It appears you don't have support to open PDFs in this web browser. To view this file, Open with your PDF reader
Abstract
Background
To investigate the peripapillary retinal nerve fibre layer (RNFL) thickness changes and analyse factors associated with visual recovery of G11778A Leber hereditary optic neuropathy (LHON) patients.
Methods
Patients diagnosed with G11778A LHON between July 2017 and December 2020 in Tongji hospital were included in this follow-up study. Patients were grouped according to disease duration. Variations in the RNFL thickness in each quadrant at different disease stages were characterised using optical coherence tomography. According to the absence or presence of significant visual acuity improvements, LHON patients of disease duration ≥ 6 months were divided into two groups. A bivariate logistic regression model was constructed to analyse the potential factors associated with spontaneous visual recovery.
Results
This study included 56 G11778A LHON patients (112 eyes) and 25 healthy controls (50 eyes), with a mean follow-up of 5.25 ± 1.42 months. All quadrants and mean RNFL thicknesses of LHON patients first increased and then decreased, except for the temporal RNFL. As the disease progressed, RNFL thinning slowed; however, gradual RNFL thinning occurred. Logistic regression revealed that baseline best corrected visual acuity was related to spontaneous visual recovery of LHON patients with disease duration ≥ 6 months.
Conclusion
The pattern of RNFL involvement could be helpful in the differential diagnosis of LHON and other optic neuropathies. LHON patients with better vision are more likely to experience some degree of spontaneous visual acuity recovery after the subacute phase.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer