Full text

Turn on search term navigation

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Three-dimensional echocardiography (3D ECHO) and magnetic resonance (MR) imaging are frequently used in patients and animals to evaluate heart functions. Inverse finite element (FE) modeling is increasingly applied to MR images to quantify left ventricular (LV) function and estimate myocardial contractility and other cardiac biomarkers. It remains unclear, however, as to whether myocardial contractility derived from the inverse FE model based on 3D ECHO images is comparable to that derived from MR images. To address this issue, we developed a subject-specific inverse FE model based on 3D ECHO and MR images acquired from seven healthy swine models to investigate if there are differences in myocardial contractility and LV geometrical features derived using these two imaging modalities. We showed that end-systolic and end-diastolic volumes derived from 3D ECHO images are comparable to those derived from MR images (R2=0.805 and 0.969, respectively). As a result, ejection fraction from 3D ECHO and MR images are linearly correlated (R2=0.977) with the limit of agreement (LOA) ranging from −17.95% to 45.89%. Using an inverse FE modeling to fit pressure and volume waveforms in subject-specific LV geometry reconstructed from 3D ECHO and MR images, we found that myocardial contractility derived from these two imaging modalities are linearly correlated with an R2 value of 0.989, a gradient of 0.895, and LOA ranging from −6.11% to 36.66%. This finding supports using 3D ECHO images in image-based inverse FE modeling to estimate myocardial contractility.

Details

Title
Comparison of Left Ventricular Function Derived from Subject-Specific Inverse Finite Element Modeling Based on 3D ECHO and Magnetic Resonance Images
Author
Fan, Lei 1 ; Choy, Jenny S 2 ; Cai, Chenghan 1 ; Teague, Shawn D 3 ; Guccione, Julius 4 ; Lee, Lik Chuan 5 ; Kassab, Ghassan S 2 

 Joint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI 53233, USA; [email protected] (L.F.); [email protected] (C.C.) 
 California Medical Innovations Institute, San Diego, CA 92121, USA; [email protected] 
 Department of Radiology, National Jewish Health, Denver, CO 80206, USA; [email protected] 
 Department of Surgery, University of California at San Francisco, San Francisco, CA 94143, USA; [email protected] 
 Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824, USA; [email protected] 
First page
735
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
23065354
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3084741509
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.