Abstract

Accurate long-term forecasts of aggregate energy load profiles are crucial for effective energy system planning at regional and national scales. This study aims to validate PROFet, a flexible load profile modeling tool. PROFet forecasts weather-dependent heating and electrical load profiles at an hourly resolution for both residential and non-residential buildings connected to district heating systems. Given that the tool’s accuracy for residential buildings has been demonstrated in previous studies, further validation is needed for non-residential buildings. To achieve this, our study evaluates PROFet’s extrapolation performance using an out-of-sample test dataset from Trondheim municipality. The results show that PROFet accurately forecasts the hourly heating load during the space-heating season but is less accurate during periods when domestic hot water needs dominate. The tool exhibits nearly identical performance across the three cases, except for efficient kindergartens, where the estimation accuracy is lower.

Details

Title
Validation of the Energy Demand Load Profile Estimator “PROFet” for Trondheim Non-residential Buildings
Author
Mohammadabadi, Abolfazl; Sartori, Igor; Georges, Laurent
Section
Validation, Calibration and Uncertainty
Publication year
2024
Publication date
2024
Publisher
EDP Sciences
ISSN
25550403
e-ISSN
22671242
Source type
Conference Paper
Language of publication
English
ProQuest document ID
3094485506
Copyright
© 2024. This work is licensed under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and conditions, you may use this content in accordance with the terms of the License.