© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Background: Acute right ventricular failure is a critical complication after left ventricular assist device (LVAD) implantation, often managed with a temporary paracorporeal right ventricular assist device (RVAD). This study examined three extracorporeal life support (ECLS) systems regarding mortality, bleeding complications, and intensive care unit (ICU) stay duration. Methods: This monocentric, retrospective case–control study included all patients receiving LVAD with paracorporeal RVAD between 2009 and 2020. Three patient groups were formed: CentrimagTM (A), CardiohelpTM (B), and DeltastreamTM (C). Results: A total of 245 patients were included. Preoperative parameters were similar between the CentrimagTM and DeltastreamTM groups, but CardiohelpTM patients had worse Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Scores (A: 1.7 ± 0.8, B: 1.36 ± 0.5, C: 1.9 ± 0.9; p < 0.05). In-hospital death rates were A: 61 (41.8%), B: 15 (32.6%), C: 29 (54.7%); p < 0.05, and reoperation due to bleeding rates were A: 32 (21.9%), B: 8 (17.4%), C: 25 (47.2%); p < 0.05, with the DeltastreamTM group showing the highest rates. This group also had increased thrombocyte consumption and prolonged ICU stays. Conclusions: Temporary RVADs lead to bleeding complications, affecting patient outcomes. The DeltastreamTM group had significantly higher bleeding complications, likely due to high pump revolution rates and thrombocyte decline. Due to the study’s retrospective nature and complex patient profiles, these interesting findings should be validated in future studies.

Details

Title
Different ECLS Pump Configurations for Temporary Right Ventricular Assist Device in LVAD Patients: A Retrospective Case–Control Study
Author
Opacic, Dragan 1   VIAFID ORCID Logo  ; Klüß, Christian 2   VIAFID ORCID Logo  ; Radakovic, Darko 1   VIAFID ORCID Logo  ; El-Hachem, Georges 1   VIAFID ORCID Logo  ; Becker, Tobias 2 ; Rudloff, Markus 2 ; Lauenroth, Volker 2 ; Marcus-André Deutsch 1   VIAFID ORCID Logo  ; Velasquez-Silva, Claudio 1   VIAFID ORCID Logo  ; Fox, Henrik 1   VIAFID ORCID Logo  ; Schramm, René 1 ; Morshuis, Michiel 1 ; Gummert, Jan F 1 ; Rojas, Sebastian V 1   VIAFID ORCID Logo 

 Clinic for Thoracic and Cardiovascular Surgery, Heart and Diabetes Centre North Rhine Westphalia, 32545 Bad Oeynhausen, Germany; Faculty of Medicine, Ruhr University Bochum, 44801 Bochum, Germany; Medical Faculty OWL, Bielefeld University, 33604 Bielefeld, Germany 
 Clinic for Thoracic and Cardiovascular Surgery, Heart and Diabetes Centre North Rhine Westphalia, 32545 Bad Oeynhausen, Germany 
First page
1274
Publication year
2024
Publication date
2024
Publisher
MDPI AG
e-ISSN
20751729
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
3120677578
Copyright
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.