water on the balloon’s surface was dried with absorbent paper. The balloon and the residual blood clot were then weighed to obtain the post-treatment weight.
Blood clot lysis rate was calculated using the formula: Blood clot lysis rate = (pre-treatment weight—post-treatment weight) / (pre-treatment weight—balloon weight) x 100%. Pre-treatment weight: this was determined after the formation of the blood clot. The weight of the balloon and the blood clot was measured after removing surface water from the balloon using absorbent paper. Post-treatment weight: after the experiment, the drainage tube and suture were removed, and any water on the surface of the balloon was removed with absorbent paper. The weight of the balloon and the residual blood clot was then measured.
Key-shaped bone window: the key-shaped bone window consists of two parts: the bone pore and the bone gap (Fig 2B). The diameter of the bone pore was 1.5 cm, determined by the surgical drill size. The width of the bone gap was > 0.5 mm, determined by the ultrasonic wavelength. The length of the bone gap can be adjusted according to the sagittal diameter of the hematoma.
Temperature measurement in the ultrasound + urokinase group
In the Ultrasound + Urokinase group, the temperature of the balloon surface and at distances of 2 cm, 4 cm, 6 cm, 8 cm, and 10 cm away from the balloon surface was recorded using a temperature measuring instrument. Measurements were taken at 10-minute intervals starting from the initiation of ultrasound irradiation.
Statistical analysis
Continuous variables were presented as mean ± standard deviation (SD). Group comparisons were executed using one-way analysis of variance (ANOVA) or two-way repeated measures ANOVA for continuous variables. Post-hoc multiple comparisons were adjusted using the Bonferroni method to account for potential Type I errors. All statistical tests were two-tailed, and a significance level of P < 0.05 was adopted for determining statistical significance. Statistical analyses were carried out utilizing SPSS 25.0 (IBM).
Results
Blood clot lysis rate
A total of 40 blood clots were observed, with 10 in each experimental group. The pre-treatment weights of blood clots in the control group, ultrasound group, urokinase group, and ultrasound + urokinase group were 31.05 ± 0.28 g, 31.15 ± 0.32 g, 31.34 ± 0.47 g, and 31.14 ± 0.40 g, respectively. No significant difference in the pre-treatment weight of blood clots was observed among the four groups (p = 0.381).
Post-treatment, the blood clot lysis rate in the ultrasound group, urokinase group, and ultrasound + urokinase group (24.83 ± 4.67%, 47.85 ± 7.09%, 61.13 ± 4.06%) was significantly higher compared to the control group (16.11 ± 3.42%) (p = 0.002, p < 0.001, p < 0.001). Moreover, the blood clot lysis rate in the ultrasound + urokinase group (61.13 ± 4.06%) was significantly higher than that in the ultrasound group (24.83 ± 4.67%) (p < 0.001) or urokinase group (47.85 ± 7.09%) (p < 0.001).
Temperature variation in the ultrasound + urokinase group
During the one hour of ultrasound irradiation, the temperature of the balloon surface and within a 10 cm vicinity was measured at different time points. The average temperature increase was 0.26 ± 0.15°C, with a minimum of 0.18 ± 0.13°C and a maximum of 0.38 ± 0.09°C.
The analysis utilizing two-way repeated measures ANOVA revealed no significant difference in temperature increase concerning the main effect of time interval (F = 0.705, p = 0.620), the main effect of distance (F = 0.788, p = 0.563), or the multiplication interaction of time interval and distance (F = 1.100, p = 0.342) (Table 1).
[Figure omitted. See PDF.]
Discussion
This study simulated minimally invasive puncture surgery in patients with spontaneous intracerebral hemorrhage. The observed blood clot lysis rates in the ultrasound group, urokinase group, and ultrasound + urokinase group (24.83 ± 4.67%, 47.85 ± 7.09%, 61.13 ± 4.06%) were significantly higher than those in the control group (16.11 ± 3.42%) (p = 0.002, p < 0.001, p < 0.001). Moreover, the blood clot lysis rate in the ultrasound + urokinase group (61.13 ± 4.06%) was markedly higher compared to the ultrasound group (24.83 ± 4.67%) (p < 0.001) or the urokinase group (47.85 ± 7.09%) (p < 0.001). In the ultrasound + urokinase group, the observed mean increase in temperature around the blood clot was 0.26 ± 0.15°C, with a maximum increase of 0.38 ± 0.09°C. Importantly, there was no statistically significant difference in the temperature increase concerning the main effect of time interval (F = 0.705, p = 0.620), the main effect of distance (F = 0.788, p = 0.563), or the multiplication interaction between time interval and distance (F = 1.100, p = 0.342).
The widely accepted mechanism of sonothrombolysis involves acoustic radiation pressure and ultrasound-induced stable cavitation and inertial cavitation. These processes generate microflow and microjets, leading to the temporary release of the fibrin clot. This phenomenon serves to enhance the diffusion of thrombolytic drugs within the blood clot, ultimately improving the therapeutic efficacy of thrombolytic agents. The synergistic effect of ultrasound contributes to faster and more effective thrombolysis. These mechanisms indicate the potential of ultrasound as a valuable adjunct to thrombolytic therapy [19–24].
In peripheral blood vessels, sonothrombolysis had been demonstrated to be both safe and effective. A meta-analysis focused on peripheral deep vein thrombosis encompassed 18 studies with a total of 597 patients [10]. The overall success rate of ultrasound-accelerated catheter-directed thrombolysis (USACDT) in patients with deep vein thrombosis was 87.8% (18 studies, 95% confidence interval [CI]: 83.1–91.3). Notably, the success rate of USACDT was significantly higher than that of conventional catheter thrombolysis (7 studies, odds ratio [OR]: 2.96, 95% CI: 1.69–5.16, P < 0.01). Importantly, there was no significant difference in the total complication rates between the two treatments.
In a case report [11] discussing pulmonary embolism, ultrasonographic accelerated thrombolytic therapy was employed in three patients with acute pulmonary embolism who had contraindications to systemic thrombolysis. All three patients exhibited significant clinical and hemodynamic improvements in the short term, achieving thrombolysis and rapid decreases in systolic and mean pulmonary artery pressure.
Numerous clinical studies had explored the role of ultrasound in promoting the lysis of intracranial arterial thrombosis. In a meta-analysis of acute ischemic stroke encompassing seven randomized controlled clinical trials [9], patients diagnosed with large vessel occlusion were randomly assigned to either an ultrasound thrombolysis group (138 cases) or an intravenous thrombolysis alone group (134 cases). The probability of complete recanalization was found to be increased in the ultrasound group (40.3% vs. 22.4%, Adjusted OR: 2.33, 95% CI: 1.02–5.34). Importantly, there was no significant difference in intracranial hemorrhage between the two groups. These findings provided a safe and feasible basis for the clinical application of ultrasound in dissolving both peripheral and intracranial intravascular thrombosis.
The use of ultrasound for the assisted lysis of intracerebral hematoma is infrequently reported and is primarily limited to in vitro studies. In one such in vitro study [13], human blood clots (volume: 25 ml) were categorized into six different treatment groups: control group, alteplase group, one doppler probe group, two doppler probes group, one doppler probe + alteplase group, and two doppler probes + alteplase group. Notably, the group with two doppler probes plus alteplase achieved the most effective blood clot lysis (36.3 ± 4.4%). Temperature measurements were taken at distances of 0–7 cm from the ultrasound probe, revealing a maximum temperature increase of 0.17 ± 0.07°C. The authors pointed out that the radiation of ultrasound energy was significantly reduced in the presence of the skull. Although bilateral transcranial Doppler (TCD) can improve the attenuation of ultrasound energy by the skull, challenges remain in accurately placing two TCD probes completely opposite each other and precisely locating the hematoma with the TCD probe.
To address these challenges, we designed a key-shaped bone window for use in clinical minimally invasive surgery. This design allowed for implementation under a straight scalp incision, effectively mitigating the influence of the skull on ultrasound. Importantly, the dura was not opened after cutting the key-shaped bone window in the skull, minimizing damage to brain tissue. Ultrasound images can accurately locate the hematoma, enhancing clinical applicability. While the maximum temperature increase in this study was higher than that reported in previous studies, the observed temperature increase range in this study was deemed clinically acceptable.
In addition to in vitro studies, a small clinical trial [25] included eight patients with spontaneous intracerebral hemorrhage (three intraventricular and five intracerebral). The study involved placing a drainage catheter and an ultrasound microcatheter into the hematoma and injecting alteplase. The mean percent volume reduction of intracerebral hemorrhage and intraventricular hemorrhage was 59 ± 5% and 45.1 ± 13%, respectively. No intracranial infections or significant rebleeding events occurred. A comparison between patients treated with alteplase alone and those treated with ultrasound plus alteplase revealed that blood clots dissolved faster in the latter group. While this study presented alternative methods for ultrasound-assisted lysis of intracerebral blood clots, it acknowledged the limitations associated with ultrasound microcatheter instrument and the invasive nature of ultrasound microcatheter placement in the brain, making its clinical practicality and safety lower compared to extracorporeal ultrasound.
Limitations
The study has several limitations that should be considered. First, the use of a 37°C thermostatic water bath may not fully replicate the complex pathophysiological environment present in the human brain. The in vitro nature of the experimental setup may not capture all the dynamic factors involved in spontaneous intracerebral hemorrhage in living organisms. Second, patients with spontaneous intracerebral hemorrhage often present with underlying diseases such as hyperlipidemia and diabetes. The use of bovine whole blood may not entirely replicate the diverse blood components and biochemical profile found in patients with these comorbidities. Third, while temperature measurements around the blood clot were taken, the study was unable to assess secondary brain damage, including the potential for rebleeding and edema around the blood clot. The limitations of in vitro experiments constrain the ability to replicate the full spectrum of clinical scenarios and outcomes associated with spontaneous intracerebral hemorrhage. Fourth, since only one ultrasonic frequency and duration were used in our experiment, further studies are needed to determine the most suitable frequency and duration for promoting blood clot lysis.
These limitations highlight the need for caution when extrapolating the findings of the study to the clinical setting. Future research involving animal models or clinical trials would provide a more comprehensive understanding of the potential applications and limitations of ultrasound-assisted blood clot lysis in patients with spontaneous intracerebral hemorrhage.
Conclusions
These findings suggest that the combined application of ultrasound and urokinase effectively enhances blood clot lysis in an in vitro model of spontaneous intracerebral hemorrhage. The observed temperature variations indicate a controlled and manageable thermal effect, supporting the safety and feasibility of this combined approach. However, it is crucial to acknowledge that these results are based on in vitro experiments, and further validation through animal studies and clinical trials is essential to ascertain the practical applicability and safety of this therapeutic strategy in a clinical setting.
Supporting information
S1 Checklist.
https://doi.org/10.1371/journal.pone.0304398.s001
(DOCX)
Citation: Xu L, Yang Q, Gong J, Wang J, Xiong W, Liu L, et al. (2024) Ultrasound combined with urokinase under key-shaped bone window enhances blood clot lysis in an in vitro model of spontaneous intracerebral hemorrhage. PLoS ONE 19(5): e0304398. https://doi.org/10.1371/journal.pone.0304398
About the Authors:
Lei Xu
Contributed equally to this work with: Lei Xu, Qiang Yang
Roles: Conceptualization, Investigation, Project administration
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
ORICD: https://orcid.org/0000-0001-5164-9684
Qiang Yang
Contributed equally to this work with: Lei Xu, Qiang Yang
Roles: Data curation, Formal analysis, Methodology
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Jian Gong
Roles: Writing – original draft
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Jia Wang
Roles: Data curation, Software
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Weiming Xiong
Roles: Writing – original draft
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Liu Liu
Roles: Data curation, Software
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Yang Liu
Roles: Writing – original draft
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Weiduo Zhou
Roles: Writing – review & editing
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Chao Sun
Roles: Data curation, Software
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Yidan Liang
Roles: Writing – review & editing
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Yanglingxi Wang
Roles: Data curation, Software
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Yi Xiang
Roles: Writing – review & editing
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Yongbing Deng
Roles: Supervision
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
Min Cui
Roles: Conceptualization, Supervision
E-mail: [email protected]
Affiliations: Department of Neurosurgery, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China, Chongqing Key Laboratory of Emergency Medicine, Chongqing Emergency Medical Center, Chongqing University Central Hospital, Chongqing, 400010, China
ORICD: https://orcid.org/0009-0008-5187-9410
1. Greenberg SM, Ziai WC, Cordonnier C, et al. 2022 Guideline for the Management of Patients With Spontaneous Intracerebral Hemorrhage: A Guideline From the American Heart Association/American Stroke Association. Stroke. 2022;53(7):e282–e361. pmid:35579034
2. Mendelow AD, Gregson BA, Fernandes HM, et al. Early surgery versus initial conservative treatment in patients with spontaneous supratentorial intracerebral haematomas in the International Surgical Trial in Intracerebral Haemorrhage (STICH): a randomised trial. Lancet. 2005;365(9457):387–397. pmid:15680453
3. Mendelow AD, Gregson BA, Rowan EN, et al. Early surgery versus initial conservative treatment in patients with spontaneous supratentorial lobar intracerebral haematomas (STICH II): a randomised trial [published correction appears in Lancet. 2013 Aug 3;382(9890):396] [published correction appears in Lancet. 2021 Sep 18;398(10305):1042]. Lancet. 2013;382(9890):397–408. pmid:23726393
4. Morgan T, Zuccarello M, Narayan R, Keyl P, Lane K, Hanley D. Preliminary findings of the minimally-invasive surgery plus rtPA for intracerebral hemorrhage evacuation (MISTIE) clinical trial. Acta Neurochir Suppl. 2008;105:147–151. pmid:19066101
5. Hanley DF, Thompson RE, Muschelli J, et al. Safety and efficacy of minimally invasive surgery plus alteplase in intracerebral haemorrhage evacuation (MISTIE): a randomised, controlled, open-label, phase 2 trial. Lancet Neurol. 2016;15(12):1228–1237. pmid:27751554
6. Hanley DF, Thompson RE, Rosenblum M, et al. Efficacy and safety of minimally invasive surgery with thrombolysis in intracerebral haemorrhage evacuation (MISTIE III): a randomised, controlled, open-label, blinded endpoint phase 3 trial [published correction appears in Lancet. 2019 Apr 20;393(10181):1596]. Lancet. 2019;393(10175):1021–1032. pmid:30739747
7. Anderson CS. Stroke advances in 2023: a new horizon for the management of intracerebral haemorrhage. Lancet Neurol. 2024;23(1):12–13. pmid:38101883
8. Li X, Du H, Song Z, et al. Efficacy and safety of sonothrombolysis in patients with acute ischemic stroke: A systematic review and meta-analysis. J Neurol Sci. 2020;416:116998. pmid:32623143
9. Tsivgoulis G, Katsanos AH, Eggers J, et al. Sonothrombolysis in Patients With Acute Ischemic Stroke With Large Vessel Occlusion: An Individual Patient Data Meta-Analysis. Stroke. 2021;52(12):3786–3795. pmid:34428930
10. Farrokhi M, Khurshid M, Mohammadi S, et al. Comparison of ultrasound-accelerated versus conventional catheter-directed thrombolysis for deep vein thrombosis: A systematic review and meta-analysis. Vascular. 2022;30(2):365–374. pmid:33900841
11. Inzunza-Cervantes G, Velarde-Pérez D, Saldaña-García JH, Espinoza-Escobar G, Velázquez-Mejía FJ. Trombólisis acelerada por ultrasonido. Experiencia inicial en pacientes con contraindicación para trombólisis sistémica [Ultrasound-accelerated thrombolysis. Initial experience in patients with contraindications to systemic thrombolysis]. Rev Med Inst Mex Seguro Soc. 2023;61(3):370–379. pmid:37216692.
12. Masomi-Bornwasser J, Fabrig O, Krenzlin H, et al. Systematic Analysis of Combined Thrombolysis Using Ultrasound and Different Fibrinolytic Drugs in an in Vitro Clot Model of Intracerebral Hemorrhage. Ultrasound Med Biol. 2021;47(5):1334–1342. pmid:33549380
13. Masomi-Bornwasser J, Winter P, Neulen A, et al. Doppler sonography enhances rtPA-induced fibrinolysis in an in vitro clot model of spontaneous intracerebral hemorrhages. PLoS One. 2019;14(1):e0210810. Published 2019 Jan 17. pmid:30653589
14. Wang Z, Komatsu T, Mitsumura H, et al. An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull. Ultrasonics. 2017;77:168–175. pmid:28242510
15. Masomi-Bornwasser J, Winter P, Müller-Werkmeister H, et al. Combination of ultrasound and rtPA enhances fibrinolysis in an In Vitro clot system [published correction appears in PLoS One. 2018 Jul 5;13(7):e0200456]. PLoS One. 2017;12(11):e0188131. Published 2017 Nov 16. pmid:29145482
16. Keric N, Döbel M, Krenzlin H, et al. Comparative analysis of fibrinolytic properties of Alteplase, Tenecteplase and Urokinase in an in vitro clot model of intracerebral haemorrhage [published correction appears in J Stroke Cerebrovasc Dis. 2020 Dec;29(12):105338]. J Stroke Cerebrovasc Dis. 2020;29(9):105073. pmid:32807475
17. Keric N, Masomi-Bornwasser J, Müller-Werkmeister H, et al. Optimization of Catheter Based rtPA Thrombolysis in a Novel In Vitro Clot Model for Intracerebral Hemorrhage. Biomed Res Int. 2017;2017:5472936. pmid:28459065
18. Tang J, Tang J, Zhu Q, et al. A minimally invasive strategy to evacuate hematoma by synergy of an improved ultrasonic horn with urokinase: An in vitro study. Med Phys. 2022;49(3):1333–1343. pmid:35018646
19. Yan L, Zhou X, Zheng Y, et al. Research progress in ultrasound use for the diagnosis and treatment of cerebrovascular diseases. Clinics (Sao Paulo). 2019;74:e715. Published 2019 Mar 7. pmid:30864640
20. Zafar M, Memon RS, Mussa M, Merchant R, Khurshid A, Khosa F. Does the administration of sonothrombolysis along with tissue plasminogen activator improve outcomes in acute ischemic stroke? A systematic review and meta-analysis. J Thromb Thrombolysis. 2019;48(2):203–208. pmid:31214876
21. Papadopoulos N, Kyriacou PA, Damianou C. Review of Protocols Used in Ultrasound Thrombolysis. J Stroke Cerebrovasc Dis. 2017;26(11):2447–2469. pmid:28882659
22. Amaral-Silva A, Piñeiro S, Molina CA. Sonothrombolysis for the treatment of acute stroke: current concepts and future directions. Expert Rev Neurother. 2011;11(2):265–273. pmid:21306213
23. Aaron S, Mani S, Prabhakar AT, et al. Sonothrombolysis for acute ischemic stroke—Break on through to the other side. Neurol India. 2017;65(1):52–57. pmid:28084238
24. Goel L, Jiang X. Advances in Sonothrombolysis Techniques Using Piezoelectric Transducers. Sensors (Basel). 2020;20(5):1288. Published 2020 Feb 27. pmid:32120902
25. Newell DW, Shah MM, Wilcox R, et al. Minimally invasive evacuation of spontaneous intracerebral hemorrhage using sonothrombolysis. J Neurosurg. 2011;115(3):592–601. pmid:21663412
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
© 2024 Xu et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Objective
Minimally invasive surgery for spontaneous intracerebral hemorrhage is impeded by inadequate lysis of the target blood clot. Ultrasound is thought to expedite intravascular thrombolysis, thereby facilitating vascular recanalization. However, the impact of ultrasound on intracerebral blood clot lysis remains uncertain. This study aimed to explore the feasibility of combining ultrasound with urokinase to enhance blood clot lysis in an in vitro model of spontaneous intracerebral hemorrhage.
Methods
The blood clots were divided into four groups: control group, ultrasound group, urokinase group, and ultrasound + urokinase group. Using our experimental setup, which included a key-shaped bone window, we simulated a minimally invasive puncture and drainage procedure for spontaneous intracerebral hemorrhage. The blood clot was then irradiated using ultrasound. Blood clot lysis was assessed by weighing the blood clot before and after the experiment. Potential adverse effects were evaluated by measuring the temperature variation around the blood clot in the ultrasound + urokinase group.
Results
A total of 40 blood clots were observed, with 10 in each experimental group. The blood clot lysis rate in the ultrasound group, urokinase group, and ultrasound + urokinase group (24.83 ± 4.67%, 47.85 ± 7.09%, 61.13 ± 4.06%) was significantly higher than that in the control group (16.11 ± 3.42%) (p = 0.02, p < 0.001, p < 0.001). The blood clot lysis rate in the ultrasound + urokinase group (61.13 ± 4.06%) was significantly higher than that in the ultrasound group (24.83 ± 4.67%) (p < 0.001) or urokinase group (47.85 ± 7.09%) (p < 0.001). In the ultrasound + urokinase group, the mean increase in temperature around the blood clot was 0.26 ± 0.15°C, with a maximum increase of 0.38 ± 0.09°C. There was no significant difference in the increase in temperature regarding the main effect of time interval (F = 0.705, p = 0.620), the main effect of distance (F = 0.788, p = 0.563), or the multiplication interaction between time interval and distance (F = 1.100, p = 0.342).
Conclusions
Our study provides evidence supporting the enhancement of blood clot lysis in an in vitro model of spontaneous intracerebral hemorrhage through the combined use of ultrasound and urokinase. Further animal experiments are necessary to validate the experimental methods and results.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer