Abstract
Electrocardiography (ECG) and photoplethysmography (PPG) are non-invasive methods used to quantify signals originating from the cardiovascular system. Although there is a strong correlation between the cycles of the two measures, the correlation between the waveforms has received little attention in research. Measuring the PPG is significantly simpler and more convenient compared to the ECG measure. Recent research has demonstrated that PPG signals can be utilized to rebuild the ECG signals, suggesting that healthcare professionals might acquire a comprehensive comprehension of patients' cardiovascular well-being by only measuring PPG. With the advancement of artificial intelligence, the deep learning model has made significant progress in reconstructing ECG signals from PPG signals. However, the quality of the reconstructed ECG signal is still in need of more enhancement. In order to enhance the quality of the reconstructed ECG signal, we propose an innovative hybrid attention-based bidirectional recurrent neural network (Bi-RNN) that incorporates a dilated convolutional neural network technique for the purpose of reconstructing ECG signals from PPG signals. This addresses issues that occur when standard dilated CNN (DCNN) models neglect the link between circumstances and dispersion of gradients. The suggested approach maximizes the utilization of the DCNN and Bi-RNN unit design to provide fusion features. In order to ensure the model's resilience to deformation, it is imperative to initially extract spatial properties utilizing convolutional neural networks (CNNs). Once we have obtained geographic data, we employ BiLSTM to extract temporal features. The proposed model is so-called hybrid attention-based CNN and BiLSTM (HA-CNN-BiLSTM). BiLSTM mitigates the issues of gradient vanishing and exploding while maintaining accuracy. To showcase the advantages of the suggested model, we conduct a comparison between HA-CNN-BiLSTM and each separate state-of-the-art method. The simulation results indicated that the proposed method yielded superior root mean square error (RMSE) when reconstructing the ECG signal across different optimizers. The results also demonstrated that the proposed method results in the lowest RMSE with SGDM optimizer which is 0.031.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Details

1 Aswan University, Faculty of Engineering, Aswan, Egypt (GRID:grid.417764.7) (ISNI:0000 0004 4699 3028); Luxor Higher Institute of Engineering and Technology, Department of Electronics and Communications, Luxor, Egypt (GRID:grid.417764.7)
2 Aswan University, Faculty of Engineering, Aswan, Egypt (GRID:grid.417764.7) (ISNI:0000 0004 4699 3028)
3 Assiut University, Department of Electrical Engineering, Faculty of Engineering, Assiut, Egypt (GRID:grid.252487.e) (ISNI:0000 0000 8632 679X); Sphinx University, Faculty of Engineering, Assiut, Egypt (GRID:grid.252487.e) (ISNI:0000 0005 0813 7834)